CONTENTS Getting Started ----------------------------------------------------------------------- 2 Setup Procedures --------------------------------------------------------------------- 3 Setup Menu--.
Getting Started Installing Keyboard Wedge Scanner To install a keyboard wedge scanner, follow the steps listed below: 1) Make sure that the scanner has the correct Y (U)- cable for the system (a PC or.
Setup Procedures 1) Locate a group that contains the parameters to be changed. 2) Scan the “Enter Group # ” label. The scanner will sound beeps indicate that setup is in progress 3) Scan the label representing the parameter to be changed 4) Scan the “Exit” to end the group currently selected, the scanner will sound beeps.
Setup Flow Chart Set All Defaults Show Version ENTER GROUP SELECT ITEMS EXIT 4.
Group 0: Interface Selection KEYBOARD RS-232 WAND OCIA RS-232 Reserved 2 DTMF Reserved 4 ENTER GROUP EXIT 5.
Group 1: Device Selection for Keyboard Interface PC/AT, PS/2 50,60,70,80(*) PC/XT PS/2 25, 30 (NEC 9801) (IBM 5550) (PS 55) (NEC N5520) (ACER 7300) (KW1050D/CT-700A/WANG 5120) (WANG 5425) (MAC_SE) (LC.
Group 1: Device Selection for Keyboard Interface (IBM3196,3197,3476,3477) Reserved Q Reserved R Reserved T IBM3197 IBM 3476 IBM3477 RESERVED 5 Reserved 6 RESERVED 7 Reserved 8 RESERVED 9 ENTER GROUP E.
Group 2: Intercharacter Delay Start Keyboard Setting Scan Enter Group 2 Label -- > Scan Start Keyboard (or RS-232) Setting Label --> Scan two digits labels in "Table-Hex" --> Scan E.
Group 3: Language for Keyboard Interface U.S. (*) ENGLAND FRANCE GERMANY ITALY BELGIUM SWEDEN/FINLAND SPANISH DENMARK PORTUGAL SWISS NORWAY ENTER GROUP EXIT 9.
Group 3: Language for Keyboard Interface CANADA HOLLAND POLAND LATIN JAPAN RESERVED 1 RESERVED 2 RESERVED 3 (IBM THINK-PAD FOR JAPAN) (PANASONIC CF-II FOR JAPAN) ENTER GROUP EXIT 10.
Group 4: Terminator KEYBOARD NONE CR SPACE TAB ESC CTRL-C ESC ENTER GROUP EXIT 11.
Group 4: Terminator RS-232 NONE CR CR/LF LF SPACE TAB ESC CTRL-C STX..ETX XON.. XOFF EOT ENTER GROUP EXIT 12.
Group 5: Scan Mode 1: Trigger On/Off 2: Trigger On/Good Read Off (*) 3: Trigger On/Good Read Off/ Delay Timeout = ? 4: Continuous/Trigger Off 5: Continuous/LED Always on 6: Continuous/No Trigger 7: Co.
Group 5: Scan Mode FLASH OFF(*) FLASH ON SHORT ZONE LONG ZONE LASER DELAY For Laser Scanner Mode Default Laser Delay Timeout = 60 sec. Scan Enter Group 5 Label Scan Laser Delay --> Refer to the Table-Hex at page 41 and select a value --> Scan Confirm in Table Hex.
Group 6: Preamble and Postamble Preamble Postamble Preamble & Postamble Setting: Scan Enter Group 6 Label --> Scan Preamble or Postamble Label --> Refer to ASCII Table(page 44), scan two digits in Table-Hex (Page 43) Representing one character, maximum 10 characters can be accepted.
Group 8: RS-232 Parameters Baud Rate 300 600 1200 2400 4800 9600(*) 19200 38400 Data Bit BIT 7 BIT 8 ENTER GROUP EXIT 16.
Group 8: RS-232 Parameters Parity : NONE (*) ODD EVEN Handshaking: NONE (*) XON/OFF Scanner Ready Data Ready ACK/NAK ENTER GROUP EXIT 17.
Group 8: RS-232 Parameters (CK/NAK Response Time CTS Observation Time:) 100 ms 300 ms 500 ms 1 sec. 3 sec (*) 5 sec. 10 sec. 00 ENTER GROUP EXIT 18.
Group 9: CODE 39 / (CODE 32) Enable (*) Disable Standard (*) Full ASCII Transmit Start/End Character Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*) E.
Group 9: CODE 39 / (CODE 32) Verify Normal (*) Verify Strick ENTER GROUP EXIT 20.
Group 10-1: Interleaved 2 OF 5 Disable (*) Enable Transmit Check Character Disable Enable (*) Verify Checksum Disable Enable Length Define Min: 4 Barcode Length Setting Max: 48 Scan Enter Group 10-1 L.
Group 10-2: Industrial 2 OF 5 / IATA Disable (*) Enable Transmit Check Character Disable Enable (*) Verify Checksum Disable Enable Length Define Min: 2 Barcode Length Setting Max: 24 Scan Enter Group .
Enable Group 10-3: Matrix 2 of 5 Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*) Length Define Min: 2 Barcode Length Setting Max: 40 Scan Enter Group .
Scan Confirm Label in Table Hex --> Scan Exit Label Group 10-4: CHINA POSTAGE Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*) Length Define Min: 2 .
Scan Confirm Label in Table Hex --> Scan Exit Label Group 11: CODE 128/(CODE 93)/(CODE 11)/(MSI-PLESSEY) CODE 128 Enable (*) Disable CODE 93 Enable Disable (*) Concatenation Enable Disable (*) ENTE.
Note: Options marked by ( ) are only available upon request Group 11: CODE 128/(CODE 93)/(CODE 11)/(MSI-PLESSEY) Enable(*) Disable Number of Check Character One Two (*) Transmit Check Character Enable.
Note: Options marked by ( ) are only available upon request Group 12: (ISBN/ISSN) Disable (*) Enable ENTER GROUP EXIT 27.
Note: Options marked by ( ) are only available upon request Group 13: CODABAR / NW7 Enable(*) Disable Transmit Start/End Character Disable (*) Enable Start/End Transmit Type ABCD/ABCD ABCD/TN*E abcd/a.
Group 14: (Code 4) Enable Disable (*) ENTER GROUP EXIT 29.
Note: Options marked by ( ) are only available upon request Group 15-1: EAN-13/JAN-13 Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading .
Check-Digit On (*) Check-Digit Off Group 15-2: UPC-A Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Digit Disable (*) Enable Truncate.
Group 15-3: EAN-8/JAN-8 Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Disable (*) Enable EAN Convert to EAN-13 Disable (*) Enable EN.
Group 15-4: UPC-E / UCC EAN/128 Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Digit Disable (*) Enable UCC/EAN/128 Disable (*) Enabl.
Disable Enable Group 16: General Parameters Upper Case Lower Case Universal ALT Mode Buzzer Pitch (Default : 16) Buzzer Duration (Default: 04) Buzzer Pitch & Buzzer Duration Setting: Scan Enter Gr.
Turbo (*) Normal Group 17: Code ID Setting CODE 39 INTERLEAVED 2 OF 5 INDUSTRIAL 2 OF 5 MATRIX 2 OF 5 CHINA POSTAGE CODE 128 CODE 93 CODE 11 MSI/PLESSEY CODABAR/NW7 EAN-13/UPC-A EAN-8 UPC-E UPC-A ENTE.
Note: Refer to ASCII Table, scan two hexadecimal labels in Table Hex to represent one character Group 18: WAND Type Parameters BAR=LOW BAR=HIGH(*) Scan Speed Lowest Low (*) High Highest Data Format Tr.
Group 19-1: (Magnetic Parameters) Disable Enable (*) Track Order Track 1/2/3 (*) Track 1/3/2 Track 2/1/3 Track 2/3/1 Track 3/2/1 Track 3/1/2 ENTER GROUP EXIT 37.
Note: Options marked by ( ) are only available upon request Group 19-1: (Magnetic Parameters) Track Selection Track 1&2&3 any (*) Track 1 only Track 2 only Track 3 only Track 1 and 2 Track 2 a.
Note: Options marked by ( ) are only available upon request Group 19-2: (Magnetic Parameters) Start Sentinel: (SS) Tk1 Default : % Tk2 Default Tk3 Default: ; ? End Sentinel: (ES) Tk1&2&3 Defau.
STX - Tk1 Start Sentinel - Tk1 Data - End Sentinel - Tk1 - DLE STX - Tk2 Start Sentinel - Tk2 Data - End Sentinel - Tk2 - DLE STX - Tk3 Start Sentinel - Tk3 Data - End Sentinel - Tk3 - DLE Note: Optio.
2: To scan a function key barcode label, full CODE 39 must be enabled. Please refer to Full CODE 39 Table to produce the function key barcode label. Full CODE 39 Enable Function Code for PC XT/AT F1 (.
Function Code for PC XT/AT Enter ($M) End ($U) ($B) Tab ($N) PgUp ($V) BS ($O) PgDn ($W) Up ($P) Ins ($X) Down ($Q) Del ($Y) Left ($R) Esc (%A) Right ($S) 42.
Home ($T) Table-Hex : HEXADECIMAL 0 1 2 3 4 5 6 7 8 9 A B C D 43.
E F Confirm ASCII TABLE 44.
Hexadecimal-Decimal Conversion Table 45.
For Example: Hexadecimal Decimal 56 -> H:5 L:3 83 D5-> H:D L:5 213 PIN ASSIGNMENTS COLOR Function 9 Pin DSUB/AM P (F) 25 PIN DIN(M) 6 PIN DIN (M) 6 PIN MINI DIN (M) Yellow Start of Scan 1 --- 6 .
PIN ASSIGNMENTS RS-232 Signal Output COLOR FUNCTION 9 PIN DSUB/AMP(F) 25PIN DSUB(F) Black GND 5 7 Brown CTS 7 4 Grey RTS 8 5 Violet RX 3 2 Green TX 2 3 Red VCC+5V 9 25 Note : For PC applications , a cable with DC power jack is required to accept external power input.
48.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Konig CMP-BARSCAN30 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Konig CMP-BARSCAN30 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Konig CMP-BARSCAN30 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Konig CMP-BARSCAN30 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Konig CMP-BARSCAN30, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Konig CMP-BARSCAN30.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Konig CMP-BARSCAN30. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Konig CMP-BARSCAN30 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.