Manuale d’uso / di manutenzione del prodotto DD1900 del fabbricante Pelco
Vai alla pagina of 20
SB19/SB1900 Series Discr eet Surveillance Enclosures Installation/Operation Manual C467M-D (5/95) ® Pelco • 3500 W. Pontiac Way, Clovis, CA 93612-5699 • USA • www.
REVISION HISTORY Manual # Date Comments C467M 2/90 Original Version. C467M 3/90 Rev. A. “Scope” section expanded to include warnings. Updated model and options section. Figure 5 Added. C467M 11/90 Rev. B. Addendum incorporated @ Figure 19 Exploded Assy Diagram.
Pelco Manual C467M-D (5/95) 1 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
2 Pelco Manual C467M-D (5/95) 2.0 SCOPE The information contained within this manual covers the SB19/SB1900 Series of Discreet Surveillance En- closures.
Pelco Manual C467M-D (5/95) 3 Figure 1. SB1900 Series Wiring Diagram.
4 Pelco Manual C467M-D (5/95) 4.3 MOUNTING INSTRUCTIONS Determine the type of mounting desired. The enclo- sure can be mounted in a hard ceiling, completely re- place a standard 2' x 2' suspended ceiling tile using the APSB19 optional faceplate, or be inserted through a cut-out in a standard 2' x 2' suspended ceiling tile.
Pelco Manual C467M-D (5/95) 5 7. Slide the back box through the ceiling tile and mounting plate and replace the four (4) 1/4-20 bolts and tighten to secure the back box to the mounting plate. 8. Check the alignment of the back box to the ceiling tile by attaching the 12.
6 Pelco Manual C467M-D (5/95) 13. Attach the dome to the pan/tilt by aligning the two ball studs protruding through the flange of the dome with the two holes in the dome attachment brack- ets and engaging the studs. 14. Attach the safety chain on the side of the back box to the short 4-40 threaded screw in the 12.
Pelco Manual C467M-D (5/95) 7 4.3.1.2 Suspended Ceiling Tile Replacement Mounting T o mount the enclosure into a suspended ceiling grid where the tile is replaced, perform the following steps. 1. Determine the location for mounting the enclosure and remove the appropriate ceiling tile.
8 Pelco Manual C467M-D (5/95) 12. Attach the safety chain on the side of the back box to the short 4-40 threaded screw in the 12.5" round faceplate trim with the provided hardware. 13. Attach the faceplate trim to the back box by align- ing the two serrated studs with two of the holes in the edges of the back box and engaging the studs.
Pelco Manual C467M-D (5/95) 9 12. Attach the faceplate trim to the back box by align- ing the two serrated studs with two of the holes in the edges of the back box and engaging the studs. 13. Operate the pan/tilt to verify that there are no ob- structions or dragging cables within the back box or dome.
10 Pelco Manual C467M-D (5/95) 5.0 CARE AND MAINTENANCE Regularly scheduled maintenance will prolong the op- erational life and appearance of the equipment. IMPORT ANT : The lower dome of the en- closure is an optical surface. When cleaning the inner surface of the dome and viewing window , treat as carefully as you would a fine camera lens.
Pelco Manual C467M-D (5/95) 11 6.0 EXPLODED ASSEMBL Y DIAGRAM Refer to Figure 7 for an exploded assembly diagram of the SB19 enclosure. Figure 7. SB19 Exploded Assembly Diagram PP ONL Y NON SL ONL Y *.
12 Pelco Manual C467M-D (5/95) 7.0 EXPLODED ASSEMBL Y MECHANICAL PARTS LIST Item Qty Description Pelco Part Number 1 1 UL, Pad, camera, black .062" thick EH200010004 2 1 PCB assembly , pan/tilt PCB3000100ASSY 3 1 Bushing, 3/8" tilt shaft PT180010001 4 1 Shaft, tilt table PT18004002COMP 5 1 Sprocket .
Pelco Manual C467M-D (5/95) 13 7.0 EXPLODED ASSEMBL Y MECHANICAL PARTS LIST (continued) Item Qty Description Pelco Part Number 48 Not used 49 Not used 50 Not used 51 1 Slip ring, 24 circuit for presets 250010000 52 Not used 53 Not used 54 Not used 55 1 Bracket, tilt pot PT18044012COMP 56 1 Bracket, LPP lens connector PT18044013COMP 57 1 Gear , 1.
14 Pelco Manual C467M-D (5/95) 8.0 MODELS DD1900 Dome drive unit for SB1900. (UL) DD1900-PP Dome drive unit for SB1900-PP . DD1900-SL Dome drive unit for SB1900-SL.
Pelco Manual C467M-D (5/95) 15 9.2 MODELS SB1900, SB1900-SL, SB1900-PP AND SB1900SL-PP CM7500 Series Coaxitron Matrix Switcher/Control System rack mount card cage with CPU and power supply . Capable of up to 64 inputs and up to 4 monitor outputs. (See C584 product specifi- cation sheet for details).
16 Pelco Manual C467M-D (5/95) Pan Speed: 24 ° /sec ± 1 ° T ilt: -9 0 ° movement from horizontal plane T ilt Speed: 12 ° /sec ± .5 ° Maximum Load: 10 lbs (4.
Pelco Manual C467M-D (5/95) 17 12.0 W ARRANTY AND RETURN INFORMA TION This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE).
18 Pelco Manual C467M-D (5/95) Pelco 3500 Pelco Way • Clovis, CA 93612-5699 (559) 292-1981 • (800) 289-9100 FAX (800) 289-9150 or (559) 292-3827 International customers call 1-559-292-1981 or FAX 1-559-348-1120 (Product specifications subject to change without notice.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco DD1900 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco DD1900 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco DD1900 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco DD1900 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco DD1900, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco DD1900.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco DD1900. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco DD1900 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.