i Single Station Wa ter proof Timer Installation and Programming Guide Single Station Wa ter proof Timer Installation and Programming Guide Features • Up to four irrigation cycles per day • Easy installation and programming • Battery powered • Waterproof and weather resistant 7 1 2 3 4 5 6 S S M T W T F 1234 AM PM 24 Part No.
ii ii Table of Contents P arts Identication ................................................................................................................ 1 Battery Installation ....................................................................
1 1 1 2 2 3 3 5 5 4 4 Parts Identification Congratulations on purchasing a T oro ® S ingle Station Timer (SST). Y ou have a po werful but easy to use battery-operated valve controller that ts most common valves*. e SST comes with a DC-Latching solenoid attached, making connecting to your valve simple and easy .
2 Battery Installation Battery installation should take place before attaching the SST to a valve. If you hav e already attached the SST to a valve, you will need to detach it. 1. Place the SST face down. e battery compartment is sealed with four (4) screws.
3 * e included DC-latching solenoid is not compatible with Hunter® brand valv es. Use of the SST with Hunter valv es requires a H unter DC-latching solenoid (sold separately). Hunter is a trademark of H unter Industries. Attaching the SST to a Valve e SST includes a pre-wired DC-latching solenoid*.
4 LCD Overview 1. Low battery indicator . If the icon is ashing, the battery is low and should be changed. If the icon is solid, the controller will not operate. Replace the battery . 2. Set current time indicator 3. Digital display . Shows the curr ent time or run-time during programming.
5 Programming the SST Ev er y programming operation begins by pr essing the MODE button. A long press (>2 seconds) turns the controller o. A short press (<2 seconds) advances the controller through the dierent pr ogramming functions in the order that follows.
6 Set Clock 1. e icon shows. e hour number ( 12:00 or 00:00 depending on mode chosen above) will ash. P ress or to cycle to the correct hour . If in AM/PM mode, AM or PM will be set in Step 5. 2. Pr ess to enter selection. 3. e minute number ( 00:00 ) will ash.
7 Set Run Time 1. e icon shows. e default run time per program is 10 minutes. 2. Pr ess or to adjust the hours. Pr ess . 3. Pr ess or to adjust the minutes. 4. Pr ess once to set and advance to the next programming option. Set Start Time is setting has 4 possible start times to allow watering up to four times a day .
8 Pr ess or to cycle to the correct start time hour . Press to set. 4. e minute number ( 00:00 ) will ash. P ress or to advance to the correct start time minute.
9 day , irrigation will run past midnight. Off Mode OFF mode turns o the watering program. Active Day bo xes disappear . e time display and “OFF” toggle back and forth on the display . e current day ashes. 1. Pr ess for >2 seconds to activate OFF mode.
10 Manual Operation 1. T o turn on the valve manually , press and together . 2. e valve will run for the programmed run-time (page 8). 3. T o prematurely ST OP a manual operation, press and together . Stopping the Current Irrigation Cycle It is possible to stop the curr ent irrigation cycle.
11 Installing a Rain Sensor It is possible to connect a wir ed T oro® RainS ensor™ to the SST . Other normally closed sensors can be installed as well. Wir ed polarity is not observed for the sensor . 1. Cut the wire loop (y ellow) from the SST . (See F igure 1.
12 The Reset Button e Reset button resets the controller to erase all watering programs. 1. Remov e the batter y compartment lid and battery . 2. In the upper left corner , you will see a black button with a refresh symbol. U sing a screwdriver , press that button.
13 Troubleshooting Guide Pr oblem P ossible Cause Solution Controller does not display anything. 1. e battery is dead. 2. Controller is in Sleep mode. 1. Install a new 9V battery . 2. Press MODE to activate scr een. W ater does not turn ON. 1. Faulty contr ol valve wire connections.
14 The T oro Company and its afliate, T oro W arranty Company, pursuant to an agreement between them, jointly warrants, to the owner , against defects in material and workmanship for a period of two years from the date of purchase.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Toro 53887 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Toro 53887 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Toro 53887 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Toro 53887 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Toro 53887, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Toro 53887.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Toro 53887. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Toro 53887 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.