INST ALLA TION/OPERA TION WCS1-4 Environmental Power Supply C561M-F (8/06).
2 C561M-F (8/06) Important Safeguards and W arnings 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Installation should be done only by qualified serv ice personnel and conform to all local codes.
C561M-F (8/06) 3 Description The WCS1-4 is a single power supply designed for indoor or outdoor applicatio ns and is ideal for use with cameras, domes, and integrated positioning systems such as Spectra ® and Esprit ® . The WCS1-4 power supply has one fused output and is capable of handling up to 4 amps (100 VA) of total load.
4 C561M-F (8/06) Installation MOUNTING INSTRUCTIONS T o mount the power supply directly to a wallboard, wall, or concre te refer to Figure 1 through 3 and do the following: 1. Remove the retaining screw from the door latch of the WCS1-4 power supply .
C561M-F (8/06) 5 FUSE INSTALLATION The WCS1-4 power supply is shipped from the fa ctory with a 1.6-amp fuse installed for 100/120 V AC input power . T o use input power of 240 V AC, c hange the 1.
6 C561M-F (8/06) OUTPUT WIRING T o install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the following: 1. Refer to T able A and determine the output connection needed for your camera, dome, or positioning system.
C561M-F (8/06) 7 CABLE CONNECTIONS AND REQUIREMENTS T able A. Wiring Distances The following are the recommended maximum distances to wire the WCS1-4 to a Spectra III or Esprit positioning system. T o determine the correct voltage tap: 1. Pick the unit type.
8 C561M-F (8/06) Maintenance There are no user -serviceable parts except for the fuse. If the transformer in the WCS1-4 does not work properly , the entire environment al power supply needs to be retu rn ed to the factory for repair . Refer to the W arranty and Return Information for instructions on returning the WCS1-4.
C561M-F (8/06) 9 Specifications ELECTRICAL Input V oltage Selectable 100, 120, 240 VAC, 50/60 Hz via the Primary Line Input connector strip Output V oltage/Power Selectable 24 VAC (T ap A), 26 VAC (T ap B), or 28 V AC (T ap C) at 100 VA via the Secondary Output T ap’ s connector strip Fusing One fuse.
10 C561M-F (8/06) Figure 5. WCS1-4 D imensi on Draw ing The materials used in the manufacture of this document and its compo nents are compliant to the requirements of Directive 2002/95/EC.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, witho ut charge, any mer c handise proved defective in ma terial or wo rkmanship for a period of one year after th e date of shipment.
W orldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco C561M-F è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco C561M-F - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco C561M-F imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco C561M-F ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco C561M-F, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco C561M-F.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco C561M-F. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco C561M-F insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.