Manuale d’uso / di manutenzione del prodotto GT18B02 del fabbricante Stanley Black & Decker
Vai alla pagina of 27
© 2012 Stanley Black & Decker , Inc. New Britain, CT 06053 U.S.A. 65465 5/2013 V er . 13 S afety , O pera tiOn and M aintenance USer ManUaL GT18B01 GT18B02 HYDRAULIC POWER UNIT.
2 ► GT18B01-B02 User Manual CERTIFICA TE OF CONFORMITY DECLARA TION OF CONFORMITY DECLARATION OF CONFORMITY ÜBEREINSTIMMUNGS-ERKLARUNG DECLARATION DE CONFORMITE CEE DECLARACION DE CONFORMIDAD DICHI.
GT18B01-B02 User Manual ◄ 3 T ABLE OF CONTENTS WARNING SERIOUS INJUR Y OR DEA TH COULD RESUL T FROM THE IMPROPER REP AIR OR SERVICE OF THIS T OOL. REP AIRS AND / OR SERVICE T O THIS TOOL MUST ONL Y BE DONE BY AN AUTHORIZED AND CERTIFIED DEALER. SERVICING: This manual contains safety , operation, and routine maintenance instructions.
4 ► GT18B01-B02 User Manual SAFETY SYMBOLS Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULA TIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte - nance personnel.
GT18B01-B02 User Manual ◄ 5 SAFETY PRECAUTIONS T ool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the equipment. These safety precautions are given for your safety .
6 ► GT18B01-B02 User Manual T OOL STICKERS & T AGS CHOKE D ANGER PULL TO ST ART PUSH TO RUN 62302 Power Unit Dash Decal 62300 Single Circuit Decal 28322 CE Decal GT18B01 Only 66653 Guaranteed So.
GT18B01-B02 User Manual ◄ 7 HOSE TYPES The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy- draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic T ools.
8 ► GT18B01-B02 User Manual HOSE RECOMMENDA TIONS Oil Flow Hose Lengths Inside Diameter USE ( Press/Return) Min. Working Pressure GPM LPM FEET METERS INCH MM PSI BAR Certied Non-Conductive Hose -.
GT18B01-B02 User Manual ◄ 9 HTMA / EHTMA REQUIREMENTS Flow Range Nominal Operating Pressure (at the power supply outlet) System relief valve setting (at the power supply outlet) Maximum back pressure (at tool end of the return hose) Measured at a max.
10 ► GT18B01-B02 User Manual OPERA TION PREP ARA TION FOR USE Do not operate the power unit until you have read the engine operating and maintenance instructions manual furnished with the unit. 1. ENGINE CRANKCASE OIL LEVEL Always check the oil level before starting the engine.
GT18B01-B02 User Manual ◄ 1 1 OPERA TION QUICK DISCONNECT COUPLERS H.T .M.A. approved quick disconnect couplings are installed to hydraulic hoses so that the direction of oil ow is always from the male to the female quick disconnect as shown in gure 2.
12 ► GT18B01-B02 User Manual OPERA TION CONTROLS This unit is equipped with an advanced proportional engine control system. It provides a means of controlling engine speed by adjusting the fuel control lever with an actuator .
GT18B01-B02 User Manual ◄ 13 OPERA TION COLD WEA THER ST ARTUP 1. Use the procedures described under "ST ARTUP" and then follow the procedure below .
14 ► GT18B01-B02 User Manual ROUTINE MAINTENANCE ENGINE MAINTENANCE Follow the maintenance schedule and general mainte - nance instructions in the engine maintenance and opera - tion manual furnished with the power unit. SP ARK PLUG On power units equipped with Briggs & Stratton Engines, ONL Y Champion RC12YC or equivalent can be used.
GT18B01-B02 User Manual ◄ 15 PROGRAMMABLE CONTROLLER The Stanley programmable controller is an electronic engine governor that provides a means of controlling and limiting engine speed by adjusting the fuel control lever with a proportional actuator .
16 ► GT18B01-B02 User Manual F AUL T CODES 1 APECS unit not calibrated yes Have engine serviced by an Authorized Stanley Dealer . 2 Engine speed excessive yes Have engine serviced by an Authorized Stanley Dealer . 3 Engine speed unusually low yes Have engine serviced by an Authorized Stanley Dealer .
GT18B01-B02 User Manual ◄ 17 TESTING & TROUBLESHOOTING GENERAL T ests and adjustments should be performed periodically to ensure the power unit is operating at maximum efciency .
18 ► GT18B01-B02 User Manual TROUBLESHOOT ONG ENGINE WILL NOT ST AR T . FLOW SELECTOR SWITCH NOT MAKE SURE THE FLOW SELECT OR SWITCH IS IN IN THE OFF POSITION. THE OFF POSITION WHEN ST AR TING. BA TTER Y NOT CONNECTED. A TT ACH BA TTERY CABLES, CHECK WIRES.
GT18B01-B02 User Manual ◄ 19 SPECIFICA TIONS Engine: .................................................................................................................................................... 18 hp Briggs Capacity..........................
20 ► GT18B01-B02 User Manual GT18B01 & B02 P ARTS ILLUSTRA TION.
GT18B01-B02 User Manual ◄ 21 GT18B01 & B02 P ARTS LIST Item No. Part No. Qty Description 1 36150 1 Mufer 1A 65456 1 Spark Arrester 2 36151 1 Heat Shield 3 36152 2 Screw , Hex Washer 4 59007 1.
22 ► GT18B01-B02 User Manual FUEL T ANK & CAP NOTE: When ordering a fuel tank (item 37) or fuel tank cap (item 35) DO NOT MIX OLD STYLE T ANK AND CAP WITH NEW STYLE T ANK AND CAP .
GT18B01-B02 User Manual ◄ 23 Item No. Part No. Qty Description 1 370502 7 Capscrew , 5/16 in.-18 UNC 2 03906 7 Nylock Nut, 5/16 in. -18 UNC 3 62267 1 Handle, Rear Lift 4 58857 1 Coupler , Male 3/8 in., -8 SAE 5 58856 1 Coupler , Female 3/8 in., -8 SAE 6 60962 2 Capscrew , 1/4 in.
24 ► GT18B01-B02 User Manual 9 8 7 1 2 3 5 6 3 4 11 3 10 3 12 Item No. Part No. Qty Description 1 59130 1 Manifold Assy , Single Circuit 2 59104 1 Hose Barb, 3/4 in.
GT18B01-B02 User Manual ◄ 25 MAIN WIRING HARNESS RECTIFIER WIRE WHITE CONTROLLER TO MAGNETO WIRE ON ENGINE GRA Y WIRE OIL PRESSURE SWITCH FUEL SHUTOFF RED WIRE - THROTTLE CONTROL SWITCH (NOTE: PLUG .
.
Stanley Hydraulic T ools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www .stanleyhydraulic.com IMPORT ANT T o ll out a Product Warranty Recording form, and for information on your warranty , visit Stanleyhydraulic.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Stanley Black & Decker GT18B02 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Stanley Black & Decker GT18B02 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Stanley Black & Decker GT18B02 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Stanley Black & Decker GT18B02 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Stanley Black & Decker GT18B02, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Stanley Black & Decker GT18B02.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Stanley Black & Decker GT18B02. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Stanley Black & Decker GT18B02 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.