Manuale d’uso / di manutenzione del prodotto S84H-4552-00 del fabbricante IBM
Vai alla pagina of 66
S84H-4552-00 IBM Mobile Systems Hardware Maintenance Manual SelectaDock II Supplement November 1996 Use this supplement with the IBM Mobile Systems Hardware Maintenance Manual.
.
S84H-4552-00 IBM Mobile Systems Hardware Maintenance Manual SelectaDock II Supplement November 1996 Use this supplement with the IBM Mobile Systems Hardware Maintenance Manual IBM.
Note Before using this information and the product it supports, be sure to read the general information under “Notices” on page 56. First Edition (November 1996) The following paragraph does not a.
ThinkPad SelectaDock Docking System Copyright IBM Corp. 1996 iii.
iv IBM Mobile Systems HMM.
Contents ThinkPad SelectaDock Docking System ..... i i i Read This First .................. 1 General Preparation . . . . . . . . . . . . . . . . 3 Checkout Guide . . . . . . . . . . . . . . . . . 4 How to Run the Diagnostics ............ 1 1 Symptom-to-FRU Index .
vi IBM Mobile Systems HMM.
Read This First Before you go to the checkout guide, be sure to read this section. Important Notes Only certified trained personnel should service the computer . Be extremely careful during write operations such as copying, saving, or formatting.
5. Failure symptoms, error codes appearing on display, and beep symptoms 6. Procedure index and page number in which failing FRU was detected 7. Failing FRU name and FRU number 8.
General Preparation Note In this manual, Base Model means the SelectaDock Base Model I, SelectaDock means the SelectaDock II, and SelectaDock Docking System means the Base Model and SelectaDock when docked together as one unit. 1. The SelectaDock supports the ThinkPad 760E, 760ED, and 760ELD.
Checkout Guide Use the following procedure as a guide for computer problems. Note The diagnostic tests are intended to test only IBM products. Non-IBM products, prototype cards, or modified options can give false errors and invalid system responses.
Symptoms (Verified) Go to POST detected an error and displayed numeric error codes. “Symptom-to-FRU Index” on page 18, and then use the Numeric Error Codes table. The diagnostic test detected an error and displayed a FRU code. “Diagnostic Error Codes” on page 21.
Power Supply If the power-on indicator is not on but the power supply fan is not turning, check the power cord for continuity and correct installation. If the power cord is not the problem, either the power supply is defective, or another component is defective causing the power supply to cut off.
Power Supply Connector .1/ and .4/ Power Supply Connector .2/ Power Supply Connector .3/ Pin V dc Red cord + 5 V Yellow cord + 12 V Pin Signal V dc Min. V dc Max. 1, 2 CVCC + 19 V + 21 V 3, 4 GND – – Pin Signal V dc Min. V dc Max. 1 − 12 V − 11.
Power Supply Connector .5/ 1 19 20 2 Pin Signal V dc Min. V dc Max. 2, 3 GND — — 4 SUB 12 + 11.4 + 12.6 5 GND — — 6, 7 + 12 volts + 11.4 + 12.6 8 GND — — 9—11 + 3.
System (except the SCSI hard disk). The FDD-2 or PCMCIA-2 icons represent the FDD or PCMCIA attached through a port replicator or in the SelectaDock Docking System. Printer Test the printer by connecting it to the computer before testing it on the SelectaDock Docking System.
If the external display is attached to the display adapter: 1. Display adapter 2. Main card of SelectaDock Docking System 3. Riser card If the screen is not rolling, do the following to run the display self-test: 1. Power-off the computer on the SelectaDock Docking System and the external display.
External Keyboard Notes If a mouse or other pointing device is attached, remove it and see if the error symptom goes away. If the symptom goes away, the mouse or other pointing device is defective. The computer keyboard does not work when an external keyboard is connected.
3. Select a device and press Enter to run the test. 4. The test progress screen appears. 5. OK appears when the test ends without any errors. 6. Start the Advanced Diagnostic test by pressing Ctrl + A on the basic diagnostic menu screen. 7. Select Tool to install the tools.
PC Test Card LED: The green LED on the PC test card lights when the PCMCIA test is running. If the LED does not light, check that the card is installed correctly by reseating the card. If it still does not light after reseating, try using another slot for the test.
Testing the Expansion Unit 1. The Test Selection Menu appears when you select Test Expansion Unit on the Main Menu . 2. Select an item on the screen and follow the instructions that appear on the screen. Testing the SCSI Subsystem Note If a SCSI adapter is installed in an PCI adapter card slot, remove it before running the SCSI diagnostic program.
2. If the initialization fails, the following screen appears: SCSI Subsystem Diagnostics Utility V2.1 Enter F3=Exit SCSI Initialization Failed If the initialization ends successfully, the following screen appears. Select an item. 3. The SCSI Devices Test Menu appears.
SCSI CD-ROM SCSI optical drive No device The SCSI controller of SelectaDock Docking System appears as ID7 on the screen. 4. If a SCSI device exists and a test medium is required to test the SCSI device, the following pop-up menu appears (shows the case of a SCSI tape drive).
7. The test begins and the following pop-up menu appears: 8. If the test is successful, the following appears: If the test is unsuccessful, the following appears: 1 7.
Symptom-to-FRU Index The Symptom-to-FRU Index lists error symptoms and possible causes. The most likely cause is listed first. Note Replace the FRUs one at a time in the sequence shown in the FRUs of the SelectaDock Sequence of Action column.
Numeric Error Codes Symptom or Error FRUs of the SelectaDock Sequence of Actions 10X, 11X 101: Interrupt failure. 102: Timer failure. 103: Timer interrupt failure. 104: Protected mode failure. 105: Last 8042 command not accepted. 107: NMI test failure.
Symptom or Error FRUs of the SelectaDock Sequence of Actions 6XX 1. Before changing any devices, run the diagnostic test. (See the “How to Run the Diagnostics” on page 11.) 2. FDD external attachment kit 3. Diskette drive assembly 4. Riser card 11XX, 12XX 1 .
Diagnostic Error Codes A detected error is shown as in the following example: A large X to the left of the device icon Device ID (three digit) FRU code (four digit) Error code (two digit) The device ID and error code are used to indicate the detail portion of the FRU which caused the error.
Icon Device ID Suspected Device 068 External hard disk drive FDD-1 1 006 Diskette drive FDD-2 2 066 External diskette drive PCMCIA-1 1 080 PCMCIA PCMCIA-2 2 088 External PCMCIA Parallel 009 Parallel S.
FRU Codes: If an error is detected by the diagnostic tests, a four-digit FRU code is displayed. The FRU code indicates two suspected FRUs. Replace the FRU that is indicated by the two leftmost digits first; then replace the FRU that is indicated by the two rightmost digits.
Beep Symptoms Symptom or Error FRUs of the SelectaDock Sequence of Actions Beep sounds continuously. 1. Verify that the ThinkPad model is correct. (See “General Preparation” on page 3.
Power-Related Symptoms Symptom or Error FRUs of the SelectaDock Sequence of Actions Although the computer is powered off, the fan of the SelectaDock power supply is running.
PC-Card-Related Symptoms Symptom or Error FRUs of the SelectaDock Sequence of Actions PC Card does not work. 1. Reseat the PC card. 2. Check that: a. The PC card is functional when installed in the computer or another SelectaDock. b. The PC card is correctly set up, including the computer resource assignments and device driver installation.
Audio-Related Symptoms Symptom or Error FRUs of the SelectaDock Sequence of Actions Audio equipment does not work. Verify that: 1. The audio equipment works when connected directly to the computer. 2. The audio equipment is designed to be supported by this product.
Adapter-Related Symptoms Symptom or Error FRUs of the SelectaDock Sequence of Actions The adapter does not work. Verify that: 1. The adapter is designed for the docking station adapter slot. 2. The system resources are assigned correctly by its utility program, if the adapter card is a non-PnP ISA adapter bus type.
Intermittent Symptoms Symptom or Error FRUs of the SelectaDock Sequence of Actions An intermittent problem occurs. The problem can be difficult to analyze because it occurs intermittently. If your docking station has such a problem, verify that: 1. The computer is firmly attached to the docking station.
Undetermined Problems Use the following procedure when the diagnostic tests do not identify the failing adapter or device. Check that all cables, wires, and connectors are connected so that they do not cause a short circuit. If any problems are found, reconnect or replace them.
Feature Description Game Switch: This switch controls the MIDI/joystick port. The Sound Blaster cannot be used when the MIDI/joystick is enabled because of data conflict. Set the game switch to the OFF position to disable the MIDI/joystick port. Set the game switch to the ON position to enable the MIDI/joystick port.
Product Overview: The following provides an overview of the system features: Feature Description PCI or ISA slot Two full size PCI slots or one ISA shared slot Bays 1-inch-high bay – ThinkPa.
Removal and Replacement This section contains information on removals and replacements, as well as locations. The arrows in the removals and replacements show the direction of movement to remove a field replaceable unit (FRU), or to turn a screw to release the FRU.
1010 Base Model Make sure that the security key is set to the Unlock position .1/ and release the latch .2/ ; then undock the Base Model. 2 3 1 34 IBM Mobile Systems HMM.
1020 Option Card Cover / Option Card 1 If an option card is installed, remove it. 2 3 3 5.
1030 PC Card 36 IBM Mobile Systems HMM.
1040 1-Inch-High Bay Base Model (1010) The customer can install the ThinkPad option by using the UltraBay tray and HDD, FDD, or CD-ROM by using the device tray in the 1-inch-high bay.
Device Tray 1 2 3 4 5 38 IBM Mobile Systems HMM.
1050 Half-Height Bay Frame Base Model (1010) 1 2 3 3 9.
1060 Upper Cover Base Model (1010) Rear Panel / Option Card Cover (1020) 1-Inch-High Bay (1040) Half-Height Bay Frame (1050) Caution Make sure all power cords are unplugged before you remove the upper cover. Step Length (Quantity) Memo .
When replacing: The following figure shows the route of the microphone cable: The cable goes through here Inside view 4 1.
1070 Bracket Base Model (1010) Rear Panel / Option Card Cover (1020) 1-Inch-High Bay (1040) Half-Height Bay Frame (1050) Upper Cover (1060) Step Length (Quantity) Memo .
1080 Speaker Assembly Base Model (1010) Rear Panel / Option Card Cover (1020) 1-Inch-High Bay (1040) Half-Height Bay Frame (1050) Upper Cover (1060) Bracket (1070) 1 3 2 Step Length (Quantity) Memo .
1090 Power Supply Base Model (1010) Rear Panel / Option Card Cover (1020) 1-Inch-High Bay (1040) Half-Height Bay Frame (1050) Upper Cover (1060) Bracket (1070) Step Length (Quantity) Memo .
1100 Cables Base Model (1010) Rear Panel / Option Card Cover (1020) 1-Inch-High Bay (1040) Half-Height Bay Frame (1050) Upper Cover (1060) This step is a preparation for removing the main card assembly. Remove the IDE cables .1/ , the SCSI cable .
1110 Shield Cover Base Model (1010) Rear Panel / Option Card Cover (1020) 1-Inch-High Bay (1040) Half-Height Bay Frame (1050) Upper Cover (1060) Bracket (1070) Step Length (Quantity) Memo .1/ M 2.6 x 7 mm (3) .2/ M 2.6 x 6 mm (5) .
1120 Main Card Assembly Base Model (1010) Rear Panel / Option Card Cover (1020) 1-Inch-High Bay (1040) Half-Height bay Frame (1050) Upper Cover (1060) Bracket (1070) Cables (1100) Shield Cover (1100) Step Length (Quantity) Memo .
1130 Audio Card / Main Card / Riser Card Base Model (1010) Rear Panel / Option Card Cover (1020) 1-Inch-High Bay (1040) Half-Height Bay Frame (1050) Upper Cover (1060) Bracket (1070) Cables (1100) Shield Cover (1100) Main Card Assembly (1120) .
Locations Front View .1/ Multiuser lock .2/ PC Card lock .3/ SelectaDock base lock .4/ Docking guide .5/ Half-height bay .6/ Status indicators .7/ UltraBay tray eject hole .8/ 1-inch-high bay .9/ UltraBay tray .1ð/ FDD connector .11/ HDD connector .12/ UltraBay tray lock .
Front View (continue) .16/ IDE connector .17/ Internal SCSI connector .18/ Audio device connector .19/ Audio device connector .2ð/ Power supply connector 50 IBM Mobile Systems HMM.
Side View .1/ Volume knob .2/ Headphone jack .3/ Line-out jack .4/ Speaker-in jack .5/ MIDI/joystick port .6/ PCMCIA slots .7/ SCSI connector 5 1.
Rear View .1/ Power jack .2/ PCI connector .3/ ISA connector 52 IBM Mobile Systems HMM.
Parts List 5 3.
1 Connector cover 73H7450 2 Rear cover 39H7441 3 Bezel (See Upper cover group ) 4 Half-height bay frame 82H6729 5 Cable group 73H7453 6 Riser card 39H7442 7 Main card assembly 39H7443 8 Audio card 39H.
Power Cords 1 2 3 4 5 6 7 8 9 10 Warning Use the power cord certified for your country. 1 Colombia, U.S., Venezuela 13F9959 Japan, 2-pin 6454377 Japan, 3-pin 65F0031 2 Hong Kong, Singapore, U.
Notices References in this publication to IBM products, programs, or services do not imply that IBM intends to make these available in all countries in which IBM operates. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used.
.
IBM Part Number: 84H4552 Printed in U.S.A. S84H-4552-ðð.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il IBM S84H-4552-00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del IBM S84H-4552-00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso IBM S84H-4552-00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul IBM S84H-4552-00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il IBM S84H-4552-00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del IBM S84H-4552-00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il IBM S84H-4552-00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo IBM S84H-4552-00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.