RK5000PS-3U/RK5000-3U Rack Mount Chassis





The product and/or manual may bear the following marks:.
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
In order to maintain compliance with FCC regulations shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and television reception.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

The RK5000PS-3U rack mount chassis supports fiber optic modules. The chassis has 12 slots and an internal double-width power supply. You can insert up to 12 single-width modules or a combination of single-width and double-width modules into the slots. For redundancy, you can use the optional external power supply (EPS5000-120). It provides redundant power for up to two fully populated RK5000PS-3U chassis. You can mount the chassis, which is 3 rack units (RU) high, into an EIA-standard, 19-inch rack.
The RK5000-3U chassis has 14 slots and requires an external power supply. You can insert up to 14 single-width modules or a combination of single-width and double-width modules into the slots. You can mount the chassis, which is 3 rack units (RU) high, into an EIA-standard, 19-inch rack. You can use the optional EPS5000-120 external power supply, which consists of dual 120 watt, hot swappable power supplies, to power up to two fully populated RK5000-3U chassis. The EPS5000-120 is 1 RU high and rack mountable.
You can fill the empty module slots on either chassis with single-width blank modules (RK5001B-3U) and double-width blank modules (RK50002B-3U).
RK5000PS-3U Rack mountable chassis with power supply, 3 RU
RK5000-3U Rack mountable chassis, 3 RU; external power supply required

Rack Ears (2) Power Supply Module Slots (12) Alarm from Module LED Power Fail LED Pelco Badge

Figure 1. RK5000PS-3U Front View
Thumbscrews for Fastening Modules (12) External Connector for Redundant Power Supply Relay Output Connector with Screw Terminal Power Button Power Cord Connector

Figure 2. RK5000PS-3U Back View

Rack Ears (2) Module Slots (14)

Figure 3. RK5000-3U Front View
External Connector for Redundant Power Supply Thumbscrews for Fastening Modules (14)

Figure 4. RK5000-3U Back View

PACKAGE CONTENTS
1 Rack mount chassis
4 Screws and washers for rack mounting
1 Rack mount chassis
4 Screws and washers for rack mounting
The procedure for mounting an RK5000PS-3U and an RK5000-3U into a rack is exactly the same. To mount a chassis, follow these steps and refer to Figure 5.

Figure 5. Mounting an RK5000PS-3U/RK5000-3U into a Rack

You can install single-width or double-width modules into the empty slots on the RK5000PS-3U chassis and RK5000-3U chassis. To install a module, follow these steps and refer to Figure 6.


Figure 6. Module Installation
You can use single-width or double-width blank modules to fill the empty module slots on the chassis. To attach a blank module, follow these steps and refer to Figure 7.

Figure 7. Blank Module Installation

REMOVING THE POWER BUS
You must remove the power bus from the RK5000PS-3U if you want to use the power supplies that are provided with the Fiber modules.
To remove the power bus, follow these steps and refer to Figure 8.

Figure 8. Power Bus Removal

You can easily replace the internal power supply in the RK5000PS-3U in case of failure. The front of the power supply has two LEDs. The top LED turns red when there is an alarm condition from one of the modules. The bottom LED turns red when the power supply fails. To replace an internal power supply, follow these steps and refer to Figure 9.


Figure 9. Internal Power Supply Replacement

ELECTRICAL
Input Voltage 100-240 VAC
Input Current 1.0 A
Output Voltage 12 VDC
Output Current 10 A
Fuse Rating 1.6 A
Redundant Capability Yes with optional EPS5000-120 power supply
Number of Slots 12 for modules and 2 for power supply
Operating Temperature 32° to 122°F (0° to 50°C)
Operating Humidity 80% maximum relative humidity, noncondensing
Storage Humidity 95% maximum relative humidity, noncondensing
Dimensions 5.22” H x 18.99” W x 8.85” D (13.26 x 48.23 x 22.48 cm)
Mounting Fits 19-inch, EIA-standard rack
Unit Weight 8.01 lb (3.63 kg), with power supply 25.53 lb (11.58 kg), fully populated
MECHANICAL
Number of Slots 14 for modules
Dimensions 5.22” H x 18.99” W x 8.85” D (13.26 x 48.23 x 22.48 cm)
Mounting Fits 19-inch, EIA-standard rack
Unit Weight 5.19 lb (2.35 kg), chassis only 25.63 lb (11.63 kg), fully populated

WARRANTY
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
If a warranty repair is required, the Dealer must contact Pelco at (800)þ289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product lia- bility, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
Manual # Date Comments C1972M 11/04 Original version. C1972M-A 10/06 Added Warning to Description section and Mounting a Chassis section. Revised electrical specifications.
Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco. © Copyright 2006, Pelco. All rights reserved.

3500 Pelco Way Clovis, California 93612 USA
Australia | Canada | Finland | France | Italy | Russia | Singapore | Spain | Sweden | The Netherlands | United Arab Emirates | United Kingdom | United States
Worldwide Headquarters
Pagine di riferimento in questo manuale: produttore, supporto e download.
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.
Invia la prima domanda: risponderanno altri possessori o il nostro team.