Manuale d’uso / di manutenzione del prodotto ICC-801PL del fabbricante Hunter Fan
Vai alla pagina of 40
Commercial Irrigation Controllers Owner’ s Manual and Installation Instructions for all 8 Station Base Models ■ ICC-800PL Plastic Cabinet ■ ICC-801PL Plastic Cabinet (International) ■ ICC-800M.
.
TAB LE OF CO NTE NTS ............................................................................................................. INTRODUCTION AND INSTALLATION Introduction .............................................................................
TAB LE O F CONTE NTS (continued) ....................................................................................... Programming The Controller .......................................................................................................
1 I NTRO DU CTI O N ....................................................................................................................... Finally, there ’ s an affordable, full-featured indoor/outdoor controller for commercial applications.
2 A 1 2 3 4 10 9 8 11 13 14 15 17 16 19 18 12 B B C 5 6 7 I C C COM PO N E NTS ........................................................................
3 This section will give you a brief overview of some of the components on the ICC. Each item will be discussed in further detail later, however this section can be helpful in getting acquainted with the different options available. A – LCD Display 1.
4 I C C COM PO N E NTS – WI R I NG CAB I N ET ............................................................................. 9V Battery 21 20 24 22 23 25.
5 D – Wiring Cabinet 20. 9-Volt Battery – The alkaline battery keeps time during power outages or if the transformer is disconnected. The user may also program the controller without AC power. 21. Reset Button – This button will restart the computer in case of power surge or display freezing.
6 M O U NTIN G TH E C O NTRO LLER TO WALL .......................................................................... ICC Controller Plastic Cabinet Screw with Screw Anchor Cutaway View Wall Mount for Plastic, Metal or Stainless Steel Cabinet All necessary hardware is included for most installations.
7 Finish Grade ICC Pedest al Concrete (Slope to Drain) 3 / 4 " (19 mm) Conduit for 120/230 V AC 1 1 / 4 ", 1 1 / 2 " or 2" (32, 40 or 50 mm) Conduit For V al ve Wires ICC Controller Met al Cabinet PE DE ST AL M O U NTIN G TH E C O NTRO LLER .
8 C ON N E CTI N G V AL VES ............................................................................................................ Valve Common Wire Valve 4 Valve 3 Valve 2 Valve 1 Valve Wires 1. Route valve wires between control valve location and controller.
9 CO N N E CTI N G AC POWE R (IC C-8 00) .................................................................................... It is recommended that a licensed electrician perform the following power installation. 1. Remove the cover from the junction box.
10 1. Remove the cover from junction box. 2. Strip 1 / 2 " off of each wire. 3. For all connections, route the wires through the conduit opening inside the junction box. 4. For 120 volt connections see Figure 3. For 230 volt connections see Figure 4.
11 CO N N E CTI N G ST A TI O N MO D U LE S ...................................................................................... The ICC controller is supplied with one factory-installed station module for up to 8 stations.
12 9V Battery 9V Battery C ON N E CTI N G TH E BA TTE R Y (O PTIO NAL) ......................................................................... Connect a 9-volt alkaline battery (not included) to the battery terminals and place in the battery compartment in the controller cabinet.
13 Common Wire Master Valve Master Valve Wire Power Module CO N N E CTI N G A MASTE R V AL VE ......................................................................................... NOTE: Complete this section only if you have a master valve installed.
14 C ON N E CTI N G A PU M P ST ART RE LA Y ................................................................................ Common Wire Master Valve Wire Power Module PSR Series Pump Start Relay T o Pump 15' Minimum (4.5 m) NOTE: Complete this section only if you have a pump and pump start relay installed.
15 Power Module Weather Sensor CO N N E CTI N G A WEA TH E R S E N S OR (N OT I N C LUD E D) ................................................... A Hunter Mini-Clik ® rain sensor or other type of micro-switch weather sensor may be connected to the ICC.
16 C ON N E CTI N G AN S R R OR I CR R E M OTE CO NTRO L (N OT I N C L U D ED) ......................... Controller Receiver Outdoor Installation (T emporary Connection of Receiver Only) Indoor Instal.
17 1 CO N N E CTI N G TH E SR P PROG RAM M E R (N OT I N CLUD E D) ............................................ POWE R F AI LUR E S ...................
18 S PR I NK LE R SYSTE M FUN DAM E NT ALS ............................................................................. Valve 1 Station 1 Station 2 Station 3 Station 6 Valve 2 Valve 3 Valve 5 ICC Con.
19 PRO G RAM M I N G FUN DAM E NT ALS ..................................................................................... Program Begins at 6:00 AM 12 6 3 9 12 6 3 9 Program Ends at 6:40 AM Station .
20 C R EA TI N G A W A TE R I N G SC H E D U LE ................................................................................... It is usually good to water one or two hours before sunrise. Water pressure will be at optimum levels during the early morning and the water can soak into the roots of the plants while evaporation is minimal.
21 PROGRAM A CALENDAR DA Y ODD/EVEN DA Y SU MO TU WE TH FR SA ODD EVEN LOCA TION 1 ST A TION ST A TION RUN TIME PROGRAM ST ART TIMES HUNTER ICC INTERV AL DA Y PROGRAM B PROGRAM C PROGRAM D SU MO TU WE.
22 PM SET CURRENT DA TE / TIME PRO G RAM M I N G THE C O NTRO LLE R ................................................................................... Two key features of the ICC that make programming a snap are its clear, easy-to-read LCD display and its easy-to-use dial design.
23 SET WA TERING ST ART TIMES PM START TIME SET WA TERING ST ART TIMES PM START TIME SETTING WA TERING ST ART TIME 1. Turn the dial to the SET WATERING START TIMES position. 2. The factory preset is set on program A . If necessary you can select program B , C , or D by pressing the button.
24 PRO G RAM M I N G THE C O NTRO LLE R (continued) .............................................................. SET ST A TION RUN TIMES START TIME START TIME SETTING ST A TION RUN TIMES (Length of Watering for Each Area) 1. Turn the dial to the SET STATION RUN TIMES position.
25 INTERVAL DAYS REMAINING Selecting Interval Watering This feature is convenient if you want to have a more consistent watering schedule without having to worry about the day of the week or the date. The interval you select is the amount of days between watering.
26 PRO G RAM M I N G THE C O NTRO LLE R (continued) .............................................................. RUN RUN After programming is complete, turn the dial to RUN to enable automatic execution of all selected programs and start times. Watering will not occur unless dial is in the RUN position.
27 One T ouch Manual Start and Advance You can also activate all stations to water without using the dial. 1. Hold down the button for 2 seconds. 2. This feature automatically defaults to program A . You can select program B , C or D by pressing the program.
28 SET PUMP OPERA TION PUMP PUMP SYSTEM OFF There are four advanced features available to customize the ICC to more complex watering requirements. Two of these features are “ hidden ” to make accidentally programming them nearly impossible.
29 RUN CYCLE SET ST A TION RUN TIMES SOAK NOTE: The hidden features described below can only be entered by starting with the dial in the RUN position and holding down various buttons while the knob is turned to various setup positions. This makes it virtually impossible for someone to stumble onto these features.
30 SET ST A TION RUN TIMES RUN DELAY Setting the Soak Times It is only necessary to set a SOAK time if the accumulated CYCLE times on any single program will not provide an adequate soak time.
31 WHA T SIZE FIELD WIRING CONDUIT SHOULD I USE? Locate the size conduit across the top and the wire size along the side. Where the two intersect on the table tells you approximately how many wires will fill the conduit. Example: 49 wires of 18 AWG will fit in 1 1 / 2 " conduit.
32 TRO U B LES H O OTI NG G UI D E .................................................................................................. PROBLEM CAUSES SOLUTIONS There is no display . Check AC power wiring. Correct any errors. The display reads “ ERR ” .
33 PROBLEM CAUSES SOLUTIONS Rain sensor will not shut off system. Incorrect sensor type wired directly into Make sure sensor is microswitch type sensor cir cuit. such as Mini-Clik ® . The controller recognizes 48 stations Make sure AC power is connected.
34 S PEC IFI CA TI O N S ..................................................................................................................... Operating Specifications • Station Run Time: 1 minute to 2 hours (in 1-minute increments) on programs A, B, and C.
I N FOR MA TI ON AB O UT YOU R S PR I N K LER SYSTE M ....................................................... Date of Installation: ____________________________________________________________________.
FC C NOTI C E .............................................................................................................................. This controller generates radio frequency energy and may cause interference to radio and television reception.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hunter Fan ICC-801PL è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hunter Fan ICC-801PL - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hunter Fan ICC-801PL imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hunter Fan ICC-801PL ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hunter Fan ICC-801PL, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hunter Fan ICC-801PL.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hunter Fan ICC-801PL. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hunter Fan ICC-801PL insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.