H8/3257 Series, H8/325 Series FP-64A User System Interface Cable (HS3257ECH61H) for E6000 Emulator User’s Manual ADE-xxx-xxx Rev. 3.0 4/1/03 Renesas Technology Corp.
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing the E6000 em ulator for the Renesas’s original m icroprocessor H8/300 series. The HS3257ECH61H is a user system interface cable that connects an H8/300 series E600.
ii Contents Section 1 Configuration ..................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration CAUTION Use an IC149-064-008-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64A package IC socket on the user system. Figure 1 shows the configuration of the HS3257E CH61H user system interface cable for the FP-64A package IC socket Cable head User system Socket cover Screws (M2.
2 Table 1 lists the HS3257ECH61H com ponents. Please m ake sure you have all of these components when unpacking. Table 1 HS3257ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes cables 2 Cable head 1 3 IC socket 1 For the FP-64A package 4 Socket cover 1 For installing an FP-64A-packaged MCU 5 Screws (M2.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY.
Figure 2 Connecting User System Int erface Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
5 2.2.2 Soldering IC Socket After fastening, solder the IC socket for an FP-64A package to the user system. Be sure to completely solder the leads so that the solder slo p s gently over the leads and fo rms solder fillets. (Use slightly more solder than the MCU.
Screws (M2.0 x 12 mm) and flat washers Cable head Pin 1 IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 3 Connecting User System Interface Cable to User .
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Cable head Unfastening jig Push the unfastening jig Removing User system Figure 4 Fastening Cable Body 7.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recomm ended dime nsions for the mount pad (foot print) for the user system with an IC socket for an FP-64A package (IC149-064-008-B5: manufactured by YAM AICHI ELECTRONICS Co., Ltd.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 9.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7. 9.4 Unit: mm Tolerance: ± 0.5 mm User system IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co.
11 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head.
MCU Pin 1 mark User system Socket cover IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) Figure 8 Installing MCU to User System 12.
Section 4 Verifying Operation 1. When using the H8/300 series E6000 emulat or (HS3008EPI60H), turn on the emulat or according to the procedures described in th e H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE).
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MC U.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Renesas H8/325 Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Renesas H8/325 Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Renesas H8/325 Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Renesas H8/325 Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Renesas H8/325 Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Renesas H8/325 Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Renesas H8/325 Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Renesas H8/325 Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.