HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guide (formerly Smart Array Cluster Sto.
HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM © 2002, 2003 Hewlett-Packard De velopment Company, L.P. Microsoft®, Windows®, and Windows NT® are trademarks of Microsoft Corporation in the U.S. and other countries.
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide iii HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM Contents About This Guide Audience Assumptions ................................
Contents iv HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM Chapter 4 Component Identification Front Panel Components ..............
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide v HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM About This Guide This maintenance and service guide can be used for reference when servicing the HP StorageWorks Modular Smart Array 500 system.
About This Guide vi HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM CAUTION: To properly ventilate the system, you must provide at least 7.
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 1-1 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:55 AM 1 Illustrated Parts Catalog .
Illustrated Parts Catalog 1-2 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:55 AM Ta.
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-1 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM 2 Removal and Replacement Pr.
Removal and Replacement Proced ures 2-2 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 1.
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-3 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM WARNING: Be sure that the AC power supply branch circuit that provides power to the rack is not overloaded.
Removal and Replacement Proced ures 2-4 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 1.
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-5 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Hot-Plug SCSI Hard Drive CAUTION: If you must replace a hot-plug drive, follo w the guide lines in this section.
Removal and Replacement Proced ures 2-6 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM To remove the component: 1. Be sure that the online and activity LEDs on the failed drive are both off.
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-7 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 1.
Removal and Replacement Proced ures 2-8 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Bezel Blank To remove the component: CAUTION: Always populate bays with either a compon ent or bla nk.
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-9 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 1.
Removal and Replacement Proced ures 2-10 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Battery-Backed Cache Module CAUTION: To prevent data loss or equipment dam age, follow the instruct ions in this procedure.
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-11 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Blower To remove the component: WARNING: The blower blades rotate at a high speed.
Removal and Replacement Proced ures 2-12 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 .
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-13 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM To remove the component: 1. Disconnect the power cord from the power supply.
Removal and Replacement Proced ures 2-14 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM 2-Port and 4-Port Shared Storage Modules To remove the component: 1.
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-15 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Interconnect Blank To remove the component: CAUTION: Always populate interconnect bays with a blank.
Removal and Replacement Proced ures 2-16 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Power Button/LED Assembly To remove the component: 1.
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-17 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 .
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 3-1 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:59 AM 3 Diagnostic Tools Server Utilities HP utilities provide reporting functions that enable event-focused management and diagnostics.
Diagnostic Tools 3-2 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:59 AM ROM Upgrades Each MSA500 controller has a ROM that contains the controller firmware.
Diagnostic Tools HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 3-3 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:59 AM NetWare Onl.
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-1 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM 4 Component Identification F.
Component Identification 4-2 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Enc.
Component Identification HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-3 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Rea.
Component Identification 4-4 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM 2-P.
Component Identification HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-5 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM 2-P.
Component Identification 4-6 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM 4-P.
Component Identification HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-7 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM 4-P.
Component Identification 4-8 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Controller Components Controller Display Each MSA500 controller has an LCD displa y for informational and error messages.
Component Identification HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-9 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Con.
Component Identification 4-10 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Ta.
Component Identification HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-11 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM SC.
Component Identification 4-12 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Ho.
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 5-1 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:04 AM 5 Specifications System Unit Specification Table 5-1: System Unit Specifications Specification Value Dimensions Height 17.
Specifications 5-2 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:04 AM Table 5-1: Sy.
Specifications HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 5-3 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:04 AM Hot-Plug AC Power Supply Table 5-4: Hot-Plug Po wer Supply Specifications Specification Value Height 12.
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide Index-1 COMPAQ CONFIDE NTIAL Codename: Aurora Part Number: 2518 50-004 Last Saved On: 9/19/03 11:03 AM Index Symbols and N.
Index Index-2 HP StorageWorks Modular Smart Array 500 System Maintenance an d Service Guide COMPAQ CONFIDE NTIAL Codename: Aurora Part Number: 2518 50-004 Last Saved On: 9/19/03 11:03 AM drives See h .
Index HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide Index-3 COMPAQ CONFIDE NTIAL Codename: Aurora Part Number: 2518 50-004 Last Saved On: 9/19/03 11:03 AM backplane 2-1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.