March 2004 Mixed-Signal Products User ’ s Guide SLOU166A.
IMPORT ANT NOTICE T exas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.
EVM IMPORT ANT NOTICE T exas Instruments (TI) provides the enclosed product(s) under the following conditions: This evaluation kit being sold by TI is intended for use for ENGINEERING DEVELOPMENT OR EV ALUA TION PURPOSES ONL Y and is not considered by TI to be fit for commercial use.
EVM W ARNINGS AND RESTRICTIONS It is important to operate this EVM within the supply voltage range of 2.5 V to 5.5 V . Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM.
Information About Cautions and Warnings iii Preface Read This First Information About Cautions and Warnings This book may contain cautions and warnings. This is an example of a caution statement. A caution statement describes a situation that could potentially damage your software or equipment.
FCC Warning iv FCC Warning This equipment is intended for use in a laboratory test environment only . It generates, uses, and can radiate radio frequency energy and has not been tested for compliance .
Contents v Contents 1 Introduction 1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Feature Highlights 1-2 . . . . . . . . . . . . . . . . . . . . . . . .
Contents vi.
1-1 Introduction Introduction This chapter provides an overview of the T exas Instruments (TI) TP A2010D1 NanoFree WCSP audio amplifier evaluation module (TP A2010D1YZF EVM). It includes a list of EVM features, a brief illustrated description of the module, and a list of EVM specifications.
Feature Highlights 1-2 1.1 Feature Highlights The TI TP A2010D1 audio amplifier evaluation module and the TI Plug-N-Play audio amplifier evaluation platform include the following features: - TP A2010D1 Low-V oltage Audio Power Amplifier Evaluation Module J 1.
Description 1-3 Introduction 1.2 Description The TP A2010D1 audio power amplifier evaluation module is a complete, low-power single-channel audio power amplifier .
1-4.
2-1 Operation Operation Follow the steps in this chapter to prepare the TP A2010D1 audio amplifier EVM for use. Using the TP A2010D1 EVM with the TI Plug-N-Play audio amplifier evaluation platform is a quick and easy way to connect power , signal and control inputs, and signal outputs to the EVM, using standard connectors.
Precautions 2-2 2.1 Precautions Power Supply Input Polarity and Maximum V oltage Always ensure that the polarity and voltage of the external power connected t o V CC power input connector J1, J2, and/or V DD power input connector J6 are correct.
Quick Start List for Platform 2-3 Operation 2.2 Quick Start List for Platform Follow these steps when using the TP A2010D1 EVM with the TI Plug-N-Play audio amplifier evaluation platform (see the platform user ’s guide, SLOU01 1, for additional details).
Quick Start List for Stand-Alone 2-4 2.3 Quick Start List for Stand-Alone Follow these steps to use the TP A2010D1 EVM stand-alone or when connecting it into existing circuits or equipment.
References 2-5 Operation 2.4 References 2.4.1 TP A2010D1 EVM Connected for Stereo BTL Output Figure 2−2. TP A2010D1 EVM Connected for Stereo BTL Output 5 VDC Right Audio Input (Right) Audio Input (L.
TP A2010D1 Audio Power Amplifier Evaluation Module Parts List 2-6 2.4.2 TP A2010D1 EVM Schematic Diagram Figure 2−3. TP A2010D1 EVM Schematic Diagram IN+ C2 0.22 µ F R2 150 k Ω (1) 0.22 µ F C1 150 k Ω (1) R1 SHUTDOWN S1 100 k Ω R3 IN+ V DD IN− SHUTDOWN GND VO− VO+ PV DD C4 10 µ F C3 0.
TP A2010D1 EVM PCB Layers 2-7 Operation 2.4.4 TP A2010D1 EVM PCB Layers The following illustrations depict the TP A2010D1 EVM PCB layers and silk- screen. These drawings are not to scale. Gerber plots can be obtained from any TI sales office. Figure 2−4.
2-8.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Texas Instruments 2004 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Texas Instruments 2004 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Texas Instruments 2004 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Texas Instruments 2004 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Texas Instruments 2004, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Texas Instruments 2004.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Texas Instruments 2004. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Texas Instruments 2004 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.