Manuale d’uso / di manutenzione del prodotto SRH/3 KM-2100SWH3 del fabbricante Hoshizaki
Vai alla pagina of 101
Hoshizaki “A Superior Degr ee of Reliability” www .hoshizaki.com Models KM-1301SAH/3, SWH/3, SRH/3 KM-1400SWH-M, SWH3-M KM-1601SAH/3, SWH/3, SRH/3 KM-1900SAH/3, SWH/3, SRH/3 KM-2100SWH3, SRH3 KM-2500SWH3, SRH3 KMH-2000SWH/3, SRH/3 Stackable Crescent Cuber Hoshizaki America, Inc.
2 W ARNING Only quali ed ser vice technicians should inst all and ser vice the appliance . T o obtain the name and phone number of y our local Hoshizaki Cer ti ed Ser vice Repr esentativ e, visit www .hoshizaki.com. No ser vice should be under tak en until the technician has thor oughly r ead this Ser vice Manual.
3 CONTENTS Impor tant Saf et y Inf or mation ................................................................................................. 6 I. Construction and W ater/R efrigeration Cir cuit Diagr am ..............................................
4 C . Set tings and A djustments ............................................................................................ 45 1 . Def ault Dip Switch Set tings .................................................................................... 45 a) "E" and "G" Contr ol Board without Har v est P ump Timer Oper ation .
5 23. KM-1 900SRH with URC-21F ............................................................................... 82 24. KM-1 900SRH with URC-22F ............................................................................... 83 25. KM-1 900SRH3 with URC-21F .
6 Impor tant Safety Inf ormation Throughout this man ual, notices appear t o bring your at tention t o situations which could result in death, serious injur y , damage t o the appliance, or damage t o proper t y . W ARNING Indicates a hazar dous situation which could r esult in death or serious injury .
7 W ARNING, continued • The appliance is not intended f or use by per sons (including children) with r educed ph y sical, sensor y , or mental capabilities, or lac k of e xper ience and knowledge , unless they ha ve been giv en super vision or instr uction concerning use of the appliance by a per son responsib le f or their safety .
8 I. Construction and W ater/R efrigeration Cir cuit Diagram A. KM Construction 1 . Air-Cooled Models (SAH/3) Ev aporat or Assembl y Spra y T ubes Inlet W ater V alv e W ater Supply Inlet Hot Gas V al.
9 Ev aporat or Assembl y Spra y T ubes Inlet W ater V alv e W ater Supply Inlet Hot Gas V alv e Junction Bo x W ater Regulating Va l v e Check V alv es (refrigeration) Contr ol Bo x Liquid Line V alv .
10 Evapor at or Assembl y Spra y T ubes Inlet W ater V alv e W ater Supply Inlet Hot Gas V alv e Junction Bo xes Receiv er Check V alv es (refrigeration) Contr ol Bo x Liquid Line V alv e Drier T rans.
11 B. KMH Construction 1 . W ater -Cooled Models (SWH/3) Ev aporat or Assembl y Spra y T ubes Inlet W ater V alv e Float S witch W ater P ump W ater Supply Inlet Junction Bo x W ater Regulating V alv .
12 2. Remot e Models (SRH/3) Ev aporat or Assembl y Spra y T ubes Inlet W ater V alv e Float S witch W ater P ump W ater Supply Inlet Junction Bo x Check V alv es (refrigeration) Contr ol Bo x Liquid .
13 C. W at er/R efr igeration Cir cuit Diagr am 1 . Air-Cooled Models (SAH/3) W at er Supply Cleaning V alv e Float Switch Drain Check V alv e Thermostatic Expansion V alves Compr essor Hot Gas Va l v.
14 2. W at er -Cooled Models (SWH/3/-M) W at er Supply Cleaning V alv e Float Switch Drain Check V alv e Thermostatic Expansion V alves Compr essor Hot Gas Va l v e Check V alv es High-P ressure Switc.
15 3a. Remot e Models (SRH/3) Ex cept KM-250 0SRH3 Condenser Unit with Headmast er (CPR) W at er Supply Cleaning V alv e Float Switch Drain Check V alv e Expansion V alv es Compr essor Hot Gas Va l v .
16 3b. Remot e Models (SRH3) KM-250 0SRH3 Condenser Unit without Headmast er (CPR) W at er Supply Cleaning V alv e Float Switch Drain Check V alv e Expansion V alv es Compr essor Hot Gas Va l v e Chec.
17 II. Sequence of Operation and Service Diagnosis A. Sequence of Operation Flo w Char t 1 . "E" and "G" Control Boar d without Harvest P ump Timer Operation Components Energized w.
18 • WV time: 6 min. or the length of har vest min us 50 sec. (S4 dip switch 7), whiche ver is shor t er . Do not adjust S4 dip s witch 7 out of the f actory position.
19 B. Service Diagnosis W ARNING • The appliance should be diagnosed and repair ed only b y quali ed ser vice personnel t o reduce the risk of death, electr ic shoc k, serious injur y , or re .
20 1 . "E" and "G" Control Boar d without Harvest P ump Timer Diagnosis 3) P ow er On : T ur n on the power suppl y , then mov e the control s witch to the "ICE" position. A 5-sec. delay occur s. • "E" Contr ol Board: CB red "PO WER OK" LED tur ns on.
21 5) Initial Harvest Cy c le – LEDs 1, 4, and 2 are on. WV continues. Comp , FMR, and HGV energiz e. CB monitor s the warming of the ev aporat or via the ther mist or locat ed on the suction line. When the thermistor r eaches 48°F (9°C), CB reads 3.
22 b) Comp and FMR Diagnosis : If Comp and FMR de-energiz e once freeze begins , check that appliance has not shut of f on HPS ("POWER OK" LED of f). If so , chec k "3)b) HPS Diagnosis" abov e. If "POWER OK" LED is on, chec k for 1 1 5V AC at CB K1#1 (V) or #9 (V) to neutr al (W).
23 h) F r eeze T ermination Diagnosis: Af ter 5 min. in freeze , disconnect CB K5 FS connector . 1 5 sec. later appliance should s witch out of the freez e cy cle (1 5 second dela y af ter FS opens bef ore t er minating the freez e cy cle). If appliance remains in freez e longer than 1 5 sec.
24 8) Normal Harv est Cy c le – Same as the initial harvest c y cle. Return to st ep 5 abov e. Note: Appliance continues t o cy cle until BC is satis ed or power is turned of f .
25 2. "G" Control Boar d with Harvest P ump Timer Diagnosis 3) P ow er On : T ur n on the power suppl y , then mov e the control s witch to the "ICE" position. A 5-sec. delay occur s. CB red "PO WER OK" LED and gr een "BC CLOSED" LED turn on.
26 5a) Initial Harvest Cy c le – LEDs 1, 4, and 2 are on. WV and X1 1 r ela y continue . Comp , FMR, HGV , and X1 0 rela y energiz e . CBmonitor s the warming of the e v aporat or via the ther mist or locat ed on the suction line. When the thermistor r eaches 48°F (9°C), CB reads 3.
27 If 1 1 5V A C is present on t er minal #3(P) and not on t erminal #5 (Y), replace X1 0 rela y . If 1 1 5V A C is present on X1 0 rela y ter minal #7 (Y) and PM is not ener giz ed, check f or 1 1 5V A C at X1 0 rela y terminal #4 (R) to neutral (W) and t erminal #6 (DBU) to neutr al (W).
28 c) WV and HGV Diagnosis : If WV is ener gized, chec k for 1 15V A C at CB K1 #6 (O) t o neutral (W). If 1 1 5V A C is pr esent af ter PM ener giz es in har v est cy cle, r eplace CB. If 1 1 5V A C is not present, r eplace WV (bypassing). If HGV did not de-energiz e at the end of har v est, chec k f or 1 1 5V AC at CB K1 #2 (P) t o neutral (W).
29 7) Pump-Out Cy cle – LEDs 1, 3, and 2 are on (1 0/20 second pump-out). Timing of the rst pump-out is det er mined by S4 dip s witch 5& 6. See the tab le belo w . "G" Control Boar d Settings S4 Dip S witch Set ting Pump-Out F requency 1st Pump-Out "G" Control Boar d No.
30 8) Normal Harv est Cy c le – Same as the initial harvest c y cle. Return to st ep 5a) abov e. Note: Appliance continues t o cy cle until MBC is satis ed or power is s witched of f . The appliance alw ay s restar ts at the 1 -min. ll cy cle.
31 C. Control Boar d Check Bef or e r eplacing CB that does not sho w a visib le def ect and that y ou suspect is bad, alw ay s conduct the follo wing chec k pr ocedur e. This procedur e will help you v erify your diagnosis. Alar m R eset: If CB is in alar m (beeping), press the "ALARM RESET" b ut ton on CB while CB is beeping.
32 D . Bin Contr ol Check BC shuts down the icemak er within 1 0 sec. when ice contacts the ther mostatic b ulb , reg ardless of the cy cle at activation. NO TICE When the ambient t emperature is belo w 45°F (7°C), BC opens and shuts down the appliance e v en if the ice storage bin is empty .
33 E. Float S witch Chec k and Cleaning FS is used to det er mine that there is suf ficient w ater in the wat er tank af ter the 1 -min. ll c y cle and af ter each harvest cy cle. FS is also used to det er mine that the appr opriate v olume of wat er has been conv er ted int o ice befor e switching out of the fr eez e cy cle.
34 2. Float Switc h Cleaning Depending on local wat er conditions, scale ma y b uild up on FS . Scale on the switch can cause the oat t o stic k. In this case, FS should be cleaned. 1) T ur n of f the power suppl y . 2) Remo ve the fr ont panel, then mo v e the contr ol s witch to the "OFF" position.
35 F . Thermist or Check T o check thermistor r esistance , f ollow the steps belo w . 1) T ur n of f the power suppl y . 2) Remo ve the fr ont panel. Mov e the contr ol s witch to the "OFF" position. 3) Remo ve the contr ol bo x cov er . 4) Remo ve the thermistor fr om the r efrigerant tubing.
36 G. Diagnostic T ables 1 . No Ice Pr oduction No Ice Pr oduction - Possib le Cause 1. P ower Suppl y a) Of f, b lown fuse , or tripped break er . b) Not within specications. 2. Main T ransf ormer (3 phase model) a) V oltage tap s witch not set t o pr oper v oltage .
37 No Ice Pr oduction - Possib le Cause 15 . P ump Motor a) Motor winding open. b) Bearing wor n out or loc ked r otor . c) Def ectiv e capacitor . d) Mechanical seal worn out. 16 . Ther mostatic Expansion V alv e a) Bulb loose. b) Operating erraticall y .
38 F reeze-Up - P ossible Cause 12 . Hot Gas V alv e a) Closed or restricted. 13 . Liquid Line V alv e a) Open. F reeze Cyc le 1. Evapor at or a) Scaled up . b) D amaged. 2. Spra y T ubes and/or Spray Guides a) Dir ty . b) Out of position. 3. Refrigerant Charge a) L o w.
39 Low Ice P r oduction - P ossible Cause Long F reeze Cyc le 1. Evapor at or a) Scaled up , dir ty . 2. Float Switch See "II.E. Float Switch Chec k and Cleaning" a) Scaled up , dir ty . b) Float sticking . c) Def ectiv e s witch. 3. Inlet W ater V alv e a) Leaking by .
40 III. Controls and A djustments • A Hoshizaki e x clusive contr ol board is emplo yed in KM and KMH series appliances. • All models are pr etest ed and f actor y adjust ed. • F or a contr ol boar d chec k pr ocedur e, see "II.C . Control Boar d Check.
41 A. Control Boar d L a y out 1 . "E" Control Boar d "E" Control Boar d P ar t Number 2A1 41 0-02 "E" Contr ol Boar d Micropr ocessor (control boar d r e vision le vel i.
42 2. "G" Control Boar d "G" Control Boar d P ar t Number 2A3792-0 1 "G" Contr ol Boar d • K4 (red) Connect or Mechanical Bin Contr ol or K4 Jumper (thermostatic bin co.
43 B. LED Lights and A udible Alarm Saf eties 1 . "E" Control Boar d At star tup , a 5-second delay occur s while the control boar d conducts an int er nal timer check.
44 2. "G" Control Boar d At star tup , a 5-second delay occur s while the control boar d conducts an int er nal timer check. A beep occur s when the control s witch is mov ed to the "ICE" position. The red "PO WER OK" LED indicat es pr oper contr ol v oltage and r emains on unless a control v oltage pr oblem occur s.
45 C. Set tings and Adjustments NO TICE Dip s witches ar e f actor y set. F ailure t o maintain f actory set tings ma y adver sel y af fect perf or mance and warr anty cov erage .
46 F reeze Timer (9 & 1 0) P ump-Out Fr equency Control (5 & 6) P ump-Out Timer (3 & 4) Har v est Timer (1 & 2) F actory Use (8) Bin Contr ol Select or (7) "E" Contr ol Board.
47 3. Pump-Out Timer (S4 dip switc h 3 & 4) NO TICE On models with har v est pump timer , do not adjust 3 off and 4 on. P ump does not run in pump-out rotation in this set ting .
48 4. Pump-Out F requency Contr ol (S4 dip switch 5 & 6) The pump-out frequenc y contr ol is f actor y set. Generall y no adjustment is requir ed. How e ver , where wat er qualit y is bad and the icemaker needs a pump-out mor e of t en, the pump-out frequenc y can be adjust ed.
49 b) Harvest P ump Timer: "G" Contr ol Boar d NO TICE F actory set for pr oper operation. Do not adjust. Adjustment outside of the f actor y def ault set ting ma y r esult in damage t o the appliance. Depending on the har v est pump timer set ting, the pump mot or either sta ys of f or is energiz ed the last 50 seconds of har vest.
50 8. Float Switc h Select or (S5 dip switc h 1): "G" Control Boar d NO TICE Do not adjust. This must be lef t in the f actor y def ault position or the icemaker will not operat e corr ectl y . 9. Re ll Counter (S5 dip switch 2 thr ough 5): "G" Contr ol Boar d NO TICE Do not adjust.
51 IV . Refr igeration Cir cuit and Component Ser vice Inf or mation W ARNING • This appliance should be diagnosed and repair ed only b y quali ed ser vice personnel t o reduce the risk of death, electr ic shoc k, serious injur y , or re . • Mov e the control s witch to the "OFF" position and turn off the po wer supply .
52 2. Brazing W ARNING • R-404A itself is not ammab le at atmospheric pressur e and temperatur es up t o 1 7 6°F (80°C). • R-404A itself is not e xplosiv e or poisonous.
53 4) Close the low -side val v e and high-side val v e on the g auge manif old. 5) Disconnect the gauge manif old hose from the v acuum pump and at tach it t o a refrigerant service cylinder . Remember t o loosen the connection and purge the air fr om the hose.
54 B. Component Service Infor mation NO TICE When r eplacing a component listed belo w , see the notes t o help ensur e pr oper operation. Component Notes Compr essor 1 phase: Install a new st ar t capacitor , r un capacitor , and star t rela y . 3 phase: Install a new magnetic cont actor .
55 C. W at er R egulating V alve Adjustment (w ater -cooled models) The wat er regulating v al v e is f actor y set, and generall y no adjustment is requir ed. Howe ver , when necessar y , adjust the wat er regulator using the f ollowing pr ocedure. 1) P r epar e a ther momet er t o chec k the condenser drain t emperature .
56 V . Maintenance The maintenance schedule belo w is a guideline. More fr equent maintenance ma y be requir ed depending on wat er quality , the appliance's en vir onment, and local sanitation regulations W ARNING • Only quali ed ser vice technicians should service the appliance.
57 VI. Pr eparing the Icemak er f or Per iods of Non-Use NO TICE • When st oring the appliance f or an e xt ended time or in sub-fr eezing t emperatur es, f ollo w the instructions below t o pr e v ent damage.
58 3. On wat er -cooled model, remo v e the w ater fr om the wat er -cooled condenser: 1) Make sur e the power suppl y is off , then remo ve the fr ont, t op , and r ight side panels. 2) Close the condenser wat er supply line shut-of f val ve . If connected t o a closed loop sy stem, also close the condenser r eturn line shut-of f v al v e .
59 VII. Disposal The appliance contains r efrigerant and must be disposed of in accor dance with applicable national, st at e , and local codes and r egulations.
60 VIII. T echnical Infor mation W e r eser v e the r ight to mak e changes in specications and design without pr ior notice. A. Specication and P erf ormance Data P r essur e data is r ecor ded at 5 min. into fr eezing cycle . The data not in bold should be used f or r ef erence onl y .
61 2. KM-1 30 1SAH3 SPECIFICAT ION SHEET AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 9.5 A ( 5 Min. Fr eeze AT 104°F / W T 80°F) MINIMUM CIRCUI T AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTR IC & W ATER C ONSUMPT ION 90/70°F 70/50°F ELECTR IC W (kW H /100 lbs.
62 3. KM-1 30 1SWH SPECIFICAT ION SHEET AC SUPPLY VOLTAGE 208-230/60/1 (3 wi re with neutral f or 115V) AMPERAGE 8.2 A ( 5 Min. Fr eeze AT 104°F / W T 80°F) MINIMUM CIRCUIT AMP ACITY 20 A MAXIMUM FUSE SIZE 20 A 90/70°F 70/50°F ELECTR IC W (kW H/100 lbs.
63 4. KM-1 30 1SWH3 SPECIFICATION SHEET 208-230/60/3 6.1 A ( 5 Min. Freeze AT 104°F / WT 80°F) 20 A 20 A 90/70°F 70/50°F 1840(3.4) 1770(3.2) 248(19.
64 5. KM-1 30 1SRH with URC-14F SPECIFICATION SHEET AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) AMPERAGE 13.5A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.
65 6. KM-1 30 1SRH3 with URC-14F SPECIFICATION SHEET AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 10.7A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2140(4.3) 2090(3.
66 7 . KM-1 40 0SWH-M SPECIFICAT ION SHEET AC SUPPLY VOLTAGE 208-230/60/1 (2 W ire) AMPERAGE 9.7 A ( 5 Min. Freeze AT 104°F / W T 80°F) MINIMUM CIRCUIT AMPACITY 15 A MAXIMUM FUSE SIZE 15 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
67 8. KM-1 40 0SWH3-M SPECIFICAT ION SHEET AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 7.1 A ( 5 Min. Freeze AT 104°F / W T 80°F) MINIMUM CIRCUIT AMPACIT Y 15 A MAXIMUM FUSE SIZE 15 A ELECTRIC & W AT ER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
68 9. KM-1 60 1SAH SPECIFICATION SHEE T AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) AMPERAGE 15.0 A (5 Min. Freeze AT 104°F/WT 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.
69 1 0. KM-1 60 1SAH3 SPECIFICATION SHEET AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 12.0 A (5 Min. Freeze AT 104°F/ W T 80°F) MINIMUM CIRCUIT AMPACIT Y 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
70 1 1 . KM-1 60 1SWH SPECIFICATION SHEET AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) AMPERAGE 13.4 A (5 Min. Freeze AT 104°F/ W T 80°F ) MINIMUM CIRCUIT AMPACIT Y 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W AT ER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
71 1 2. KM-1 60 1SWH3 SPECIFICATION SHEET AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 9.0 A (5 Min. Freeze AT 104°F/ W T 80°F) MINIMUM CIRCUIT AMPACIT Y 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
72 1 3. KM-1 60 1SRH with URC-21F Auxiliary Codes: R-0, R-1, and some S-1 This data applies t o units with an 8 l/min w at er v al v e . The 8 l/min water v alv e is par t number 3U0 1 1 1 -02 and has J248-032 stamped on the side of the val ve f acing the rear of the unit.
73 1 4. KM-1 60 1SRH with URC-21F Auxiliary Codes: some S-1 and S-2 and L ater This data applies t o units with a 1 5 l/min or 1 1 l/min water v alv e. The 1 5 l/min wat er v al v e is par t number 3U0 1 1 1 -0 1 and has J248-030 stamped on the side of the val ve f acing the r ear of the unit.
74 1 5. KM-1 60 1SRH with URC-22F Auxiliary Codes: S-2 and L ater This data applies t o units with an 1 1 l/min wat er v alv e. The 1 1 l/min water v alv e is either par t number 4A1 1 7 6-04 or 4A5251 -04 and has the par t number stamped on the side of the v al v e f acing the front of the unit.
75 1 6. KM-1 60 1SRH3 with URC-21F Auxiliary Codes: R-0, R-1, and some S-1 This data applies t o units with an 8 l/min w at er v al v e . The 8 l/min water v alv e is par t number 3U0 1 1 1 -02 and has J248-032 stamped on the side of the val ve f acing the rear of the unit.
76 1 7 . KM-1 60 1SRH3 with URC-21F Auxiliary Codes: some S-1 and S-2 and L ater This data applies t o units with a 1 5 l/min or 1 1 l/min water v alv e. The 1 5 l/min wat er v al v e is par t number 3U0 1 1 1 -0 1 and has J248-030 stamped on the side of the val ve f acing the r ear of the unit.
77 1 8. KM-1 60 1SRH3 with URC-22F Auxiliary Codes: S-2 and L ater This data applies t o units with an 1 1 l/min wat er v alv e. The 1 1 l/min water v alv e is either par t number 4A1 1 7 6-04 or 4A5251 -04 and has the par t number stamped on the side of the v al v e f acing the front of the unit.
78 1 9. KM-1 90 0SAH SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/1 (3 wire with neutral 115V) AMPERAGE 14.4 A (5 Min. Freeze AT 104°F / W T 80°F) MINIMUM CIRCUIT AMPACITY 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
79 20. KM-1 90 0SAH3 SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/3 AMPERAGE 8.59 A (5 Min. Freeze AT 104°F/W T 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W AT ER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
80 21 . KM-190 0SWH SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/1 (3 wire wi th neutral 115V) AMPERAGE 12.5 A (5 Min. Freeze AT 104°F/W T 80°F) MINIMUM CIRCUIT AMPACITY 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & W AT ER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
81 22. KM-1 90 0SWH3 SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/3 AMPERAGE 8.4 A (5 Min. Freeze AT 104°F/ W T 80°F) MINIMUM CIRCUIT AMPACIT Y 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
82 23. KM-1 90 0SRH with URC-21F SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/1 (3 wire with neutral 115V) AMPERAGE 14.9 A (5 Min. Freeze AT 104°F/ W T 80°F) MINIMUM CIRCUIT AMPACIT Y 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
83 24. KM-1 90 0SRH with URC-22F SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/1 (3 wire with neutral 115V) AMPERAGE 14.9 A (5 Min. Freeze AT 104°F/ W T 80°F) MINIMUM CIRCUIT AMPACIT Y 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
84 25. KM-1 90 0SRH3 with URC-21F SPECIFICATION SHEET AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 11.0 A ( 5 Min. Freeze AT 104°F / W T 80°F) MINIMUM CIRCUIT AMPACIT Y 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
85 26. KM-1 90 0SRH3 with URC-22F SPECIFICATION SHEET AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 11.0 A (5 Min. Freeze AT 104°F/W T 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
86 27 . KM-21 0 0SWH3 SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/3 AMPERAGE 10.5 A (5 Min. Freeze AT 104°F/W T 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W AT ER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
87 28. KM-21 0 0SRH3 with URC-22F SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/3 AMPERAGE 12.5 A (5 Min. Freeze AT 104°F/W T 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
88 29. KM-250 0SWH3 SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/3 AMPERAGE 14.2 A ( 5 Min. Freeze AT 104°F/W T 80°F) MINIMUM CIRCUIT AMPACITY 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
89 30. KM-250 0SRH3 with URC-23F SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/3 AMPERAGE 17.7 A ( 5 Min. Freeze AT 104°F/W T 80°F) MINIMUM CIRCUIT AMPACITY 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
90 31 . KMH-20 0 0SWH SPECIFICATION SHEET AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral 115V) AMPERAGE 12.1 A (5 Min. F reeze AT 104°F/W T 80°F) MINIMUM CIRCUIT AMPACIT Y 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
91 32. KMH-20 0 0SWH3 SPECIFICATION SHEET AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 7.7 A (5 Min. F reeze AT 104°F/W T 80°F) MINIMUM CIRCUIT AMPACIT Y 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W AT ER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
92 33. KMH-20 0 0SRH with URC-22F SPECIFICATION SHEET AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral 115V) AMPERAGE 14.9 A (5 Min. Freeze AT 104°F/ W T 80°F) MINIMUM CIRCUIT AMPACIT Y 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & W ATER CO NSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
93 34. KMH-20 0 0SRH3 with URC-22F SPECIFICATION SHEET AC SUPPLY VOLTAGE 208- 230/60/3 AMPERAGE 9.9 A (5 Min. Freeze AT 104°F/W T 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & W AT ER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (k W H/100 lbs.
94 B. W iring Diagrams 1 . Diagrams without Harv est P ump Timer Rela ys ("E" and "G" Contr ol Boar ds) a) KM-1 60 1SWH, KM-1 60 1SRH, KM-1 90 0S_H, KMH-20 0 0S_H * Contr ol T ransf or mer Output 1 0.
95 b) KM-1 60 1SWH3, KM-1 60 1SRH3, KM-1 90 0S_H3, KM-21 0 0S_H3, KM-250 0S_H3, KMH-20 0 0S_H3 * Contr ol T ransf or mer Output 1 0.5V at 1 15V * High-P ressur e S witch W ater -Cooled Model Remote Mo.
96 A uxiliar y C ode T -0, U-0 * 2. Diagrams with Harv est P ump Timer Rela ys ("G" Contr ol Boar d) a) KM-1 30 1S_H A uxiliary Code T -0, U-0 * High-P ressur e S witch W ater -Cooled Model Air and Remote Models Cut-out 384± 22 PSIG 41 2± 22 PSIG Cut-in 284±22 PSIG 327±22 PSIG 0 0 Contr ol T ransf or mer Output 1 0.
97 b) KM-1 30 1S_H3 A uxiliary Code T -0, U-0 * * High-P ressur e S witch W ater -Cooled Model Air and Remote Models Cut-out 384± 22 PSIG 41 2± 22 PSIG Cut-in 284±22 PSIG 327±22 PSIG 0 0 Contr ol T ransf or mer Output 1 0.
98 c) KM-1 30 1S_H A uxiliary Code U-1 and Later and KM-1 60 1SAH * * High-P ressur e S witch W ater -Cooled Model Air and Remote Models Cut-out 384± 22 PSIG 41 2± 22 PSIG Cut-in 284±22 PSIG 327±22 PSIG 0 0 Contr ol T ransf or mer Output 1 0.
99 d) KM-1 30 1S_H3 A uxiliary Code U-1 and Later and KM-1 60 1SAH3 * * High-P ressur e S witch W ater -Cooled Model Air and Remote Models Cut-out 384± 22 PSIG 41 2± 22 PSIG Cut-in 284±22 PSIG 327±22 PSIG 0 0 Contr ol T ransf or mer Output 1 0.
10 0 e) KM-1 40 0SWH-M * * High-P ressur e S witch W ater -Cooled Model Cut-out 384± 22 PSIG Cut-in 284±22 PSIG 0 Contr ol T ransf or mer Output 1 0.
101 f) KM-1 40 0SWH3-M * * High-P ressur e S witch W ater -Cooled Model Cut-out 384± 22 PSIG Cut-in 284±22 PSIG 0 Contr ol T ransf or mer Output 1 0.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hoshizaki SRH/3 KM-2100SWH3 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hoshizaki SRH/3 KM-2100SWH3 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hoshizaki SRH/3 KM-2100SWH3 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hoshizaki SRH/3 KM-2100SWH3 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hoshizaki SRH/3 KM-2100SWH3, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hoshizaki SRH/3 KM-2100SWH3.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hoshizaki SRH/3 KM-2100SWH3. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hoshizaki SRH/3 KM-2100SWH3 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.