10623 Roselle Street, San Dieg o, CA 92 121 • (858) 550-9559 • FAX (858) 550-7322 contactus@ accesio.com • www.accesi o.com MODELS PCI-IDI-XX SERIES USER MANUAL File: mpci-idi-48.
Notice The information in this document is provided for reference only. ACCES does n ot assume any liability arising out of the application or use of the informat ion or products d escrib ed herein.
Warranty Prior to shipment, ACCES equipment is thoroughly insp ecte d and tested to applicable sp ecifi cations. However, should equipment failure occu r, ACCES assu res its custo mers that pr ompt service and su ppo rt will be available.
Table of Contents Chapter 1: Introduction ................................................................................................. 5 Table 1-1 : Model Versions ..................................................................................
Chapter 1: Introduction Features • Individually-Isolated AC/DC Inputs for up to Three 16-Bit Group s, 48 total. • Reverse Polarity protection • AC Filtering • Optical Isolation, Channel-to- Channel and Channel -to-Host PC. • Change-of-State detection (ce rtain mo dels).
MODEL No. of Bits Max Input Voltage Change-of State Interrupt Capability AC Filter 16A 16 31V No Yes 16AC 16 31V Yes Yes 32A 32 31V No Yes 32AC 32 31V Yes Yes 48A 48 31V No Yes 48AC 48 31V Yes Yes 16B.
Specification Digital Isolated Inputs Number of inputs: 16, 32, or 48 Type: Non-polarized, optically isolated from each other and from the com puter (CMOS c ompatib le) Voltage Range xxA: Logic Low: 0 to 1.
ADDRESS AND CONTROL LOGIC COMPUTER PCI BUS CHANGE-OF- ST A TE DETECT IS O L ATE D IN P U T 0 IS O L ATE D IN P U T 4 7 PCI BUS INTERF ACE I NPU TS 0-47 Vcc CURRENT LI M I TE R Vcc CURRENT LI M I TE R .
Chapter 2: Installation A printed Quick-Start Guide (QSG) is pa cked with the card for your convenience. If you’ve already performed the steps from the QSG, you may find this chapter to be redu ndant and may skip forward to begin developing your application.
Hardware Installation 1. Do not install card into the computer until the software has been fully installed. 2. Turn OFF computer power AND unplug AC power fro m the system. 3. Remove the computer cover. 4. Carefully install the card in an available 5V or 3.
Chapter 3: Option Selection Each channel has a jumper configurabl e filter option. 3.90 " 6.9 0" NO F IL T ER FIL TER FL T 0 FLT1 5 FLT1 6 FLT3 1 FLT3 2 FLT4 7 Figure 3-1: Option Selection Map Filter Response Switch Jumpers are use d to select input filtering on a channel-by-channel basis (see Figure 3 -1).
Chapter 4: Address Selection This card uses I/O addre sses offset from the base a ddress assigned by the PC I bus. T he address spaces are defined in the Programming se ction of this manual.
Chapter 5: Programming The base address is assigned by the computer system duri ng installation and will fall on an eight byt e boundary. The card’s read and write fun ctions are a s follows: Addres.
Write Base + 7: COS En able/Disable Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 IRQ Enable/ Disable N/A N/A N/A N/A N/A N/A N/A Manual PCI-IDI-XX Series 14.
Chapter 6: Connector Pin Assignments Isolated inputs are connected to the card via a 50-pin HEAD ER type connector. There are three connectors named PORT0, PORT 1, and PORT2. The table below describes PORT 0. PORT1 and PORT2 are identical pinouts. Pin 50 is located towa rd the Jumpers, while Pi n 1 is located near connection to Motherboard.
Customer Comments If you experience any problems with this manual or ju st want to give us some feedba ck, ple ase email us at: manuals@accesio.com. Please detail any errors you find and in clude your mailing address so that we can send you any manual updates.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Access PCI-IDI-XX è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Access PCI-IDI-XX - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Access PCI-IDI-XX imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Access PCI-IDI-XX ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Access PCI-IDI-XX, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Access PCI-IDI-XX.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Access PCI-IDI-XX. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Access PCI-IDI-XX insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.