Manuale d’uso / di manutenzione del prodotto 9631 del fabbricante Sound Performance Lab
Vai alla pagina of 17
Manual Digital Harmonics Processor Spectralizer Model 9631.
SOUND PERFORMANCE LAB by Her mann Gier and P aul W hite V ersion 2.2 – 1 / 1999 T he inf or mation in this document has been caref ull y verif ied and is assumed t o be correct. How ever Sound P erf or mance Laborat ory (SPL) reserv es the right t o modify the product described in t his manual at any time .
3 Spectralizer Contents Dear cust omer , T hank you f or the c onf idence you ha ve shown t owards SPL electronics GmbH by purc hasing t he SPL S PECTRALIZER . Y ou hav e decided to use a t ool of high perf or mance w hic h sets you in the position to ha ve f ast er success and a better sound quality in your music productions and pre-mast erings .
4 Spectralizer SPL digital audio processors are designed in c ooperation wit h Spectral Design of Bremen, Ger many , w ho are responsible f or t he DSP programming .
5 Spectralizer Operation Safety t he small timing glitc hes t hat w ould otherwise occur w hen switc hing the process in and out. Up t o 99 presets can be stored and c hanged using a MIDI program c hange command.
6 Spectralizer Connections Bef ore connecting t he S PECTRALIZER switc h the pow er of f at all c onnected units . T he rear panel provides AES/EBU- and S/P-DIF-inputs and outputs . Any additional c hannel, status and user -bits are passed t hrough unaltered, and t he outputs can be used at t he same time if required.
7 Spectralizer Flow Chart Quick-Start Generator 2nd Harmonic Encoder Density- Encoder Generator 3rd Harmonic Encoder Effect Original Solo- T aste Kick- Encoder Frequency- Encoder Highpass - Filter Mix.
8 Spectralizer 3 2 7 6 5 4 12 Rela y hard-bypass f or AES/EBU input and output I NPUT G AIN = 0 for pr ocessing pre-pr oduction material with enough headroom Choose neg ative I NPUT G AIN values f or .
9 Spectralizer F REQUENCY sets t he starting frequenc y of t he highpass f ilter . Abov e this frequenc y sec ond and third har monics are being generated. T he highpass f ilter can be v aried between 1 kHz and 7 kHz in steps of 500 Hz. M IX c ontrols t he mix level betw een t he processed and the unprocessed signal.
10 Spectralizer Diagram 3: 3 RD H ARMONIC T he illustration shows t he F FT spectr ums of the odd harmonics f or a measuring signal of 3 kHz. Diagram 4: If two fr equencies are f ed into the Spectrali.
11 Spectralizer Control Elements D ENSITY increases t he l oudness of t he generated har monics by appl ying diff erent “c ompression ratios”. T he control of f ers six positions . Adjus tment: If D ENSITY is set t o 0, the generat ed harmonics hav e low intensity ev en at high values f or 2 ND and 3 RD H ARMONIC .
12 Spectralizer Control Elements If you w ant to appl y various presets depress A PPL Y f or one sec ond. T he A PPL Y LED st arts to f lash indicating t hat the A PPL Y mode is activat ed. Y ou can step t hrough t he preset list wit h U P and D OWN .
13 Spectralizer Control Elements or : AES/EBU input wit hout w ordc loc k is detected Press A PPL Y : S/P-DIF input detect ed or : no S/P-DIF input detect ed Press A PPL Y (if S/P-DIF is detected): S/P-DIF wit h w ordc loc k detected or : S/P-DIF input wit hout w ordc loc k is detected 3.
14 Spectralizer 6. Dis pla ying t he Channel Dif f erence Error flag: N O = no error detect ed; Y ES = error detect ed 7. Setting or erasing t he Cop y-Prohibit flag: N O = f lag erased or not set; Y ES = flag set 8. Dis pla ying t he Original f lag: N O = no Original f lag; Y ES = Original 9.
15 Spectralizer 13 Output PPM MIDI IMPLEMENT A TIONS Function Received Data Note Basic Channel: Change 1-16 stored Control Change: 7 1-127 V olume Program Change: 0-99 real value In order to increase operation saf ety only send t he necessary MIDI data t o t he S PECTRALIZER .
16 Spectralizer Specifications Input/Output Sample rate frequency , autom. 32-48kHz AES/EBU , twisted pair ( 1 ) AES 3 AES/EBU in- & output impedance 110 Ohms S/P -DIF , co-axial ( 2 ) SPDIF -2 S/.
17 Spectralizer SPL electronics GmbH (hereafter called SPL) products are w arranted onl y in the c ountry w here purc hased, through t he authoriz ed SPL distributor in t hat c ountry , against def ects in material or w orkmanship .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sound Performance Lab 9631 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sound Performance Lab 9631 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sound Performance Lab 9631 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sound Performance Lab 9631 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sound Performance Lab 9631, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sound Performance Lab 9631.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sound Performance Lab 9631. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sound Performance Lab 9631 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.