Manuale d’uso / di manutenzione del prodotto MKII-BASE16 del fabbricante Q-Logic
Vai alla pagina of 138
GigW orks™ MKII-16 Switch Model MKII-BASE16 Installer ’ s/User ’ s Manual Publication No. 59003-01 Rev . A.
Ancor Communications Incorporated 6130 Blue Circle Drive Minnetonka, MN 55343 (612) 932-4000 Release Number 01, Revision A ( December , 1998) This release obsoletes all previous releases.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A T able Of Contents iii T able Of Contents Preface 1 How to Use This Manual 1 Intended Audience 2 Related Materials 2 Ancor Customer Service 3 Safety Notices 3 Communications Statements 6 Laser Safety Information 9 Accessible Parts 1.
iv T able Of Contents GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual T able Of Contents 3. Switch Management 3-1 Introduction 3-1 GigWorks MKII Switch U.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A T able Of Contents v 3-54 Community T ypes 3-55 Operation T ypes 3-56 Management Information Bases (MIBs) 3-57 Configuring SNMP 4.
vi T able Of Contents GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Appendix C: Chassis Switch Panel C-1 Chassis Switch Panel C-2 Reset C-2 Force Prom .
GigWorks MKII-16 SwitchModel MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Preface 1 Preface How to Use This Manual This manual has five sections and three appendixes: • Section 1 is an overview of the GigW orks™ MKII-16 Switch Model MKII- BASE16.
2 Preface GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Related Materials The following manuals and materials are referenced in the text and/or provide additional information. • The following Fibre Channel Standards: Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.
GigWorks MKII-16 SwitchModel MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Preface 3 Communications Statements Safety Notices A Danger notice indicates the presence of a hazard that has the potential of causing death or serious personal injury .
4 Preface GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Communications Statements radioélectriques por les appareils numériques, telles que prescrites par le Réglement sur le brouillage radioélectrique établi par le ministère des Communications du Canada.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A T able Of Contents 5 VCCI Class A Statement T ranslation: This is a Class A product based on the standard of the V oluntary Control Council For Interference by Information T echnology Equipment (VCCI).
6 Preface GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Laser Safety Information Laser Safety Information The GigW orks 1062/16 MKII Switch may use Class 1 lasers to communicate over the fiber optic conductors.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A T able Of Contents 7 Optical GBICs Each optical GBIC is a single communications port. Each communications port consists of a transmitter and receiver optical subassembly .
8 T able Of Contents GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Labeling Requirements There are no caution or danger labels required for use of the optical GBIC since it is a Class 1 laser component assembly .
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A T able Of Contents 9 Accessible Parts The only Field Replaceable Units (FRUs) in the GigW orks MKII-16 Sw.
10 T able Of Contents GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A General Description 1-1 Section 1 GigW orks™ MKII-16 Switch Model MKII-BASE16 General Description GigWorks™ MKII-16 Switch Model MKII-BASE16 General Description The Switch is the Fabric component of a Fibre Channel compliant network.
1-2 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual General Description • All ports used as F_Ports support Class 1, Class 2, Class 3, and Intermix Fibre Channel service. Refer to the Reference Information appendix for more information.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A General Description 1-3 General Description information about the W eb-based Switch management application.
1-4 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual General Description of these Broadcast Zones. A port will broadcast to all ports in the same Broadcast Zone (or zones) in-which the port is defined.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A General Description 1-5 General Description ordered from Ancor) be placed on each port populated with a GBIC so that the GBICs may be tested.
1-6 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual General Description Figure 1-2 Chassis Front Continuous Test button (Must be OFF .
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A General Description 1-7 General Description Currently , the following GBICs are certified for use: Short-.
1-8 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual General Description Front Panel Controls Power Button Figure 1-2 shows the location of the Power Button. The Power Button is protected by a clear plastic cover that must be flipped UP in order to reach the button.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A General Description 1-9 General Description Following a normal power-up with the Continuous T est button .
1-10 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual General Description time or several times over a short period of time when they are power ed up.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A General Description 1-11 General Description An Input Fuse Holder is incorporated into the AC Input Power Connector assembly .
1-12 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual General Description When the overheated power supply cools down, the power supply will attempt to place itself back in service.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Installation 2-1 Section 2 Installation Installation There are seven basic steps required to install the Switch. 1. Unpack 2. Place or Mount the Equipment 3.
2-2 Installation GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Installation 2. Place or Mount the Equipment The Switch may be placed on a flat surface and stacked or mounted in a 19” EIA rack. The Switch comes physically configured for placing on a flat surface.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Installation 2-3 Installation Philips-head screws, one in each hole in the Side Fillers. c. Mount the Brackets. Refer to Figure 2-2. The Switch is shipped with a package containing cabinet mounting brackets and screws.
2-4 Installation GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Installation 3. Apply the IEC Class 1 Laser Information Label (If the installation is in.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Installation 2-5 Installation 5. Connect to AC Power Danger: An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the Switch chassis.
2-6 Installation GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Installation Danger: This product is supplied with a 3-wire power cable and plug for the user ’ s safety . Use this power cable in conjunction with a properly grounded outlet to avoid electrical shock.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Installation 2-7 Installation Refer to Appendix A in this manual for Switch power requirements.
2-8 Installation GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Step 7 unless the POST passed. 7. Cable N or NL_Port Adapters to the Switch Ports All 16 ports on the Switch may connect to N_Ports. Ports 1, 2, 5, 6, 9, 10, 13, and 14 may connect to NL_Ports or N_Ports.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Installation 2-9 Installation Incorrect Cabling Cabling connected incorrectly will not damage the GBICs or the Switch. N_Port Connections Connect Fiber Channel N_Ports to F_Ports on the Switch.
2-10 Installation GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Installation Most NL_Port connections to the Switch are via Hubs or directly to storage devices such as JBODs and disc arrays.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Installation 2-11 Installation Figure 2-3 Cabling N_Port Rx Tx Rx Tx NL_Port NL_Port NL_Port NL_Port NL_Port NL_Port NL_Port Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx 2 4 6 8 10 12 14 16 1 35 7 9 11 13 15 ON OFF COMMUNICATIONS, INC.
2-12 Installation GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Operating the Switch The Continuous T est button on the front of the Switch chassis and the switches on the Chassis Switch Panel on the back of the Switch chassis are the only operational controls.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-1 Section 3 Switch Management Introduction The Switch supports management through: .
3-2 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Introduction • Configure the desired Port State and read the actual Port State On.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-3 Introduction define the area of Broadcasts. A particular port may be placed in one or more of these Broadcast Zones. A port will broadcast to all ports in the same Broadcast Zone (or zones) in-which the port is defined.
3-4 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Ethernet Cabling The Switch is managed through the use of a customer-supplied management station connected to the Switch via 10BASE-T Ethernet.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-5 Configuring the Switch Ethernet Port Configuring the Switch Ethernet Port Before the Switch can be managed using the Ethernet port, several management parameters must be set correctly .
3-6 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual IP Address. When all parameters have been set correctly , click the Set Parameters Button to set the values on the Switch chassis.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-7 Managing the Switch Using the GigWorks MKII Switch Utilities Managing the Switch Using the GigWorks MKII Switch Utilities The Switch Utilities allow you to manage the Switch through its Ethernet interface.
3-8 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities Switches come configured from the factory with the default address 10.0.0.1.) 3. Use the Setup T ab to read the UAR T statistics to make sure the Utilities can connect to the Switch.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-9 Switch Utilities each tab. The system saves only the contents of the data window of each tab. That is, it does not save such things as button settings.
3-10 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Management Information Management Information Figure 3-2 Management Information T ab Refer to Figure 3-2. The Management Information tab enables you to display all the managed objects provided by the Switch.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-11 Switch Utilities — Management Information in the Ancor W eb-site (www .
3-12 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Management Information Management Information T ab Controls/Windows Port Field Enter the Fibre Channel port number for-which you want to read the SNMP information.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-13 Switch Utilities — Flash Flash Figure 3-3 Flash T ab Refer to Figure 3-3. The Flash tab enables you to load new control code into the Switch’ s Flash memory and also to command the Switch to perform a Reset operation.
3-14 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Flash new Flash code: Y ou may place the cursor in the Flash File Name box and type it, or you may click the Select button.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-15 Switch Utilities — V ersions V ersions Figure 3-4 V ersions T ab Refer to Figure 3-4. The V ersion tab enables you to display and log the Switch hardware and software version numbers.
3-16 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — V ersions memory . This number is loaded as part of the Flash code. Therefore, this number could change following a Flash load.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-17 Switch Utilities — Diagnostics T race Diagnostics T race Diagnostics T race Overview The Diagnostics T race tab allows Ancor service personnel to follow the progress of selected operations as they proceed through the Switch.
3-18 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Diagnostics T race Figure 3-5 Diagnostics T race T ab (Enables) Controls are divided into two groups, Enables and Display .
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-19 Switch Utilities — Diagnostics T race Enables None Button Deselect (remove the highlight from) all Diagnostics T race functions.
3-20 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Diagnostics T race Display Offset Box The Offset is a hexadecimal address of fset into the 4K circular Diagnostics T race Buffer .
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-21 Switch Utilities — Setup Setup Figure 3-7 Setup T ab Refer to Figure 3-7.
3-22 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Setup UDP Port # Box This is the UDP Port Number the Utilities application uses to communicate with the proper application in the Switch.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-23 Switch Utilities — Chassis Configuration Chassis Configuration Figure 3-8 Chassis Configuration T ab Refer to Figure 3-8.
3-24 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Chassis Configuration both numbered beginning with 00. Press the Apply button to apply the Chassis Number to the chassis.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-25 Switch Utilities — Chassis Configuration Administration/Operation States The Administration State is the state you would like the chassis and each of its Ports to be in.
3-26 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Port Status Port Status Figure 3-9 Port Status T ab Refer to Figure 3-9.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-27 Switch Utilities — Port Status Port Field: The Port field lists each port on the Switch. Status Field: The Status field tells whether a port is Online or Offline.
3-28 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Port Status depends on the capabilities of the loop devices and what has happened since the loop was last initialized.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-29 Switch Utilities — Zoning Zoning Figure 3-10 Zoning T ab Zoning allows the user to divide the fabric ports into zones for more efficient and secure communication among functionally grouped nodes.
3-30 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Zoning each zone is fabric-wide) that define which ports receive Name Server information. A particular port may be defined in one or more of these Name Server Zones.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-31 Switch Utilities — Zoning Broadcast Zone Rules: 1.
3-32 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Zoning 6. All ports not defined as being part of any enabled Name Server Zone are Name Server Zone Orphans. Name Server Zone Orphans are all placed in the same Name Server Orphan zone.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-33 Switch Utilities — Zoning overlapping enabled Hard Zone boundaries. Click a checked checkbox to un- check it. When you check a box in a particular zone, the Utilities will automatically check the Enabled checkbox for that zone.
3-34 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Name Server Name Server Figure 3-1 1 Name Server T ab Refer to Figure 3-1 1. The Name Server tab enables you to poll the Switch for Name Server information.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-35 Switch Utilities — Name Server device has registered with the Name Server . This field is blank if there are no registered FC-4 T ypes.
3-36 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Management Configuration Management Configuration Figure 3-12 Management Configuration T ab Refer to Figure 3-12.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-37 Switch Utilities — Management Configuration next time it initializes instead of the values in the saved configuration. Network IP Address: Use the Get IP Config Button to read the current IP Address of the Switch Management port.
3-38 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Switch Utilities — Management Configuration moving your cursor to the field and typing. Y ou may write the contents of this field to the Switch by pressing the Set SNMP Config.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-39 Switch Utilities — Management Configuration Get IP Management V ersion Button: Press to read the current Management firmware version.
3-40 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Managing the Switch Using TFTP Managing the Switch Using TFTP The firmware in the Switch can be upgraded using the T rivial File T ransfer Protocol (TFTP).
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-41 Managing the Switch Using TFTP gateway=0.0.0.0 arpTimeout=30000 snmpReadCommunity=public snmpWriteCommunity=private snmpTrapCommunity=public snmpName= snmpContact= snmpLocation= snmpDoAuthTrap=NO snmpTrapAddress=127.
3-42 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Managing the Switch Using TFTP The new management configuration values will not take effect until the Switch is reset.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-43 Managing the Switch Using TFTP default value for this parameter is the empty string, “”. snmpLocation The value of the SNMP Systems Group SysName variable.
3-44 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Managing the Switch Using TFTP If the Switch load process fails for any reason, the Switch control code saved in the Switch flash is not valid and must be reloaded.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-45 Managing the Switch Using TFTP Loading New Management Interface Code Over an Inval.
3-46 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Managing the Switch Using TFTP T est the Switch File T ransfer Process: (16-Port Switch Only) The file named test on the Switch can be used to test TFTP file transfers.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-47 Managing the Switch Using TFTP Retrieving the Index of V alid Switch File Names: The Switch contains a file called index which lists the valid file names, their file type (binary or text), and their read/write permissions.
3-48 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Managing the Switch Using SNMP Managing the Switch Using the Simple Network Management Protocol (SNMP) Network management is the process of planning, organizing, and controlling a communications-oriented system.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-49 Managing the Switch Using SNMP Figure 3-13 illustrates the four main components involved in network management.
3-50 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Managing the Switch Using SNMP symbols to alert the administrator to problems.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-51 Managing the Switch Using SNMP object identifier , or NULL. NULLs act as place holders reserved for future use. Access This property indicates the level of access to this particular object.
3-52 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Managing the Switch Using SNMP specific. The Ancor MKII Accounting MIB is an enterprise MIB. The Simple Network Management Protocol SNMP is a well-defined, public standard that is widely used by the Internet community .
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-53 Managing the Switch Using SNMP Figure 3-14 Polling-Only Data Collection Interrupt-.
3-54 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Managing the Switch Using SNMP or graphical representation allowing the administrator to easily diagnose and manage the nodes and network traffic.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-55 Managing the Switch Using SNMP T rap Community This name needs to accompany trap messages. If it does not match the name setting on the network management station that receives the traps, the trap messages are rejected and lost.
3-56 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Managing the Switch Using SNMP Management Information Base (MIB) Switch MIB objects consist of 8 functional groups.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Switch Management 3-57 Managing the Switch Using SNMP switch element • fcFeModuleT able — Module T ab.
3-58 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Managing the Switch Using SNMP usually identical to the host name, for example, “switch001”. The default value for this parameter is the empty string, “”.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Diagnostics/T roubleshooting 4-1 Section 4 Diagnostics/T roubleshooting Introduction Section 4 contains information to help you find problems. Power Supply T roubleshooting helps you solve AC power and Power Supply problems.
4-2 Diagnostics/T roubleshooting GigW orks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual T able 4-1 Troubleshooting Matrix (Single Power Supply) ON - OK AC sour.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Diagnostics/T roubleshooting 4-3 T able 4-2 Troubleshooting Matrix (Dual Power Supplies) ON - OK AC sourc.
4-4 Diagnostics/T roubleshooting GigW orks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual For example: 1. Note in T able 4-1 that when there is an AC Source disruption (System Status column) that the fan is OFF and the Power Good and Over T emperature LEDs are OFF .
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Diagnostics/T roubleshooting 4-5 Power-On-Self-T est (POST) Power-On-Self-T est (POST) Overview The Switch checks the state of the Mode switches as part of its power-up procedure.
4-6 Diagnostics/T roubleshooting GigW orks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual For example: • A PROM checksum failure is an example of a fatal error . This indicates that the PROM firmware is corrupt and the Switch may not run.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Diagnostics/T roubleshooting 4-7 Power-On-Self-T est (POST) The POST diagnostic program performs the foll.
4-8 Diagnostics/T roubleshooting GigW orks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Power-On-Self-T est (POST) PROM Checksum Failure (1 Blink) The Switch is not operable. This is a checksum test of the PROM designed to verify the integrity of the PROM data.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Diagnostics/T roubleshooting 4-9 Power-On-Self-T est (POST) functions that can be performed within the confines of an individual ASIC. A failure indicates a faulty Switch ASIC and blinks the Heartbeat LED six times between three-second pauses.
4-10 Diagnostics/T roubleshooting GigW orks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Power-On-Self-T est (POST) Switch Auto-Route T est Failure (10 Blinks) The Switch is operable.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Diagnostics/T roubleshooting 4-11 Power-On-Self-T est (POST) Switch Management Port Failure (14 Blinks) The Switch is operable. The Switch Management Port test verifies the integrity of the Ethernet data bus functionality .
4-12 Diagnostics/T roubleshooting GigW orks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Continuous T est Overview The Continuous T est button (when set to the TST position) causes the Switch to go from normal operate mode to continuous test mode.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Diagnostics/T roubleshooting 4-13 For example: • If the only problem with the Switch is one or more bad GBICs, the POST tests will not detect the problem at power-up because they do not test the GBICs.
4-14 Diagnostics/T roubleshooting GigW orks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual b. If the Heartbeat LED is blinking an error code of eight (8), there is a problem with one or more GBICs. 1. Press the Continuous T est button to place the Switch back in its normal operative (OP) mode.
GigWorks MkII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Diagnostics/T roubleshooting 4-15 Fiber Continuity T ests When there is a problem communicating over a particular fiber link and both the Switch and the N_Port adapter pass their respective tests, check the continuity of the fiber optic cables.
4-16 Diagnostics/T roubleshooting GigW orks MkII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Removal/Replacement Procedures 5-1 Section 5 Removal/Replacement Procedures Introduction The only Field Replaceable Units (FRUs) in the Switch are Input Fuses, GBICs, and the Power Supply(s).
5-2 Removal/Replacement Procedures GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Input Fuse Replacement 1. Insert the Fuse(s) into the Fuse Holder . Refer to the Reference Information appendix for fuse-type information.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Removal/Replacement Procedures 5-3 GBIC GBICs may be removed and replaced with the power on and the Switch operating without disrupting traffic on other ports.
5-4 Removal/Replacement Procedures GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual GBIC 2b. Removing GBICs that have bail-operated latches. Some GBICs have latches that are operated by a built-in bail as represented in the drawing below .
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Removal/Replacement Procedures 5-5 GBIC Replacement GBICs may be removed and replaced with the power on and the Switch operating without disrupting traffic on other ports.
5-6 Removal/Replacement Procedures GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Power Supply Power Supply Removal If the Switch contains two Power Supplies, either supply is “Hot-Pluggable”.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Removal/Replacement Procedures 5-7 Replacement If the Switch contains two Power Supplies, either supply is “Hot-Pluggable”.
5-8 Removal/Replacement Procedures GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Reference Information A-1 Appendix A Reference Information Appendix A contains the specifications for the GigW orks MKII-16 Switch Model MKII-BASE16. Refer to the Switch Overview in Section 1 for the location of all connections, switches, and components.
A-2 Reference Information GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Reference Information FL_Port Characteristics: .
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Reference Information A-3 Reference Information Gb/s, even though backplanes supply up to 32 Gb/s. Maximum Frame Sizes: ............. Model MKII-BASE16 — 2148 bytes (21 12- byte payload) for all classes of service supported by the Switch.
A-4 Reference Information GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Reference Information Switch Agent : .
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Reference Information A-5 Reference Information Switch Environmental Operational T emperature: ............ 10 to 40°C (50 to 104°F) Operating Humidity: .
A-6 Reference Information GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Reference Information Shortwave Laser GBIC (multi-mode) Connector: ................................... Duplex SC Color coding: ...
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Reference Information A-7 Reference Information Copper Inter-Enclosure GBIC (active) Connector: .
A-8 Reference Information GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Reference Information 2.362 (.093") 475.437 (18.718") 480.16 (18.904") Front View Back View Dimensions in mm (inches) 447.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Reference Information A-9 Figure A-2 GigW orks MKII-16 Switch Model MKII-BASE16 Dimensions (T op V iew) 447.04 (17.6”) Dimensions in mm (inches) 20.701 (.
A-10 Reference Information GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Ancor Customer Service B-1 Appendix B Ancor Customer Service Appendix B contains information about Ancor Customer Service.
B-2 Ancor Customer Service GigW orks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Ancor Customer Service Software Support Ancor actively supports the current software/firmware release and the prior release for 6 months following the general availability date for the current release.
GigWorks MKII16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Chassis Switch Panel C-1 Appendix C Chassis Switch Panel Chassis Switch Panel Refer to Figure C-1 for the location of the Chassis Switch Panel.
C-2 Chassis Switch Panel GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Chassis Switch Panel Reset Refer to Figure C-2. Figure C-2 Reset Button Use the Reset button only under the direction of your service representative.
GigWorks MKII-16 Switch Model MKII-BASE16 Installer's/User's Manual 59003-01 Rev . A Chassis Switch Panel C-3 Chassis Switch Panel W atch Dog Timer Disable Refer to Figure C-3. The Switch contains a W atchdog timer that resets the internal processor in the event of a hangup.
C-4 Chassis Switch Panel GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev . A Installer's/User's Manual Chassis Switch Panel Chassis #, Fabric #, Stage #, and Area # Configuration Switches The Chassis #, Fabric #, Stage #, and Area # configuration switches (shown in Figure C-5) are not used.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Q-Logic MKII-BASE16 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Q-Logic MKII-BASE16 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Q-Logic MKII-BASE16 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Q-Logic MKII-BASE16 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Q-Logic MKII-BASE16, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Q-Logic MKII-BASE16.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Q-Logic MKII-BASE16. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Q-Logic MKII-BASE16 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.