2003.12.19 H8/36014 Group, H8/36024 Group FP-48B User System Interface Cable for E6000 Emulator User’s Manual HS36014ECH64H Renesas Micro computer Development Environmen t System Rev.
Cautions Keep safety first in your circ uit desi gns! 1. Renesas Technology Corp . puts the maximum e ffort int o making s emiconducto r product s better and more reliable, but the re is always the poss ibility that trouble may occ ur with them. Trouble with semi conductors may lead t o personal i njury, fire or propert y damage.
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this u ser system interface cable. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user sy stem interface cable until y ou fully understa nd its mec ha ni s m.
II LIMITED WARRANTY Renesas warrants its user system interface cabl es to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will re pair or replace any user system interfac e cables dete rmined to be defective in material and/or workmanship.
III State Law: Some states do not allo w the exclusion or limitatio n of implied warranties or liabilit y for incidental o r consequential d amages, so t he ab o ve limitation or excl usion ma y not appl y to you. This warr ant y give s yo u spec if ic lega l rig hts, and you ma y have other rig hts wh ic h may va ry fro m state to state.
IV SAFETY PAGE READ FIRST • READ this user's manual before using this u ser system interface cable. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user sy stem interface cable until y ou fully understa nd its mec ha ni s m.
V W ARNING Observe the pr ecautions listed below. Failur e to do so will result in a FIRE HA ZARD and will damage the user system and the emula tor product or will result in PERSONAL INJURY. Th e USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product b y yourself for e lectric sho ck prevention and quality assurance.
i Preface Thank y ou for purchasi ng th is user s ys tem in terface cable (HS36014ECH64H) for the R enesas’s origin al microcom puter H8/36014series.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connectin g User Sys tem Interface C able to Emu lator Station (H8/36014 Series) .
1 Section 1 Configuration CAUTION Use an NQPACK048SD socket (manufactured by Tokyo Eletech Corporation ) for the FP- 48B package IC socket on the user system. Figu re 1 show s the config uration of the HS36014EC H64H user sy stem in terface cable for the FP-48B package.
2 Table 1 lists t he HS36014ECH64H com ponents . Please mak e sure y ou have all of th ese compon ents when u npacking. Table 1 HS36014ECH64H Com ponents No.
3 Section 2 Connection Procedures 2.1 Connectin g User System Interface Cable to Emulator S tation (H8/36014 Series) W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
4 Figure 2 Connecting User System Interface Cable to Em ulator Station.
5 2.2 Connectin g User System Interface Cable to Ex pansion I/O Board (H8/36024 Series) W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from an y part. Before connecting, make sure that pin 1 on bot h sides are correctly aligned.
6 Cable body connector User system interface cable CTS screws (M3 x 6 mm) Expansion I/O board cable USER INTERFACE CABL E6000 EMULATO E6000 Figure 3 Connecting User System Interface Cable to Expansion.
7 2.3 Connectin g User System Interface Cable to User S ystem W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned.
8 2.3.3 I nserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-48B packag e on the user sy stem w ith pin 1 on the u ser system interface cable head, and in sert the user system interface cable head into th e IC socket on the user sy stem, as show n in figure 4.
9 Fasten the us er system interf ace cable head to the IC socket for a FP-48B packag e on the user system with the four screws (M2 x 10 mm ) provided. Each screw should be tightened a little at a tim e, alternating betw een screw s on opposing corners.
10 2.3.5 Fastening Cable B ody Connect the cable body to the cable head. Figure 5 Fastening Cable Body.
11 2.4 Recomm ended Dimensions for User System Mount Pad Figure 6 show s the recomm ended dimens ions for the mou nt pad (footprin t) for the user system w ith an IC socket for an FP-48B pack age (NQPACK048SD: m anufactu red by Toky o Eletech Corporation).
12 2.5 Dimensions f or User System Interface Cable H ead The dimens ions for the user sy stem interface cable h ead are shown in f igure 7. ± Figure 7 Dim ensions for User System Interface Cable Head.
13 2.6 Resulting Di mensions after Conn ecting User System Interface Cab le The resulting dim ensions, after connectin g the user system interface cable head to the u ser system , are show n in figure 8.
14 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use the screwdriver provided fo r tightening screws.
15 Figure 9 Installing M CU to User System.
16 Section 4 Verifying Operation 1. When u sing the H8/ 36014 series E6000 em ulator (HS3664EPI61H), tu rn on the em ulator according to th e procedures described in the H8/300H Series E6000 Emu lator User's Manual (HS300HEPI61HE).
17 Figure 10 shows the sy stem clock oscillator on the user sy stem interface cable. Figure 10 System Clock Oscillator.
18 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned w ith pin 1 on the cable head before insertin g the cable head into the us er system IC sock et. 2. The dimens ions of th e recommen ded moun t pad for the user sy stem IC socket are diff erent from those of th e MCU.
19 Figure 12 P1 Short Connector.
H8/36014 Group, H8/36024 Group FP-48B User System Interface Cable for E6000 Emulator User's Manual Publication Date: Rev.1.00, July 25, 2002 Rev.2.00, December 19, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co.
H8/3601 4 Grou p, H8/3 6024 Group FP -48B User Sy stem I nterface Cable for E 6000 Emulato r User’ s Manual REJ10B0093-0200H.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Renesas H8/36014 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Renesas H8/36014 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Renesas H8/36014 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Renesas H8/36014 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Renesas H8/36014, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Renesas H8/36014.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Renesas H8/36014. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Renesas H8/36014 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.