Manuale d’uso / di manutenzione del prodotto TAS5601 del fabbricante Texas Instruments
Vai alla pagina of 31
User's Guide SLOU219 – February 2008 TAS5601 Digital Power Amplifier With MC5601 Modulator Kit This manual describes the operation of the TAS5601EVM evaluation module from Texas Instruments. Contents 1 Purpose of This Document .................
www.ti.com 3 Related Documentation from Texas Instruments ...................................................................... 23 2 TAS5601 Digital Power Amplifier With MC5601 Modulator Kit SLOU219 .
www.ti.com 1 Purpose of This Document 2 Overview Purpose of This Document This user's guide describes how to use the TAS5601 evaluation module (EVM) to evaluate performance of the TAS5601 device. The document contains the following. • Details of how to properly set up an MC5601 modulator kit.
www.ti.com 2CH AnalogInput fromothersource/ Digitalout SPDIF/ Optical,Coax T AS5601EVM Left Right I2S MC5601 2.1 TAS5601EVM and MC5601 Features Overview Figure 2. EVM Controller Board (MC5601) The TAS5601EVM is a complete 2-channel digital audio amplifier system.
www.ti.com 3 Installation 3.1 Software Installation 3.2 EVM Installation 3.2.1 PSU Interface 3.2.2 Loudspeaker Connectors Installation • Access to control signal gain and data format through EVM-software graphic user interface (GUI) This section describes the software and EVM installation.
www.ti.com 3.2.3 USB Interface 3.2.4 Digital Audio Interface SPDIF (J1/OPTO) 3.2.5 ADC Interface 3.2.6 Board Power-Up General Guidelines Installation • Connect the left speaker wires to the corresponding metal binding posts marked J2 and J4 on the TAS5601EVM board.
www.ti.com 4 Using the EVM Software 4.1 Getting Started 4.2 Setup Tab Using the EVM Software The EVM software provides access to the TAS5706 configuration and status registers through a GUI window with 7 tabs for the various EVM parameters. Open the zip file (.
www.ti.com 4.2.1 All Channel Shutdown 4.2.2 Advanced Features : EQ and DRC 4.2.2.1 EQ Loading and Viewing 4.2.2.2 DRC Coefficient Loading Using the EVM Software Figure 5. Volume Tab System comes up with all channel shut down asserted. To exit All Channel Shutdown , select Setup Tab, unselect All Channel Shutdown .
www.ti.com Using the EVM Software Figure 6. EQ Viewer Tab Figure 7. DRC Viewer Tab SLOU219 – February 2008 TAS5601 Digital Power Amplifier With MC5601 Modulator Kit 9 Submit Documentation Feedback.
www.ti.com 4.2.3 EQC/DRC Demo 4.2.4 I 2 C Tab Using the EVM Software This tab is used to compare different settings. Multiple EQ files can be loaded and switched back and forth for listening purposes to select the golden filters. Figure 8. EQ/DRC Demo Tab Clicking on the I 2 C Interface tab displays the window shown in Figure 9 .
www.ti.com 4.2.4.1 I 2 C Writes and Reads Using the EVM Software Data can be written to or read from the device. Single- or multiple-byte write/read is determined by the subaddress. If less than 0x20, single-byte access is required. Otherwise, multiple-byte access is used.
www.ti.com 4.3 Volume Tab Using the EVM Software Select the Volume tab. Unmute the Master volume. Click on the 0 db button. Figure 11. Volume Control Tab TAS5601 Digital Power Amplifier With MC5601 Mo.
www.ti.com 5 EQ/DRC Tool Installation 5.1 TI ALE Guide for TAS570x 5.1.1 Overview 5.1.2 Select Device EQ/DRC Tool Installation If you want to use the Texas Instruments ALE tool to create filters for the EQ and DRC parameters, unzip the ale.zip file from the ALE directory located on the provided compact disc into your C:USERDATA directory.
www.ti.com 5.2 Edit EQ Filter EQ/DRC Tool Installation Click on Edit pulldown menu, and select Edit Filter Parameters as shown in the following illustration. An EQ Filter dialog box appears as shown in the following illustration. Users then enter EQ-related data.
www.ti.com 5.2.1 Display the Graph EQ/DRC Tool Installation For channels 1 and 2, users can create up to seven EQ data sets. For channel 6, users can create up to four EQ data sets. See the TAS570x data sheet for detailed technical information related to filters.
www.ti.com 5.2.2 Generate EQ Filter Data EQ/DRC Tool Installation Click on the Edit pulldown menu, and select Generate Device Data as shown in the following illustration. A Select Channel dialog box appears as shown in the following illustration. Users can select to which channel the EQ filter data is applied.
www.ti.com 5.2.3 Save EQ Data to File 5.3 Edit and Generate DRC Data EQ/DRC Tool Installation Click on the File pulldown menu, and select Save Device Program Data J as shown in the following illustration. Click on the pulldown menu, and select Dynamic Range Compression for TAS570X as shown in the following illustration.
www.ti.com 5.3.1 Edit and Generate Alpha Filter Data EQ/DRC Tool Installation To see the drawing with the new data, click on the Apply button. The DRC combination box allows users to select to which DRC, 1 or 2, the data is applied. To save the data for the selected DRC, 1 or 2, click on the Save Data button.
www.ti.com 5.3.2 Save DRC Data to File 5.4 Save EQ/DRC/Alpha Data to File EQ/DRC Tool Installation When finished generating Alpha Filter data for the DRCs, the user clicks the OK button to close the dialog. To save the DRC data only, click the File pulldown menu, and select the Save As .
www.ti.com 6 Jumpers and Control Utilities 6.1 Switches Jumpers and Control Utilities Reset is an active-low function. Pressing the master reset switch (S2) resets the TAS5601.
www.ti.com 7 Board Layouts, Bill of Materials, and Schematics 7.1 TAS5601EVM Board Layouts Board Layouts, Bill of Materials, and Schematics Figure 12. Top Silk Screen View Figure 13.
www.ti.com 7.2 Bill of Materials 7.3 Schematics Board Layouts, Bill of Materials, and Schematics Table 2. Bill of Materials for TAS5601EVM TI SEMICONDUCTORS Item Description Ref Des Qty MFG MFG:Part No. Vendor Vendor: Part No. Alt. Part No. 1 80W 4 CH Power Amp, HTSSOP56-DCA PA1 1 Texas TAS5601DCA Texas TAS5601DCA No Alt.
of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Prin.
of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: NC MC5601.
of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: H H 24Bit/MSB/I2S FMT1 FMT0 NC MC5601.
of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: MC5601.
of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: FROM FROM FROM FROM MUTE FAULT VALID PGND PGND MC5601.
of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: of Filename: Mod: PCB Rev: Sheet Save Date: CX Schematic Rev: Design Team: Drawn By: TI Print Date PROJECT: A0 SDIN1 MCLK TO ADC JP4 JP3 JP8 JP7 3.
www.ti.com 8 Related Documentation From Texas Instruments Related Documentation From Texas Instruments Table 3 contains a list of data manuals that have detailed descriptions of the integrated circuits and other components used in the design of the TAS5601EVM.
EVALUATION BOARD/KIT IMPORTANT NOTICE Texas Instruments (TI) provides the enclosed product(s) under the following conditions: This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use.
IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Texas Instruments TAS5601 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Texas Instruments TAS5601 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Texas Instruments TAS5601 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Texas Instruments TAS5601 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Texas Instruments TAS5601, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Texas Instruments TAS5601.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Texas Instruments TAS5601. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Texas Instruments TAS5601 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.