OWNER’S MANUAL _________________ BAYTECH REMOTE POWER CONTROL UNIT FOR MODELS RPC-2 RPC-2A RPC-2 MD01 RPC-2 RDR RPC-3 RPC-3A RPC-5 BayTech Manual Publication #U140E125-03 July 1998.
ii Copyright 1998 by Bay Technical Associates, Inc. BayTech, Telplex, LaserShare, Print Master and TRAN-X are registered tradem arks of Bay Techni cal Associates, Inc. IBM, IBM PC, IBM PC/AT, IBM PC/XT are products a nd registered trademarks of International Bus iness Machines Corporation.
RPC SERIES OWNER’S M ANUAL ABOUT THIS OWNER’S M ANUAL __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ iii ABOUT THIS OWNER’S MANUAL This document provides information re quired fo r installing a nd operating y our Bay Tech equipment.
RPC SERIES OWNER’S M ANUAL ABOUT THIS OWNER’S M ANUAL __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ iv The information in this document is subject to change without notice.
v .
vi CHANGE OUTLET NAME .............................................................................. 34 RPC-3, R PC-3A, AND RPC-5 .....................................................................
vii #$ ! .
RPC SERIES OWNER’S M ANUAL INTRODUCTION TO THE RPC SE RIES __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 1 INTRODUCTION TO THE REMOTE POWER CONTRO.
RPC SERIES OWNER’S M ANUAL RPC SERIES QUICK S TART (RPC-2 AND RPC-2A) __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 2 RPC SERIES QUICK START “Quick Start” is designed for users familiar with BayTech products who need a fast setup and familiarization.
RPC SERIES OWNER’S M ANUAL RPC SERIES QUICK S TART (RPC-2 AND RPC-2A) __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 3 If the status menu fails to appear, ensure the correct cables and adapters are being used and that they are connected properl y.
RPC SERIES OWNER’S M ANUAL RPC SERIES QUICK S TART (RPC-2 AND RPC-2A) __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 4 Change Password Default password is <cr> . The maximum field length is 8 al phanumeric characte rs.
RPC SERIES OWNER’S M ANUAL RPC SERIES QUICK S TART (RPC-2 MD01 AND RPC-2 RDR) __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 5 RPC-2 MD01 AND RPC-2.
RPC SERIES OWNER’S M ANUAL RPC SERIES QUICK S TART (RPC-2 MD01 AND RPC-2 RDR) __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 6 Using the RJ04X007 (RJ-11) modular cable, connect either port labeled “LINE ” on the RPC unit to the te lco wall jack .
RPC SERIES OWNER’S M ANUAL RPC SERIES QUICK S TART (RPC-2 MD01 AND RPC-2 RDR) __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 7 Controlling Receptac.
RPC SERIES OWNER’S M ANUAL RPC SERIES QUICK S TART (RPC-3, RPC-3A, AND RPC-5) __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 8 RPC-3, R PC-3A AND R PC-5 QUICK START NOTE: The RPC-3, 3A a nd 5 are configured in a similar manne r.
RPC SERIES OWNER’S M ANUAL RPC SERIES QUICK S TART (RPC-3, RPC-3A, AND RPC-5) __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 9 RPC-3 Te l net Host Revis io n F 3.03, (C) 1998 Bay Technic al Asso ciates Unit ID: RPC3 RPC-3 Menu: 1) .
RPC SERIES OWNER’S M ANUAL RPC SERIES QUICK S TART (RPC-3, RPC-3A, AND RPC-5) __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 10 Change Password Default password is <cr>; disabled. Password is case sensitive.
RPC SERIES OWNER’S M ANUAL RPC SERIES QUICK S TART (RPC-3, RPC-3A, AND RPC-5) __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 11 Access Defaul t password is <cr>; disab led. NOTE : I f user nam e and password are disabled (d efault), outlet users will have access to all admin functions.
RPC SERIES OWNER’S M ANUAL INSTALLATION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 12 INSTALLATION UNPACKI NG Compare the unit and serial number of the equipment you received to the packing slip located on the outside of the box.
RPC SERIES OWNER’S M ANUAL INSTALLATION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 13 POWER CAUTION: This unit is intended for indoor use onl y . Do not install near wa ter or expose this unit to moisture.
RPC SERIES OWNER’S M ANUAL INSTALLATION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 14 POWER ON/OFF STATE Each recept acle is indi vidually controll ed by an intern al rela y .
RPC SERIES OWNER’S M ANUAL CABLING __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 15 CABLING RJ-45 CABLES AND ADAPTERS IMPORTANT: All RPC models have an RJ-45 port for connectin g to a local E IA-232 device such as a computer termin al or external modem.
RPC SERIES OWNER’S M ANUAL CABLING __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 16 The RPC R J-45 con tro l por t use s t he fol low ing sig nals : EIA- 232 R J- 45 PI N /S I GN A L DEFI N I TI ON Pin EIA- 232 Sign al Direction Descrip tion 1D T R O u t p u t +10V w hen activ ate d by D CD .
RPC SERIES OWNER’S M ANUAL CABLING __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 17 Modem Co mm unicat io ns: A modem ca n be co nnected to the EI A-232 serial port by using a 25MR J45MD-8 adapter (F ig ure 6).
RPC SERIES OWNER’S M ANUAL CABLING __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 18 IMPORTANT : Crossed R J-45 cables are required when mod ular c.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 19 DETAILED OPERATION AND CONFIGURATION The following section, “Operation and Confi guration,” provides a detailed approach to accessing, op erating, and confi guring the RPC.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 20 Using the 9FRJ45PC-1 adapter (or.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 21 Accessing Main Menu Power on the RPC unit. The following status menu appears: RPC-2 Ser ies (c) 1997 by BayTec h F2.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 22 RPC-2 Ser ies (c) 1997 by BayTec h F2.07 Circu it Bre ak er : On 1) . . . OUT LET 1 : O ff 2) .
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 23 set, the RPC requires password entr y before allowing the user to operate the RPC unit .
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 24 typing “CON FIG” to access th e configuration menu.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 25 Enter the number of the outlet y ou want to change. If y ou want to chan ge the name of Outlet 4, type the number 4 at the “Enter Request” prompt, followed b y <cr>.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 26 From the configuration menu, select #3, “Enable/Disable Confirmation.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 27 RPC-2 MD01 AND RPC-2 RDR LOCAL A.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 28 parameters are 9600 bps, 8 data bits, 1 stop bit, and no parity.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 29 OPERATION The RPC’s main menu allows y ou to monitor and control equipment attached to each of the R PC-2 RDR and RPC -2 MD01’s six receptacles.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 30 If the status menu fails to appear, ensure the correct cabl es and adapters a re being us ed and that they are connected prop erl y .
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 31 The REBOOT n command will reboot or reset equipment attached to co rresponding receptacl e(s).
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 32 RPC-2 Seri es (C) 1997 by BayTe ch F2.07 Circu it Bre ak er : On 1) . . . OUT LET 1 : O ff 2) .
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 33 Change Password From the status menu’s RPC > prompt, type CONFIG . The following menu appears: RPC > CONFIG 1) .
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 34 typing CONFIG” from the RPC > prompt to access the confi guration menu.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 35 Select #2, “Change Outlet Name,” and press <Enter.> The RPC responds: 1) .
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 36 RPC-3 AND RPC-3A and R PC-5 NOTE : The RPC-3, RPC-3A and RPC-5 are configured in a similar manner.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 37 LOCAL ACCESS Load serial port communications software. USING EIA-232 Configure host te rminal’s serial SERIAL CONNECTION communications pa rameters to matc h the RPC.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 38 established via a Telnet session from your workstation. Using a straight 10Base-T cable, conn ect the Ethernet portion the RPC Series to the network hub.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 39 In the RPC Series’s main menu,.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 40 If the ma in menu fails to appea r, ensure the correct cabl es and adapters a re being us ed and they are properl y connected.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 41 NOTE : The outlet user sees only those outlets as assigned to him by the admi n user.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 42 receptacl e(s).
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 43 Add Use r The “Add user” option is presented any time less than 8 (4 for the RPC-5) optional users are defined.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 44 Change Password IMPORTANT: If enabled, the password fun ction provides independent user access to assi gned outlets b y entering a user name and/or password.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 45 When y ou enter the current pass.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 46 Change Outlet List The outlet list dete rmines which outlets a particular user can a ccess.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 47 CONFIGURATION Configuration can be perfo rmed by the admin user only via the seri al port or the network port.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 48 address is 0.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 49 Enter the Gateway address (Example: 200.4.5.50), followed b y <cr>. The RPC resumes the c onfiguration menu Default Gateway address is 0.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 50 Login setup Togg l e option by ent eri ng nu mber, CR to ex i t. Netw ork acces s: 1).
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 51 Outlet Status Display From the Outlet Operation Configuration Menu, select #1, “Outlet Status Display.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 52 From the Outlet Configuration Menu, select #3, “Outlet Power-up Dela y .
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 53 Enter nu mber of outl et to name, CR to ex it. 1) . . . OUTLET 1 2) . . . OUTLET 2 3) .
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 54 Display Outlet User From the Outle t Operation Configuration Menu, select #5, “Display Outlet User, ” followed b y <cr>.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 55 RPC Unit Status Menu 1) . . . System 2) . . . Network In terface 3) . . . Logged Users 4) .
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 56 Netw ork Status: M e di um stat us: g ood Medium fau lts: 0 Xmit bufr errs: 0 Available send bu ffers: 2 9 Receive que ue status: open <Strik e any k ey to cont inue.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 57 Outlet St atus The following tab.
RPC SERIES OWNER’S M ANUAL DETAILED OPERATION AND CONFIGURAT ION __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 58 RPC3 > “n” refers to sel e ction n umber, as dis playe d i n Outlet Status .
RPC SERIES OWNER’S M ANUAL TECHNICAL SUPPORT ____________________________________________________________ 59 TECHNICAL SUPPORT BayTech has a staff o f applications engineers on dut y to assist y ou from 7 a.m. to 6 p.m. (CST or CDT), Monday through Friday.
RPC SERIES OWNER’S M ANUAL TECHNICAL SUPPORT ____________________________________________________________ 60 EQUIPMENT SETUP RPC Series Unit Model ____________ RPC Series Unit Serial Number __ _____.
RPC SERIES OWNER’S M ANUAL REPACKAGING, SHIPPING, AND RETURN ING TO THE FACT ORY __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 61 REPACKAGING, SHIPPING AND RETURNING TO THE FACTORY If your Ba y Tech unit needs service, up grade, or rep air, return it to BayTech.
RPC SERIES OWNER’S M ANUAL FCC RADIO FREQUENCY INTERFACE STATEM ENT __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 62 FCC RADIO FREQUENCY INTERFACE.
RPC SERIES OWNER’S M ANUAL FCC RADIO FREQUENCY INTERFACE STATEM ENT __ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ ____ ______ ____ ____ ____ ______ ____ 63 d. If the Telephone Compan y requests information on connected equipment to their lines, inform them of the following: 1.
RPC SERIES OWNER’S M ANUAL APPENDIX A _____ ____ ______ ____ ____ _____ ___ ____ ______ ____ ____ ____ ____ ______ ____ ____ ____ _____ 64 APPENDIX A SPECIFICATIONS RPC- 2 RPC- 2A RPC-2 MDO 1 RPC-2 .
RPC SERIES OWNER’S M ANUAL APPENDIX A _____ ____ ______ ____ ____ _____ ___ ____ ______ ____ ____ ____ ____ ______ ____ ____ ____ _____ 65 APPENDIX A SPECIFICATIONS (Cont.
RPC-SERIE S OWNER’S MANUAL APPENDIX B 66 APPENDIX B MODEM COMMAND SUMMARY U.S. ROBOTIC MODEMS COMMAND INTERPRETATION AT&B1 Fixed Serial Port Rate (default) AT&C1 Normal CD Operations (default) AT&D2 Normal DTR Operations (default) ATS0=1 Auto answer telephone line in 4 or fewer rings ATE0 Modem does not display ke yboard comm ands.
RPC-SERIE S OWNER’S MANUAL APPENDIX B 67 APPENDIX B MODEM COMMAND SUMMARY (Cont.) ROCKWELL CHIP SET MODEMS COMMAND INTERPRETATION ATS23=59 F ixed Serial Port Rate (def ault) AT&C1 Normal CD Oper.
RPC-SERIE S OWNER’S MANUAL APPENDIX C 68 APPENDIX C DIAGNOSTIC LED I NDICATIONS To detect hardware, cabling, or configuration problems upon initialization of power, the RPC Series go through a dia gnostic sequence. To help determine the cause of the problem, the RPC Series have a CX LED located on the front, right side of the unit.
RPC-SERIE S OWNER’S MANUAL APPENDIX D 69 APPENDIX D RPC TROUBLESHOOTING GUIDE PROBLEM SYMP TOM CAUSE SOLUTION No Menu Blank Screen Cables Adapters Parameters En sure correct cables and adapters are being used an d are connected properly . Verify serial param eters are correctly configured.
RPC-SERIE S OWNER’S MANUAL APPENDIX D 70 APPENDIX D - RPC TROUBLESHOOTING GUIDE (Cont’) PROBLEM SYMPTOM CAUSE SOLUTION Cannot access Outlet Contro l or Conf igur ation “X” i n the me nu l ine for the desi red operation Multiple Users Network user overrides s erial user.
RPC-SERIE S OWNER’S MANUAL APPENDIX D 71 APPENDIX D - RPC TROUBLESHOOTING GUIDE (Cont’) PROBLEM SYMP TOM CAUSE SOLUTION PI N G not ec ho ing request Gets request timeout Check ne t work connection.
RPC-SERIE S OWNER’S MANUAL APPENDIX E 72 APPENDIX E- DRAWINGS RPC-2.
RPC-SERIE S OWNER’S MANUAL APPENDIX E 73 APPENDIX E- DRAWINGS RPC-2A.
RPC-SERIE S OWNER’S MANUAL APPENDIX E 74 APPENDIX E- DRAWINGS RPC-2 MD01.
RPC-SERIE S OWNER’S MANUAL APPENDIX E 75 APPENDIX E- DRAWINGS RPC-2 RDR.
RPC-SERIE S OWNER’S MANUAL APPENDIX E 76 APPENDIX E- DRAWINGS RPC-3.
RPC-SERIE S OWNER’S MANUAL APPENDIX E 77 APPENDIX E- DRAWINGS RPC-3A.
RPC-SERIE S OWNER’S MANUAL APPENDIX E 78 APPENDIX E- DRAWINGS RPC3/3A/5 ETHERNET B OARD.
RPC-SERIE S OWNER’S MANUAL APPENDIX E 79 APPENDIX E- DRAWINGS RPC-5.
RPC-SERIE S OWNER’S MAP INDEX 80 INDEX A Ada pter, 2, 5, 6, 8 , 12, 16, 19, 20, 27, 28, 37 Ada p t er s, 59 Applic ations Eng ineer, iii Asynchronou s, 1 7 AT DT Comm ands, 31 C Cable, 1 8 Cable s, .
RPC-SERIE S OWNER’S MAP INDEX 81 R Reboot , 14, 20 , 22, 29, 31, 41 Remote Acce ss, 5, 28, 3 7 Remote Operations , 38 Repacka ging, 6 1 Reset, 22, 31, 41, 55, 57, 70 Returning, 61 Ring Detect Reset,.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bay Technical Associates RPC-2 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bay Technical Associates RPC-2 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bay Technical Associates RPC-2 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bay Technical Associates RPC-2 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bay Technical Associates RPC-2, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bay Technical Associates RPC-2.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bay Technical Associates RPC-2. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bay Technical Associates RPC-2 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.