Manuale d’uso / di manutenzione del prodotto TA54 del fabbricante Stanley Black & Decker
Vai alla pagina of 18
© 2012 Stanley Black & Decker , Inc. New Britain, CT 06053 U.S.A. 62288 1/2013 V er . 6 S afety , O pera tiOn and M aintenance USer ManUaL T A54 HYDRAULIC T AMPER.
.
T A54 User Manual ◄ 3 T ABLE OF CONTENTS SERVICING: This manual contains safety , operation, and routine maintenance instructions. Stanley Hydraulic T ools recommends that servicing of hydraulic tools, other than routine maintenance, must be performed by an au - thorized and certied dealer .
4 ► T A54 User Manual SAFETY SYMBOLS Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULA TIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte- nance personnel.
T A54 User Manual ◄ 5 SAFETY PRECAUTIONS T ool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the tool and hose. These safety precautions are given for your safety .
6 ► T A54 User Manual T OOL STICKERS & T AGS SAFETY T AG P/N 15875 (Shown smaller then actual size) DANGER DANGER READ OPERA TION MANUAL AND SAFETY INSTRUCTIONS FOR THIS TOOL BEFORE USING IT . USE ONL Y P ARTS AND REP AIR PROCEDURES APPROVED BY ST ANLEY AND DESCRIBED IN THE OPERA TION MANUAL.
T A54 User Manual ◄ 7 HOSE TYPES The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy- draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic T ools.
8 ► T A54 User Manual HOSE RECOMMENDA TIONS Oil Flow Hose Lengths Inside Diameter USE ( Press/Return) Min. Working Pressure GPM LPM FEET METERS INCH MM PSI BAR Certied Non-Conductive Hose - Fiber.
T A54 User Manual ◄ 9 HTMA / EHTMA REQUIREMENTS Flow Range Nominal Operating Pressure (at the power supply outlet) System relief valve setting (at the power supply outlet) Maximum back pressure (at tool end of the return hose) Measured at a max. uid viscosity of: (at min.
10 ► T A54 User Manual OPERA TION PRE-OPERA TION PROCEDURES PREP ARA TION FOR INITIAL USE The tool, as shipped, has no special unpacking or as- sembly requirements prior to usage. Inspection to as- sure the tool was not damaged in shipping and does not contain packing debris is all that is required.
T A54 User Manual ◄ 1 1 T OOL PROTECTION & CARE • Make sure all couplers are wiped clean before con- nection. • The hydraulic circuit control valve must be in the OFF position when coupling or uncoupling hydrau- lic tools. Failure to do so may result in damage to the quick couplers and cause overheating of the hy- draulic system.
12 ► T A54 User Manual TROUBLESHOOTING SYMPTOM CAUSE SOLUTION T ool does not run. Power unit not functioning. Check power unit for proper ow and pressure (3–9 gpm/1 1–34 lpm at 1000–2000 psi/70–140 bar). Couplers or hoses blocked. Remove restriction.
T A54 User Manual ◄ 13 TROUBLESHOOTING SYMPTOM CAUSE SOLUTION Oil leakage on piston rod. Lower piston seal failure. Replace seal and wiper , piston and nose as required. Oil leakage around trigger . V alve spool seal failure. Replace seals. Oil leakage around spool end caps.
14 ► T A54 User Manual SPECIFICA TIONS Oil Flow Range .............................................................................................................................. 3-9 gpm/1 1-34 lpm Pressure Range ..................................
T A54 User Manual ◄ 15 T A54 P ARTS ILLUSTRA TION.
16 ► T A54 User Manual T A54 P ARTS LIST ITEM QTY P ART NO. DESCRIPTION 1 1 01038 THRUST BRIDGE W ASHER 2 1 00823 CUSHION 3 1 00834 O-RING 4 1 01262 O-RING 5 1 14883 NOSE 6 1 01795 JAM NUT 7 1 14891.
.
Stanley Hydraulic T ools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www .stanleyhydraulic.com IMPORT ANT T o ll out a Product Warranty Recording form, and for information on your warranty , visit Stanleyhydraulic.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Stanley Black & Decker TA54 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Stanley Black & Decker TA54 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Stanley Black & Decker TA54 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Stanley Black & Decker TA54 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Stanley Black & Decker TA54, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Stanley Black & Decker TA54.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Stanley Black & Decker TA54. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Stanley Black & Decker TA54 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.