Manuale d’uso / di manutenzione del prodotto M3W del fabbricante Omron
Vai alla pagina of 18
Check following components! Vérifier les composants suivants ! Prüfen Sie folgende T eile des Lieferumfangs! Controllare i componenti indicati di seguito! ¡Compruebe los siguientes componentes! Co.
c d 2 1 L F a b J G H I J K L A B C D E F This product is designed to measure the blood pressure and pulse rate of people within the range of the designated arm cuff, following the instructions in this instruction manual. It is mainly designed for general household use.
1 EN Import ant Safety Info rmation Consult your doctor prior to using in pre gnancy or if d iagnosed with ar rhythmia or arteriosclerosis. Please read this s ection carefully b efore using the unit. W arning: • Indicates a potentially hazardous situation which, if not avo ided, could re sult in deat h or ser ious injury .
2 Impo rtant Sa fety In form ation (AC Adapter Usage) • Use only the original AC adapter (optional) designed for this unit. Use of unsupported adapt ers may damage and/ or may be hazardous to the unit. • Plug the AC adapter into t he appropriate volt age outlet.
3 EN 1. Overview Main uni t Display O/I ST AR T ( ) button User A/B but ton Up/Down ( ) buttons Buzzer and Date/T ime setting ( ) button Air Jack Battery compartment AC adapter jack (for optiona l AC .
4 2. Prep aration 2 . 1 Inst alling/Replaci ng the Batteries 1. Remove the battery cover . 2. Insert four “AA” batteries as indicated in the battery comp artment and then replace the battery cover . Notes: • If the ba ttery low s ymbol ( ) appea rs on the display , turn t he unit of f then replace all bat teries at the same time .
5 2. Pr epar atio n EN 2 . 2 Setting the Buzzer/ Date and T i me 1. Pr es s th e butt o n . 2. Set the Buzz er . 3. Set the monitor to t he correct date and time before t aking a measurement for the first time . 4. Press t he O/I ST ART button to st ore the setting.
6 3. Using the Unit 3 . 1 Applying the Arm Cuff Remo ve tight- fittin g clo thin g or t ight r olled up sl eeve f rom y our u pper a rm. Do no t pl ace th e cuff over thic k cloth es. 1. Insert the air p lug into the ai r jack . 2. Put your arm through the cuff loop.
7 3. Using the Unit EN 3 . 2 How to Sit Correctly T o take a meas urem ent, y ou n eed to b e rel axed a nd com fortably seate d, under com fortable room t emper ature. No eati ng, smok ing or exer cisin g 30 mi nutes befo re taking a m easurem ent. • Sit on a ch air with you r feet flat on the floor .
8 3. Using the Unit 3 . 3 T aki ng a Rea din g Notes: • T o can cel a m easurem ent , pre ss the O /I ST AR T b utto n to tu rn o ff the unit a nd to rel ease t he air i n the arm cuf f.
9 3. Using the Unit EN Notes: • During measurement, the buzzer (if se t to “on”) wi ll beep in rhythm with yo ur heartbeat. • W ai t 2- 3 min ute s be fore t aki ng a not her bloo d pr essu re measu rem ent.
10 3. Using the Unit 4. Remove the arm cuff. 5. Press t he O/I ST AR T button to turn off the monitor . The m onitor automa tic ally s tores the me asur ement i n its memor y .
11 3. Using the Unit EN • Y our blood pressure m onitor includes an irre gular heartbeat feature. Irregular heartbeats can influence the result s of the measurement. The irregular heartbeat algorithm automatically determines if the measurem ent is usable or needs to be repeated.
12 3. Using the Unit 3 . 4 Using the Memo ry Function The m onitor automa tical ly s tores the r esult up to 6 0 sets for ea ch user ( A and B ). It can also ca lcul ate an a vera ge re ading b ased o n th e meas urem ents from the las t thr ee rea dings taken wit hin 10 min ute s.
13 3. Using the Unit EN T o V iew the Rea dings S tored in Memory 1. Press the bu tton, whi le the average val ue is dis played. Th e Memo ry nu mber appear s for a sec ond befo re the pul se rate is di splay ed. T he newe st set is nu mbe red “ 1”.
14 4. T roubl eshoot ing and Mai nt enance 4 . 1 The Icons and Error Messages Error Display Cause Remedy Irregular or weak pulses ar e detected. Remov e the arm cuff. W ait 2-3 minutes and then take another measurement. Repeat the steps in se ction 3.
15 4. Tr oublesh ootin g and Maintena nce EN Note: The irre gular heartbeat s ymbol ( ) may also be disp layed with er ror mess ages. Cuf f is under inflated. Carefully read and repeat the steps li sted under sectio n 3.3. Movement dur ing m easurement.
16 4. Tr oublesh ootin g and Maintena nce 4 . 2 T rou bleshooting Problem Cause Rem edy The reading is extremely low (or high). Arm cuff not applied correctly . Apply the ar m cuf f c orrectly . Refer to section 3.1. Movem ent or t alking during measurem ent.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Omron M3W è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Omron M3W - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Omron M3W imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Omron M3W ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Omron M3W, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Omron M3W.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Omron M3W. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Omron M3W insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.