MD12 50 T A CTIC AL INFLA T ABLE SIDE POUCH LP.
DO NO T REMO VE PRIOR T O S ALE Warning: This document is for the use of licensed users only . No part of this document may be reproduced, transmitted, or transcribed in any form or by any means without the express permission of Mustang Survival Corp.
C ONTENTS Introduction ................................................................................................... 1 Product Familiarization and Readiness ....................................................... 2 Readiness Checklist ..........
INTRODUCTION This manual provides instructions and guidelines for safely using and maintaining Mustang Survival MD1250 T actical Inflatable Side Pouch Life Preservers (LPs). The MD1250 LP provides flotation capability with minimum bulk or interference using separate, independently operated left and right LPs.
PRODUCT F AMILIARIZA TION AND READINESS The MD1250 T actical Inflatable Side Pouch LPs are used in right/left pairs, and can be attached to an LE belt, or integrated P ALS webbing and MOLLE vest. Right-hand LPs have the letter R on the attachment webbing straps (Figure 2); left-hand LPs have the letter L.
R eadiness Checklis t If the inflat or expiry date has p assed, Must ang Survival r ecommends wat er te sting the MD1250 LP t o become familiar with it s in-wat er functionality . When all boxes are checked, the LP is ready for use: F Status indicator is green.
2. Release the attachment webbing straps on the back of the LP by pulling up on each strap just below the bottom edge of the pull-the-dot snap. 3. Feed the attachment webbing straps on the back of the LP through the P ALS webbing. 4. Reattach the pull-the-dot snaps by pushing down on the top edge of the snap opposite the dot.
4. Release the mouthpiece, and turn the locking ring counterclockwise to close the inflator valve and lock the mouthpiece in place. DONNING THE INFLA TED LP Once the LPs have been inflated through manual, automatic, or oral inflation, tuck the inflated cells underneath each arm (Figure 6).
4. Release the mouthpiece, and turn the locking ring counterclockwise to close the inflator valve and lock the mouthpiece in place. 5. Complete repacking of the LP – see Repacking the LP . RE - ARMING THE LP CA UTION: The MD 12 50 LP must be deflat ed befor e being re-armed.
12. Ensure that the status indicator on the replacement inflator cap is green, the lanyard for the beaded manual inflation handle is present, and the locking ring is locked. 13. T o test for leakage, inflate the LP using the oral inflator tube – see Inflating the LP .
10. Ensure the bladder fabric is wrapped tightly around the CO 2 cylinder and the hydrostatic inflator (Figures 14–16). 11. Remove the vacuum fitting from the oral inflation tube. 12. Detach the automatic/manual conversion cap (MA7219) from the hydrostatic inflator .
Final P acking 1. Ensure the opening in the cover fabric is secured around the hydrostatic inflator . The water inlet valve should be easily accessible.
• Visually inspect the expiry date on the hydrostatic inflator . If the expiry date has passed, replace the inflator – see Re-arming the LP . T esting f or Leak s Perform this test every 180 days, or more frequently if the LP is exposed to extreme conditions.
T esting the A utomatic In flat or NO TE: A left/ right pair of fully armed MD12 50 LPs and t wo MA7 214 -10 re- arm kits are requir ed for this t est. 1. Attach the LPs to the left and right sides (see W earing the LP). 2. Enter water of an appropriate depth to keep the head above the surface.
A CCE SS ORIES MA7214-10 Re-Arm Kit: 33 gram CO 2 replacement cylinder and inflator cap (two kits required for each pair of MD1250 LPs) MA7219 Auto/Manual Conversion Cap GLOSSARY T erm Definition LP L.
Mustang Survival and seahorse design is a register ed trademark of Mustang Survival Corp. Our commitment to quality has earned our Bur naby facilities ISO 9001 registration, the highest of all international standards. This is our guarantee you are r eceiving the ultimate in design and manufacturing.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Mustang Survival MD1250 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Mustang Survival MD1250 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Mustang Survival MD1250 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Mustang Survival MD1250 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Mustang Survival MD1250, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Mustang Survival MD1250.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Mustang Survival MD1250. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Mustang Survival MD1250 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.