WS -2811U- IT Wireless Professi onal Weather Center Operations Manual Revision: 10.
Page | 2 T A B L E O F C O N T E N T S TABLE OF CONTENTS………………………… ………………………………………….……………...2 INTRODUCTION………………………………… ………………………………………… ….
Page | 3 The following Weather Alarms can be adjusted in AL ARM set mode…………..…20 Default Weather Alarm values……………… ……………………………………….. ……20 Pressure Alarms………………………………… ………………………………… …….
Page | 4 ongratulations on purchasing this state- of -the-art weather station. Featuring time, date, weather forecast, wind gust and wind speed, indoor/outdoor temperature and humidity, air pressure and rainfall, this weather station will provide various weather information and weather forecasts.
Page | 5 I N V E N T O R Y O F C O N T E N T S Carefully open the package and check that the following contents are complete: Wind Sensor TX63U- IT Rain Sensor TX58UN- IT Thermo-Hygro Sensor TX59UN-1-.
Page | 6 F E A T U R E S : W I R E L E S S D I S P L A Y Time display in 12/24 hour time format Automatic time and date (PC time) update from USB transceiver if connected; otherwise, user must.
Page | 7 100% solar-powered with built-in rechargeable alkaline power cell (not replaceable). High-efficient solar panels maintain operation throughout all seasons Transmission range: 200 .
Page | 8 5. Setup troubleshooting: If the sensor data fails to display for any of the outdoor sensors within 10 minutes, (“ - - - “ is displayed), remove the batteries from all units for 1 minute and start the Setup procedure again at Step 1.
Page | 9 W I N D S E N S O R The wind sensor must be installed with the front of the sensor (the solar panel) facing true South , or the reported wind direction will not be accurate. Mount within the 200 -foot wireless range of the thermo-hygro sensor and on the same side of the house.
Page | 10 F U N C T I O N K E Y S : S E T K E Y Press and hold for 3 seconds to enter the SET mode, where the following can be changed: LCD contrast, Manual time setting, 12/24 hour time display, .
Page | 11 Press to display minimum and maximum records of various weather data Stop the weather alarm when ringing M O D E 1 D I S P L A Y : Press the SET key to toggle between Mode 1 and .
Page | 12 M A N U A L S E T T I N G S : Press and hold the SET key for 3 seconds to enter the SET mode. The display will automatically return to Mode 1 display in 30 seconds if a key is not pressed. While in SET mode, each press of the SET key will advance to the next SET mode item: 1.
Page | 13 1 2 / 2 4 H O U R T I M E D I S P L A Y S E T T I N G : The time can be set as 12-hour or 24 -hour format. To change the time display: 1. The "12h" or "24h" digits will flash. 2. Press the ▲ UP ARROW key or ▼ DOWN ARROW key to toggle the value.
Page | 14 1. Press the ▲ UP ARROW key or ▼ DOWN ARROW key to toggle between the unit “inch” or “mm” 2. Press the SET key to confirm and to enter the RELATIVE AIR PRESSURE UNIT SETTING R E L A T I V E A I R P R E S S U R E U N I T S E T T I N G The relative air pressure can be set as inHg (inches of mercury) or hPa (hectopascal).
Page | 15 S T O R M W A R N I N G T H R E S H O L D V A L U E S E T T I N G A storm warning is displayed by flashing of the down weather tendency arrow when the air pressure decreases a specified amount over six hours. The sensitivity value for the storm warning display can be set between .
Page | 16 Press the MIN/MAX key or the ALARM key to exit SET mode, or Simply wait 30 seconds until the SET mode times out and returns to the Mode 1 display.
Page | 17 Press the ALARM key to enter ALARM mode. Subsequent presses of the ALARM key will advance to the next weather alarm section. Note: Weather alarms can also be set from the Heavy Weather Pro software. Consult the Heavy Weather Pro Software User’s Guide for instructions.
Page | 18 6. Press the ALARM key once. The Low Pressure alarm display will be shown. 7. Press and hold the SET key for about 2 seconds. The pressure digit will flash . 8. Press the ▲ UP ARROW key or ▼ DOWN ARROW key to set the low-pressure alarm value.
Page | 19 O U T D O O R T E M P E R A T U R E A L A R M S 1. The high outdoor temperature alarm display will be shown. 2. Press and hold the SET key for about 2 seconds. The temperature digit will flash. 3. Press the ▲ UP ARROW key or ▼ DOWN ARROW key to set the high outdoor temp alarm value.
Page | 20 W I N D D I R E C T I O N A L A R M Multiple wind direction alarms can be set simultaneously if desired. 1. The wind direction alarm display will be shown.
Page | 21 H Y S T E R E S I S To compensate for fluctuation of the weather data, which may cause the weather alarm to ring constantly if the measured reading is close to the alarm level, a hysteresis function has been implemented for each weather alarm.
Page | 22 If the icon displayed is a sun or raining cloud, there will be no change of icon if the weather gets any better (with sunny icon) or worse (with rainy icon) since the icons are already at their extremes. The displayed icon forecasts the weather in terms of getting better or worse and not necessarily sunny or rainy as each icon indicates.
Page | 23 A I R P R E S S U R E H I S T O R Y G R A P H The LCD shows the relative air pressure value and the air pressure history on a bar graph. Press the SET key to toggle between Mode1 and Mode2 of the display. Mode 1 : The bar graph displays the air pressure history of the past 24 hours in seven steps.
Page | 24 Mode 2 displays the following wind data: Wind direction Wind chill in F or C Wind gust in mph, km/h, bft, knots or m/s R A I N F A L L M E A S U R E M E N T The 1hour, 24 -hour, week, month or total rainfall measurement is displayed on the LCD, in the unit of inch or mm .
Page | 25 To reset the rainfall reading, press the ▲ UP ARROW key. The total rainfall amount will be reset to 0, and the time is updated to current time. Note: Until the first rainfall total reset is performed, the time and date of the total rainfall are displayed as "- - -.
Page | 26 O U T D O O R T E M P E R A T U R E / D E W P O I N T - 40 °F to +139.8°F with 0.2°F resolution -9.9°C to +59.9°C with 0.1°C resolution ( “OF.
Page | 27 O U T D O O R D A T A R E C E P T I O N Temperature and humidity data every 13 seconds Wind data every 17 seconds Rain data every 19 seconds A I R P R E S S U R E 8.86 inHg to 32.46 inHg 300 hPa to 1099 hPa Relative pressure pre-set range : 27.
Page | 28 L I A B I L I T Y D I S C L A I M E R The electrical and electronic wastes contain hazardous substances. Disposal of electronic waste in wild country and/or in unauthorized grounds strongly damages the environment.
Page | 29 F C C S T A T E M E N T Statement according to FCC part 15.19: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.
Page | 30 W A R R A N T Y I N F O R M A T I O N La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship.
Page | 31 For warranty work, technical support, or information contact: La Crosse Technology, Ltd 2817 Losey Blvd. S. La Crosse, WI 54601 Customer Support: www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il La Crosse Technology WS-2811U-IT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del La Crosse Technology WS-2811U-IT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso La Crosse Technology WS-2811U-IT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul La Crosse Technology WS-2811U-IT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il La Crosse Technology WS-2811U-IT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del La Crosse Technology WS-2811U-IT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il La Crosse Technology WS-2811U-IT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo La Crosse Technology WS-2811U-IT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.