Phone (406) 582-0227 · Fax (406) 582-0237 · Quantum Composers, Inc · Bozeman, MT 59772 · PO Box 4248
Page 5 of the Quantum Power Wheelchair (9700) user manual — Parts List
Pagina 5 · clicca per ingrandire
Pagina 5

The following parts are included with the 9700 -- contact Quantum Composers if any

In addition to a 30-day money back guarantee, the Model 9700 has a one-year limited

100µs to 100ms. We also offer a long pulse version which holds up to 10A for 10µs - 500ms. Rather than the usual array of knobs and switches, the 9700 uses a

Since the Model 9700 employs a flexible microprocessor-controlled architecture, the

For questions or comments about operating the 9700, contact Quantum Composers

This manual is designed to help you quickly and easily learn to use your Quantum

warranty from the date of delivery. This warranty covers defects in materials and

controlled current pulses with currents from 0 - 25 Amps and pulsewidths from

Composers Model 9700 current pulse generator. The 9700 provides digitally

menu-driven user interface with "on-line" help -- once you learn the basics of

workmanship. Quantum Composers will repair or replace any defective unit.

9700 can be customized to fit your exact requirements -- contact Quantum Composers for details.

operating your 9700, you may never need to refer to this manual again.

P Internet - www.quantumcomposers.com

1 INTRODUCTION

via one of the following methods:

Technical Support

P Phone - (406) 582-0227

P Fax - (406) 582-0237

P 9700 Pulse Generator

parts are missing:

P AC Power Cord

Parts List

Warranty

P User's Manual

Page 6 of the Quantum Power Wheelchair (9700) user manual — Safety Issues
Pagina 6 · clicca per ingrandire
Pagina 6

can more easily produce a lethal current. Your normal work habits should include all

hardware modifications by merely modifying the software contained inside the 9700

electrical shock because testing must be performed where exposed voltage is present.

certain conditions. Higher voltages pose an even greater threat because such voltage

accepted practices that will prevent contact with exposed high voltage, and those that

An electrical shock causing 10 milliamps of current to pass through the heart will

voltage. You will significantly reduce the risk factor if you know and observe the

Normal use of test equipment exposes users to a certain amount of danger from

stop most human heartbeats. Voltage as low as 35 VDC or RMS AC should be

considered dangerous and hazardous since it can produce a lethal current under

will steer current away from your heart in case of accidental contact with a high

The 9700 is microprocessor-controlled and employs a flexible and expandable

user-interface. New features and operating modes often can be added without

to avoid contacting a nearby metal object that could provide a

5. When testing AC powered equipment, remember that AC line voltage is usually present on some power input circuits, such
1. Do not expose high voltage components needlessly. Remove housings and covers only when necessary. Turn off

remember that high voltage may appear at unexpected points

3. Use an insulated floor material or a large, insulated floor mat to stand on, and an insulated work surface on which to place

equipment. Make certain such surfaces are not damp or wet.

4. Use the time-proven "one hand in the pocket" technique while handling an instrument probe. Be particularly careful

circuits. Discharge high-voltage capacitors after removing

equipment while making test connections in high-voltage

2. If possible, familiarize yourself with the equipment being tested and the location of high voltage points. However,

- contact Quantum Composers for details.

good ground return path.

Custom Modifications

in defective equipment.

following safety precautions:

Safety Issues

power.

Page 7 of the Quantum Power Wheelchair (9700) user manual — Custom Modifications
Pagina 7 · clicca per ingrandire
Pagina 7

as the on-off switch, fuses, power transformer etc., any time

6. Never work alone. Someone should always be nearby to render aid if necessary. Training in CPR first aid is highly

the equipment is connected to an AC outlet, even if the

equipment is turned off.

recommended.

Page 8 of the Quantum Power Wheelchair (9700) user manual — Custom Modifications
Pagina 8 · clicca per ingrandire
Pagina 8
Page 8 of the Quantum Power Wheelchair (9700) user manual — Custom Modifications
Page 9 of the Quantum Power Wheelchair (9700) user manual — Menu Button
Pagina 9 · clicca per ingrandire
Pagina 9

and settings. The left half of the display shows the current menu selection, while the

The 9700 features a backlit liquid crystal display, which displays menu selections

This chapter explains the function of each control and connector on the 9700.

The front panel contains the most frequently used controls and connectors.

right half shows the current setting of the item associated with that menu.

Increments a number or increments the selection for the current item.

Decrements a number or increments the selection for the current item.

2 CONTROLS AND CONNECTORS

Toggles between the various items in a menu.

Toggles between the various sets of menus.

Menu Button

Down Button

Item Button

Up Button

Control Buttons

Front Panel

Display

Page 10 of the Quantum Power Wheelchair (9700) user manual — Output Sections
Pagina 10 · clicca per ingrandire
Pagina 10

for numeric items, pressing and holding this button down displays a brief description

selected for editing. For other items, or when the right most digit is already selected

for numeric items, press and hold this button down to display the range and units for

Each output section is independently controlled and isolated from each other. Loads

selected for editing. For other items, or when the left most digit is already selected

There are two (2) output sections on the front of the 9700; each consists of a pair of

banana plugs, a BNC current monitor, a toggle switch, and a charge level indicator.

are connected to the banana plugs. The toggle switch allows the user to physically

before connecting loads, disconnect bank voltage by placing toggle switch in off

disconnect the output (off position). Disconnecting the outputs is recommended

For numeric items, this button is used to select which digit in a numeric entry is

For numeric items, this button is used to select which digit in a numeric entry is

Disables output of pulses on all channels.

Right Button

Enables output of pulses.

Left Button

Stop Button

Run Button

while connecting loads.

Output Sections

of the current item.

the current item.

position.

Page 11 of the Quantum Power Wheelchair (9700) user manual — Interlock
Pagina 11 · clicca per ingrandire
Pagina 11

A switch is provided to arm/disarm the system. This switch is used with the interlock

The charge level indicator illuminates when the capacitor bank is fully charged. The

Optoisolated input, 3-15V (>3mA). Pressing the RUN button in the external trigger

indicator is provided to indicate that the rear interlock is satisfied and the arm/disarm

This is a 9-pin D-sub connector for the RS232 interface that comes standard with the

This is a BNC connector which provides a TTL sync output when the instrument is

When the system is disarmed, a relay disconnects the bank voltage from the output

9700. It is pinned to be directly connected to a standard IBM-PC serial port -- use a straight-through cable (not a null modem cable) to connect to a PC.

fired. This signal is generated by the internal clock and therefore the actual pulse

switch is in the armed position. No pulses will be generated unless the LED is on.

output will be delayed relative to the Sync Out as specified by the channel delay

instrument to generate pulses. The input must be shorted to satisfy the interlock.

current monitor is an oscilloscope compatible reference voltage to monitor the

input on the rear panel to control pulse generation of the system. A READY

This is a BNC connector which must be appropriately connected to allow the

Trig In (BNC) -- external signal input to trigger the generation of pulses.

mode arms the system and waits for an external trigger input.

current pulse, 1A = 100mV.

External Trigger

Rear Panel

Serial Port

Sync Out

parameter.

Interlock

Interlock

jacks.

Page 12 of the Quantum Power Wheelchair (9700) user manual — GPIB Port (optional)
Pagina 12 · clicca per ingrandire
Pagina 12

A standard EIC instrument-type cord should be used. The 9700 is supplied with a

The GPIB (IEEE 488) interface is available as an option with the 9700.

power cord that fits the type of socket used in your country.

Input requirements100-240VAC, 1A

GPIB Port (optional)

AC Input

Page 13 of the Quantum Power Wheelchair (9700) user manual — Overview
Pagina 13 · clicca per ingrandire
Pagina 13

amount of energy stored on the capacitor bank (CV2/2 = 36.2 Joules). Long pulses or

discharges. The table below shows the maximum droop free pulsewidth as a function

behavior depending on what state the menus are in -- once understood, the menus can

provided by a 3700mF capacitor bank charged to approximately 44V. The ability of

should be taken when making connections. A switch is provided for each channel to

current pulse generator. Some keys are only active at certain times or have different

be quickly and easily manipulated. The 9700 also contains non-volatile memory for

storing up to twelve (12) configurations, so you need not go through the entire setup

the instrument to maintain the requested current will be load dependent, limited by

The 9700 provides digitally controlled, single shot, current pulses. The current is

The 9700 uses a single-line LCD to display menu selections. The front panel keys

are used to “navigate” through sets of menus to set various options and control the

the voltage and the stored energy. Thus the output pulse is energy limited by the

The current in the Model 9700 is controlled by a high-side power mosfet. Care

large loads will result in droop at the end of the pulse as the capacitor bank

10 5 2 1 RESISTANCE (ohms)

75 190 525 1,090 1

50 160 500 1,060 2

-- 90 425 990 5

-- -- 300 860 10

This chapter presents detailed instructions on the operation of the 9700.

MAXIMUM CONSTANT CURRENT PULSEWIDTH (ms)*

CURRENT (A)

3 OPERATING INSTRUCTIONS

disconnect the load from the capacitor bank.

process each time the instrument is used.

of resistance and current.

Overview

Page 14 of the Quantum Power Wheelchair (9700) user manual — Item Edit Mode
Pagina 14 · clicca per ingrandire
Pagina 14

between sets of menus, while the key will toggle between menu items within the

When the current item is numeric, the system enters the Numeric Input mode. In this

pressing and holding the Left arrow key will display a brief description of the current

select among different options for the entry. The Left and Right arrow keys are used

The Main Menu consists of a set of menus selections used to set the operating mode,

In the External Trigger mode, one pulse is output each time an active edge occurs on

current menu item. Pressing and holding the Right arrow key will display the valid

mode, the Left and Right arrow keys are used to select a digit to edit. The selected

item. When the right most digit is active, pressing and holding the Right arrow key

The menu items in the 9700 are arranged in a set. Pressing the key will toggle

digit blinks to identify itself as the active digit. The Up and Down arrow keys are

then used to increment or decrement this digit. When the left most digit is active,

the Trigger input. The external trigger polarity menu (TRIG) is used to determine

When the current item is non-numeric, the Up and Down arrow keys are used to

whether the 9700 is triggered on the rising or falling edge of the external trigger.

current set. Hold down the Left arrow key to receive a short description of the

will display the range and units for the current item.

There are two (2) different Pulse modes available.

time period and frequency of the 9700.

to display a description of the item.

MODE - Pulse Modes

External Trigger Mode

Selecting Menu Items

Numeric Input Mode

range for that item.

Item Edit Mode

Main Menu

Page 15 of the Quantum Power Wheelchair (9700) user manual — n :Dly - T n :Delay
Pagina 15 · clicca per ingrandire
Pagina 15

This set of menus is used to set enable and set the current, delay, pulse width for each

n:Iamps menu where n = 1, 2. Currents from 00.00 to 25.00A may be selected with a

charged to nominally 44V. The maximum current available will therefore be limited

seconds to charge.) The charge ready LED indicator illuminates when the capacitor

Tn:Dly menu, where n = 1, 2. Delays from 0 to 99.999999 seconds may be selected

When in External Trigger mode, the delays are with respect to the active edge of the

pressed. The rate at which pulses are produced is totally dependent on how fast the

Each of the two (2) channels has independent output control and may be enabled or

disabled from the nEnable menu, where n = 1, 2. When disabled, the channel will

resolution of 10mA. Current is provided from a 3,700mF capacitor bank, which is

Each of the two (2) channels has an independent delay setting which is set from the

Run key is pressed. The delay of each of the outputs is relative to To (the internal

When in any mode but External Trigger, the Delay setting sets the delay from the

time the internal timer To goes high until a pulse is output on a particular channel.

to the bank voltage and the load resistance. (The capacitor bank is charged by an

Each of the two (2) channels has an independent output current setting from the

isolated power supply which is current limited and thus takes approximately 15

During Single Shot operation, one pulse is generated each time the Run key is

not generate a current pulse when the unit is triggered.

n: Enable - T n: Enable

external trigger input signal.

with a resolution of 200ns.

n :Iamps - T n :Iamps

Channel Menus

Single Shot Mode

of the output channels.

n :Dly - T n :Delay

bank is fully charged.

clock).

Page 16 of the Quantum Power Wheelchair (9700) user manual — n :Wid - T n :Pulse Width
Pagina 16 · clicca per ingrandire
Pagina 16

Each of the two (2) channels has an independent pulse width setting which is set from

The pulse width is used to specify the duration of the output pulse. The setting of the

A configuration is stored by using the Up and Down arrow keys to select the memory

press the key to verify that you want to overwrite the active configuration. If you

location number and pressing the Left or Right arrow key. You will be prompted to

output polarity (the Tn:Pol menu) for a particular channel determines whether the

configurations. The settings for all menu selections are stored and can be quickly

Stores the current menu settings in the specified memory location one (1) - twelve

Recalls a previously stored configuration from the specified memory location. To

selected with a resolution of 200ns. *See custom features for Long Pulse option

location number and press the Left or Right arrow key. You will be prompted to

configuration. If you press any other key, the configuration will not be saved.

the Tn:Wid menu, where n = 1, 2. Pulsewidths from 100µs to 100ms may be

recall a configuration, use the Up and Down arrow keys to select the memory

The 9700 contains non-volatile memory for storing twelve (12) different

press the key to verify that you want to overwrite the existing stored

press any other key, the configuration will not be recalled.

Store/Recall/Misc. Menus

instrument to the factory default settings.

output is high for this duration or low.

n :Wid - T n :Pulse Width

RECALL Configuration

STORE Configuration

specifications.

recalled.

(12).

Page 17 of the Quantum Power Wheelchair (9700) user manual — Volume
Pagina 17 · clicca per ingrandire
Pagina 17

4,294,967,295 after which the count rolls over to zero. To manually reset the counter to zero, press the Left or Right arrow key. You will prompted to press the key

The key click volume may be adjusted from 0 (disabled) to 9. The default value is 2.

For systems with the optional GPIB interface this menu sets the GPIB address. The

(comma). The period is generally used in North America, while the comma is used

The 9700 includes a nine (9) digit shot counter. The maximum count displayed is

to verify that you want to zero the counter. If you press any other key, the shot

The character used as a decimal point can be set to either a "." (period) or a ","

valid address range is from 0 to 30.

GPIB:Addr (optional)

counter will not be reset.

Shot Counter

in Europe.

Volume

Fmark

Page 18 of the Quantum Power Wheelchair (9700) user manual — GPIB:Addr (optional)
Pagina 18 · clicca per ingrandire
Pagina 18
Page 18 of the Quantum Power Wheelchair (9700) user manual — GPIB:Addr (optional)
Page 19 of the Quantum Power Wheelchair (9700) user manual — GPIB
Pagina 19 · clicca per ingrandire
Pagina 19

interface is available as an option. All menu settings can be set and retrieved over the

9700. Before using this interface, the address must be set using the GPIB Address menu item. The same command set is used for both the GPIB and RS-232 interfaces.

The serial port is located on the back of the 9700, and uses a 9-pin D-type connector

An optional GPIB (also known as IEEE-488) computer interface is available for the

Both interfaces may be used at the same time. Responses will be made to the most

1. No connection 2. Tx - Transmit (to computer) 3. Rx - Receive (from computer) 4. DTR - connected to pin 6 5. Ground 6. DSR - connected to pin 4 7. RTS - connected to pin 8 8. CTS - connected to pin 7 9. No connection The voltage level of the Transmit signal is +/-10V, the Receive signal should be at

simple command language. The command set is the same for both the RS232 and

All menu items can be accessed and selected via the computer interface using a

The 9700 comes standard with an RS232 serial interface; a GPIB (IEEE-488)

with the following pinout (as viewed from the back of the 9700):

computer interface using a simple command language.

4 Computer Interface

Serial (RS232) Pinout

Command Language

recently used interface.

GPIB interfaces.

least +/-5V.

GPIB

Page 20 of the Quantum Power Wheelchair (9700) user manual — Command Protocol
Pagina 20 · clicca per ingrandire
Pagina 20

ASCII 10), otherwise it returns a ?1 (a question mark, followed by the number "one",

until the carriage return is sent. If an error is made and identified prior to sending the

a carriage return and a line feed). A ?2 is sent if a valid command is received but the

With echo enabled, all characters sent will be echoed back to the sender before the

generator ignoring the command. If the command is properly identified, the pulse

Only one command will be processed per message. Commands are not processed

carriage return, sending a new $ will reset the input buffer and allow a corrected

P <name> is the command name. No spaces are allowed between the $ and the

generator returns an ok followed by a carriage return and a line feed (ASCII 13,

P <##> is an unsigned integer associated with the command. A space must be

Unidentified commands and most out of range conditions result in the pulse

Example - send the following command to set the number of cycles:

To determine the current value of a parameter the syntax is:

P CR is a carriage return character (ASCII value 13).

The pulse generator will return the following:

Echo EnabledMODE 1<cr><lf>

All commands have the following syntax:

Echo Disabledok<cr><lf>

<name>. The name is case sensitive.

inserted between <name> and <##>.

P $ indicates a command follows.

expected response is sent.

parameter is out of range.

Command Protocol

$MODE 1

command to be sent.

Show 4 more labels / short text on this page
ok<cr><lf> · $<name> ?CR · $<name> <##>CR · where
Page 21 of the Quantum Power Wheelchair (9700) user manual — $MODE ?
Pagina 21 · clicca per ingrandire
Pagina 21

Communication parameters are set at 9600 baud, 8 bits, parity = none, and 1 stop bit.

To help establish RS232 communications, the pulse generator emits the characters

BNC approximately every 200 ms after power up and until the 9700 receives a $.

This will return an integer followed by a space, carriage return, and a line feed

Example - the following command would retrieve the current Cycles setting:

Both the GPIB and the RS232 interface may be used at the same time. The

instrument will respond to the port which sent the command.

The pulse generator will return the following:

Echo EnabledMODE ?<cr><lf>
Echo Disabled100<cr><lf>

where name = a valid command name.

Communication Protocol

character (ASCII 10).

$MODE ?

100<cr><lf>

Page 22 of the Quantum Power Wheelchair (9700) user manual — Command List
Pagina 22 · clicca per ingrandire
Pagina 22

Sets the active edge of the Ext/Gate signal when used as

Sets the pulse width, in microseconds*10, for Channel 1. 100 - 100000 T1:Wid

Sets the pulse width, in microseconds*10, for Channel 2 100 - 100000 T2:Wid

Sets the character used as a decimal point on the display. 0 = , (comma) 1 = . (period) Fmark,

Beeps the speaker inside the 9700 the specified number

Resets shot counter. SHOT ? will return the number of

Enables/Disables the RS232 echo. The result string is

Sets the current level, in 10's of mA (100 = 1A), for

Sets the current level, in 10's of mA (100 = 1A), for

Sets the delay, in microseconds*10, for Channel 1. 0 - 999999998 T1:Dly

Sets the delay, in microseconds*10, for Channel 2 0 - 999999998 T2:Dly

Enable / disables the pulse generator output. 0 = Disable 1 = Enable RUN

Sets the key click volume level. 0 - 9 VOLUME

Sets the pulse generator mode. 0 = Single Shot mode 1 = External Trigger mode MODE Description Parameters Command Name 9700 Communication Commands

Recall a stored configuration. 0 - 12 RECALL

Enable/disable Channel 1 0 = Disable 1 = Enable T1:Ena

Enable/disable Channel 2 0 = Disable 1 = Enable T2:Ena

Store a configuration. 1 - 12 STORE

an external trigger. 0 = falling edge 1 = rising edge TRIG

The following table summarizes all the commands:

always sent back. 0 = Disable 1 = Enable ECHO

Channel 1 0 - 2500 T1:Iamp

Channel 2 0 - 2500 T2:Iamp

of times. 1 - 1000 BEEP

shots. 0 = Reset to zero SHOTS

Command List

Page 23 of the Quantum Power Wheelchair (9700) user manual — EXTERNAL TRIG / GATE
Pagina 23 · clicca per ingrandire
Pagina 23

P CHANNELS Two (2) independent outputs, with digitally controlled

P CURRENT 0 to 25A (Bank voltage 44V minimum)

P RATE Dc to 1/ (75ms + largest delay + period)

P TIMEBASE 5MHz, 25PPM crystal oscillator

P THRESHOLD 3VDc (3mA into optoisolator)

P MODES Single shot, external trigger

delay and pulsewidth.

P ACCURACY 100ns + .0001 x delay

P TRIG DELAY Ext Trig to To < 10µs

P TRIGGER SLOPE Rising or falling edge

P DELAY 0 to 99.9999998s

P PULSEWIDTH 100µs to 100ms

INTERNAL RATE GENERATOR

4 SPECIFICATIONS

P IMPEDANCE 1000 Ω

P RMS JITTER 100ns

P RMS JITTER 100ns

EXTERNAL TRIG / GATE

DELAYS

Show 4 more labels / short text on this page
P RESOLUTION 10mA · P ACCURACY 50mA · P RESOLUTION 200ns · P RESOLUTION 200ns
Page 24 of the Quantum Power Wheelchair (9700) user manual — COMPUTER INTERFACE
Pagina 24 · clicca per ingrandire
Pagina 24

P RS232 9600 Baud. All instrument functions and settings may be controlled over the interface bus.

P STORAGE Twelve (12) complete configurations may be stored

and recalled from the front panel or the computer

P OVERSHOOT < 100mA + 10% of pulse amplitude

P POWER < 100W @ 120 or 220VAC

P AMPLITUDE 0-25A (loads 1 - 10 ohm)

P DC CURRENT LIMIT 150mA (each channel)

P PEAK CURRENT 25A per channel

P SLEW RATE > 2.5A/µs

interface.

P IMPEDANCE 1.405 Ω

P WEIGHT 10 lbs.

COMPUTER INTERFACE

OUTPUTS

GENERAL

(T1,T2)

Page 25 of the Quantum Power Wheelchair (9700) user manual — Replacing the Fuse
Pagina 25 · clicca per ingrandire
Pagina 25

A pair of fuses are mounted in the power entry module. To replace fuses, follow the

1. Unplug the 9700 from power source and remove power cord from the back panel.
2. Remove the fuse holder by pushing down on the center tab and pulling out.

Except for fuse replacement, the 9700 should require no maintenance.

3. Remove the faulty fuse and replace with one of a similar rating.
4. Reinstall the fuse holder. 5. Reattach the power cord.

5 MAINTENANCE

Replacing the Fuse

instructions given below:

Page 26 of the Quantum Power Wheelchair (9700) user manual — 5 MAINTENANCE
Pagina 26 · clicca per ingrandire
Pagina 26
Page 26 of the Quantum Power Wheelchair (9700) user manual — 5 MAINTENANCE
Page 27 of the Quantum Power Wheelchair (9700) user manual — 6 CUSTOM FEATURES
Pagina 27 · clicca per ingrandire
Pagina 27

Long Pulse Option Specifications

-10µs - 100ms @ 10A for the duration of the width.

6 CUSTOM FEATURES

Fonti

Riferimenti e link

Pagine di riferimento in questo manuale: produttore, supporto e download.

Fai una domanda su Quantum Power Wheelchair (9700)

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Quantum Power Wheelchair (9700)

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Quantum Power Wheelchair (9700) manuale in PDF

27 pagine·120 KB·Accessorio per computer·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…