F F o o r r c c e e 4 4 G15 & G15+ RAID Systems 15-bay Rackmount and T ower Enclosures Installation Guide May 31, 2002 • Revision A Patent Pending.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A II Copyright Copyright 2000, 2001 by JMR Electronics, Inc. All Rights Reserved.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A T able of Contents 1. Intr oduction FOR TRA Product Family Features . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 FOR TRA Force 4 G15 RAID System Components .
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A Option Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4 Delayed Start Option Jumper . . . . . . . . . . . . . . . . . . . .
The FOR TRA F F o o r r c c e e 4 4 G15 & G15+ RAID Systems are prepackaged 2G Fibre to 2G Fibre RAID solutions designed to be used with the included Intel PCI Dual 2G Fibre Channel host controller to provide a high-end RAID system solution.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A FOR TRA F F o o r r c c e e 4 4 products use advanced mid-plane technology developed by JMR, which allows power supplies, drives, and all other enclosure components to interface into a single board.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A T ower Specifications Dimensions/Weight Unit W eight 43 lbs. (19.5kg) Height 20-1/2" (521mm) W idth 9-5/8" (235mm) .
ID Selection 0-127 device ID addresses are addressable and can be easily set-up via ID rotary switches located on the personality modules. For specific connection and installation information, refer to Chapter 4 .
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 2-1 This chapter covers specification information for all FOR TRA F F o o r r c c e e 4 4 G15 T ower and G15+ Rackmount or T ower enclosures.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A Disclaimer The original product packaging has been tested and is safe under normal shipping circumstances. Reshipping the product without using the original product packaging will void the warranty .
SYS-FL T The SYS-FL T LED on the back of the unit indicates an error on the SES bus. It also indicates whether an active loop connection is established.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 3-1 This chapter covers Fibre Channel device installation for both the FOR TRA F F o o r r c c e e 4 4 G15 and G15+ rackmount and tower enclosures.
Follow the steps in reverse to reinstall. Drive Installation Device mounting screws are included with the unit for device mounting. The JMR part number for the #6-32" mounting screws is HDS-01906. 1. After removing the canister , place it on a static free surface along with the device to be installed.
4. Repeat steps 1 through 3 until all devices are installed, then move onto step 5 to complete unit setup and installation. 5. Configure ID and other options as required. See Chapter 4 for Fibre Channel device setup. 6. Install and configure SES and other optional features.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 4-1 This chapter covers Fibre Channel device configuration and option settings. The FOR TRA F F o o r r c c e e 4 4 G15 and G15+ have built-in SES on the personality card.
Setting ID Rotary switch settings only affect Slot 0 and all other slots are sequentially increased by a value of one after that slot. The ID is set sequentially starting from a base address. The base address, or starting address, is set via a 0-7 position rotary switch located on the back of the unit.
1G Option Setting By setting the rotary switch settings to “7” - “F”, the enclosure will operate in 1G mode. Both the upper set of switches and lower set of switches must be set to the same value. The drive ID’ s will revert to the default value of 0-14 and can not be changed.
Delayed Start Option Jumper Header W1 pins 1 & 2. Jumper on = enabled. Jumper off = disabled (default). Remote Start Option Jumper Header W1 pins 3 & 4. Jumper on = enabled. Jumper off = disabled (default). Front Status LEDs A status indicator is located on each canister .
External I/O Connection The external I/O connections are located on the personality card There are four SFP tranceiver connectors accessible from the rear of the unit. CH-A and CH-B (T op) Input and output connections for Loop 1. These are SFP (2Gb/s) transceiver connectors used to connect to a host system or to an expansion chassis.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A Mute This is a push button used to silence the Audible Alarm. SYS Activity LED This is an LED for SES that will blink wheneve.
This chapter covers all operations of the blowers for FOR TRA F F o o r r c c e e 4 4 G15 and G15+ units. Refer to Chapter 1 for blower specifications.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 5-2 User ’ s removing or installing a blower must be awarre of the blower access hole. Contact with the access hole must be avoided while the blower is running to prevent injury .
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 6-1 This chapter covers all operations of the power supplies. For operation, the AC cord (included) must be connected to the AC Inlet on each supply , and the power supply must be switched ON.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A Low Power Mode (Standby Power) When both power supplies are turned off, the unit will switch to low power or standby mode and the power supply fans will continue to run.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 7-1 This chapter covers the installation of the Rackmount enclosure into a standard 19" (483mm) wide and 30" (762mm) to 36" (914mm) deep cabinet that meets the EMA/RETMA standards.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 7-2 Rail Mounting Kit Hardware • T en #10-32 Screws • Four each #8-32 Screws/W ashers/Nuts Spare Hardware Parts Check with a JMR Sales Representative for pricing and availability of spare hardware parts.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 2. Affix the extension bracket to the rear of the unit using two #10-32 screws. There are 3 holes in the extension bracket for mounting. Depending on the hole pattern that is being used in the cabinet, two holes should always be available for securing the extension bracket.
4. Slide the unit into the cabinet and secure it to the cabinet with a single #10-32 screw on each side. 5. Snap the end cap over the screw on each side of the unit to finish the installation.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 8-1 For bus management, the FOR TRA F F o o r r c c e e 4 4 G15 and G15+ 2G Fibre channel enclosures have a built-in SES processor designed to meet the SFF-8067 specification.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 9-1 This chapter covers the installation of the Intel PCI RAID Controller that is shipped with the FOR TRA Force 4 G15 and G15+ RAID Systems.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 10-1 For current information on this product, including updates to the manual and technical support related issues, please contact the sales support section of our web page at www .
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A A-1 Drive Manufacturers Fujitsu Internet Address: www .fcpa.com Hitachi Internet Address: www .hitachi.com IBM (International Business Machines Corporation) Internet Address: www .
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A Host Bus Adapter Manufacturers Adaptec, Inc. Internet Address: www .adaptec.com Antares Microsystems Internet Address: www .antares.com Emulex Corporation Internet Address: www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il JMR electronic PUB-00281 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del JMR electronic PUB-00281 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso JMR electronic PUB-00281 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul JMR electronic PUB-00281 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il JMR electronic PUB-00281, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del JMR electronic PUB-00281.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il JMR electronic PUB-00281. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo JMR electronic PUB-00281 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.