AFE325 Product Manual Purpose of this manual: To provide detailed installation and operation instructions; to give insights into how the machine works; to list possible causes for problems; and to suggest procedures for specific types of service. The AFE325 is an ice maker that makes and stores flaked ice.
Specifications: . Model Dimensions Basic Electrical Condenser Type Min. Circ. Ampacity Max. Fuse Size Refrigerant Charge (R-134a) AFE325AE-1A 33 x 36 1 ⁄ 16 x 24 115/60/1 Air Cooled 10.7 15 11 oz. AFE325AE-6A 33 x 36 1 ⁄ 16 x 24 230/50/1 Air Cooled 5.
To The Installer: A professional installation of any product is critical to the long term satisfaction of the user. The AFE325 is designed to be installed indoors, near a drain. Determine the location from the anticipated use and any options planned for.
For The Plumber Drains: The ice maker requires a gravity drain for the reservoir overflow and bin drain. T he pit c h on the drain tubes must be at least 1/ 4 inch f all per foot of horizontal run. On long horizont al runs, a vent at the back of t he cabinet will improve draining, and is recommended.
For The Electrician Electrical connections: Follow All Local, State & National Codes Check the nameplate for voltage and current requirements. An electrical cord is not supplied. Connect the AFE325 to a separate electrical circuit. Wiring to the machine must conform to all codes.
Final Check List & Initial Start Up 1. Is the machine located indoors where the temperature limitations are not exceeded? 2. Is there at least 6" clearance on the left side and the back of the cabinet for adequate air flow? 3. Is the water supply adequate, and has a shut off valve been installed? 4.
User Operation The AFE325 is an automatic ice flaked machine. All it requires is cool air, clean water, a drain, and an adequate supply of electrical power. The user must regularly sanitize and clean the machine. Component Location & Function Evaporator.
Component Location: Control Box Auger Delay Pressure Control: This pressure switch, connected to the low side of the refrigeration system, controls the auger drive motor. On-Off switch: This toggle switch shuts off the machine. It is not a complete disconnect.
Refrigeration System Operation The AFE325 uses a forced draft air cooled condenser, capillary tube and hermetic compressor. The system uses R-134a as a refrigerant. High pressure, high temperature refrigerant is forced thru the condenser where it looses enough heat to condense.
Water System Operation: The water system consists of a float valve and reservoir. The water level in the reservoir tank is the same level as that inside the evaporator. Building water supply flows to the float valve and the float valve opens to add water to the reservoir as water flows out to the evaporator.
Mechanical Operation ELECTRICAL SEQUENCE There are two circuits in the AFE325: one is a series circuit with several switches connected in series to the compressor. The other is a parallel branch of the series circuit, controlling the gear drive motor.
Sanitation and Cleaning Mai ntenance : The water and ice makin g syste ms will n eed t o b e period ica lly sanitize d and de-min era lized . Th e air coole d con dens er will also ne ed to be kept clea n. Det aile d ins tru ctio ns are pro vide d on pag e 14.
Maintenance and Cleaning In some areas, the water supply to the ice maker will contain a high concentration of minerals, and that will result in an evaporator and auger becoming coated with these minerals, requiring a more frequent removal than twice per year.
Maintenance: Air Cooled Condenser, Bearings 1. Disconnect electrical power. 2. Remove front louvered panel 3. Wipe the lint off the front of the condenser. If needed, clean the interior of the condenser. 4. Use pressurized air to blow the lint from the inside of the condenser.
Maintenance: Component Inspection Auger. The auger is made of stainless steel. It has a polished surface that may be very shinny or dull. Allow the auger to dry, if mineral scale is found on the auger’s surface, clean off the auger with ice machine cleaner and a scrubbing pad.
Service Diagnosis Problem Possible Cause Probable Correction No ice, nothing is operating. Unit has no power. Restore power. If breaker or fuse tripped, check for overloaded circuit or short circuit. Master switch off Switch unit on. Determine why switch was off.
Service Diagnosis PROBLEM POSSIBLE CAUSE PROBABLE CORRECTION Unusual noise Mineral scale in evaporator Clean water system with ice machine cleaner. Auger coupling dry Grease coupling Auger coupling worn Replace coupling and adapter stand. Bearings worn Replace bearings and water seal.
Removal and Replacement Water System The water system consists of the reservoir and inlet water valve. Reservoir. 1. Shut off the water supply. 2. Remove the top panel. 3. Remove the left side panel. 4. Drain the water reservoir and evaporator. 5. Disconnect inlet and outlet tubes from the reservoir.
Water Seal & Bottom Bearing Replacement: 1. Remove old rotating half from the auger. Clean the mounting area. 2. Place a bead of food grade sealant (such as Scotsman part number 19-0529-01) onto the shoulder of the auger where the rotating half of the water seal will be installed.
Refrigeration System This ice machine uses R-134a as the refrigerant. This refrigerant has no chlorine, and therefore requires polyolester type refrigerant oil. This oil requires specific service procedures. Service Recommendations: This ice machine has a sealed refrigeration system.
Gear Reducer Removal 1. Disconnect electrical power. 2. Shut off the water supply. 3. Remove the top, front and side panel. 4. Remove the control box cover. 5. Remove the centrifugal switch cover on the top of the auger drive motor. 6. Disconnect the electrical wires from the centrifugal switch.
Gear Reducer Rebuild 1. After the gear reducer has been removed, the internal components may be inspected and/or replaced. Remove all bolts holding the two case halves together. 2. T ap against the roll pins at each end of the gear cases to split them.
Motor Cover & Top Rotor Bearing Fan Stator Rotor First Gear Shaft Seals, 2 are used per shaft as shown Woodruff Key Spacer Washer, Use To Adjust Height of Gears to Avoid Rubbing Gear Reducer AFE32.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Scotsman Ice AFE325 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Scotsman Ice AFE325 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Scotsman Ice AFE325 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Scotsman Ice AFE325 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Scotsman Ice AFE325, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Scotsman Ice AFE325.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Scotsman Ice AFE325. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Scotsman Ice AFE325 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.