Datalogger ™ DataLogger and DataPulse Software Instruction Manual Febuary 2005 © Copyright 2005 Magnetek.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 1 of 16 ©2005 ELECTROMOTIVE SYSTEMS All rights reserved. This noti ce applies to all copyri ghted mate rials included with this product , including, but not li mited t o, this manual and software embodied wit hin the product.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 2 of 16 Section 1: Overview The DataLogger Series 3 was designed to simplify troubleshooting and provide for detailed operational histories that are necessary for genuine preventive maintenance.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 3 of 16 How data logging works: The DataLogger is a device which polls the Drive via the RS232 CN1 port. Once connected, the logger will r ead the Inverter Status and U1 parameters. From the Inve rter Status, the logger can detect when the drive is running or when a fault or alarm occurs.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 4 of 16 Logging of Run, Fault, Alarm and Trace Data All Data collection is automatic, viewing data is per the various screens, and the roadmap of functions per the diagram on the Menu Navigation on page 6.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 5 of 16 14912, 14920, 14940, 14960, 14961, 14962, 14964, 14965, and 14980. For connection to Series 3 drives, simply replace the keypad with the data logger. The DataLogger will automatically begin logging after a 2 second boot up.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 6 of 16 DATALOGGER MENU NAVIGATION -Main Menu- Monitor Fault History Alarm History Run History Upload from VFD Download from VFD Clear Data Settin.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 7 of 16 The Monitor Mode provides for Real-Time di splay of Inverter operation. It also indicates the total number of Run events, Alarm and Fault events.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 8 of 16 The Fault History provides the data for reviewing recorded faults and information on each fault occurrence. -FAULT HISTORY - Flt: 1 OF 6 Run: 5 Ext Fault S7 01/16/04 02:37 01/28/04 08:44:13 - FAULT HISTORY - U2-03: 030.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 9 of 16 The Alarm History provides the data for reviewing recorded alarms and information on each alarm occurrence. -ALARM HISTORY - Alm: 1 OF 26 Run: 1369 Upper Limit1 Err 01/16/04 15:14 01/28/04 08:44:13 Date & Time: Used to time stamp all history and trace data.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 10 of 16 The Run History provides the data for reviewing information on each time the drive receives a run command or a change in direction. -RUN HISTORY - Run: 220 OF 260 Forward 01/16/04 15:14 Duration: 40 Secs 01/28/04 08:44:13 Date & Time: Used to time stamp all history and trace data.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 11 of 16 Introduction to DataPulse Series 3 software DataPulse is a user friendly, Windows based, DataLogger communication software that will allow the viewing of logger data in a spreadsheet format.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 12 of 16 Navigating DATAPULSE Series 3 MENU Upload data from Datalogger View parameter data View Run data View Alarm data View Fault data Uploadin.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 13 of 16 Viewing parameter sets Selecting the button will display the parameter sets that are stored in the logger. Double click on the parameter set of inte rest and the parameter information is displayed.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 14 of 16 Displaying Drive History Data Selecting the button will display the fault history window. Selecting the button will display the alarm history and selecting the button will display the run history window.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 15 of 16 Select the data that you want to di splay by selecting in the check box..
Impulse DataLogger Series 3 Instruction Manual 2/1/05 16 of 16 PRINTING It is best to print only the desired informati on from the thousands of pieces of data stored in the logger. To edit and print this information, you would save the file as a *.CSV file which is a “comma separated variable” file.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Magnetek Series 3 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Magnetek Series 3 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Magnetek Series 3 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Magnetek Series 3 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Magnetek Series 3, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Magnetek Series 3.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Magnetek Series 3. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Magnetek Series 3 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.