Manuale d’uso / di manutenzione del prodotto KM-630MRF del fabbricante Hoshizaki
Vai alla pagina of 61
73082 HOSHIZAKI MODULAR CRESCENT CUBER SER VICE MANU AL KM-630MAF KM-630MWF KM-630MRF MODEL MAR. 19, 1999 NO.: ISSUED: REVISED: DEC. 15, 2003.
2 IMPORT ANT Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service Manual.
3 • Please review this manual. It should be read carefully before the icemaker is serviced or maintenance operations performed. Only qualified service technicians should service and maintain the icemaker. This manual should be made available to the technician prior to service or maintenance.
4 V. REMOVAL AND REPLACEMENT OF COMPONENTS .......................................... 40 1. SERVICE FOR REFRIGERANT LINES ............................................................... 40 [a] REFRIGERANT RECOVERY .....................................
5 I. SPECIFICATIONS 1. KM-630MAF * We reserve the right to make changes in specifications and design without prior notice..
6 2. KM-630MWF * We reserve the right to make changes in specifications and design without prior notice..
7 3. KM-630MRF * We reserve the right to make changes in specifications and design without prior notice..
8 4. CONDENSER UNIT URC-6F 24" (610 mm.) 23-1/32" (585 mm.) 19-11/16" (500 mm.) 18-1/8" (460 mm.) 20-15/32" (520 mm.) 21-15/16" (557 mm.) 7/8" DIA. HOLE (23 mm. DIA.) 6-5/16" (160 mm.) 2-15/16" (75 mm.) 18-1/8" (460 mm.
9 Galvanized Steel 21-15/16" x 15-11/16" x 17-7/8" (557 x 398 x 453.8 mm.) R404A 1 lb. 14 oz. (850 g) Net 61 lbs. (28 kg) Shipping 68 lbs. (31 kg) One Shot Couplings (Aeroquip) Permanent Connection Air-cooled Condensing Pressure Regulator Min.
10 II. GENERAL INFORMA TION 1. CONSTR UCTION [a] KM-630MAF Water Supply Inlet Junction Box Condenser Fan Motor Strainer Compressor Drier Spray Tubes Control Box Control Switch Bin Control Expansion Va.
11 [b] KM-630MWF.
12 [c] KM-630MRF.
13 2. CONTROLLER BO ARD [a] SOLID-STATE CONTROL 1) A HOSHIZAKI exclusive solid-state control is employed in KM-630MAF, KM630MWF, and KM-630MRF Modular Crescent Cubers. 2) A Printed Circuit Board (hereafter called “Controller Board”) includes a stable and high quality control system.
14 2) Defrost Timer The defrost cycle starts when the Float Switch opens and completes the freeze cycle. But the Defrost Timer does not start counting until the Thermistor senses 48°F at the Evaporator outlet.
15 problem occurs. At startup a 5 second delay occurs while the board conducts an internal timer check. A short beep occurs when the power switch is turned ON or OFF. The green LED’s 1-4 represent the corresponding relays and energize and sequence 5 seconds from initial startup as follows: Sequence Step LED’s on Length: Min.
16 (Control Pr oducts HOS-001A Board) to the K1 connector. If there is a white wire, place the switch in the C position. If this switch is placed in the wrong position either the compressor contactor will remain ener- gized with the control switch OFF or the unit will not start.
17 [c] SEQUENCE 1st Cycle 1. Unit energized and Control Switch to “ICE” position. Water supply cycle starts. 2. After 1 minute, Defrost cycle starts. 3. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Valve opening is limited to 6 minutes.
18 2nd Cycle and after with pump drain IMPORTANT Freeze cycle time is limited to 60 minutes even if Float Switch does not open. 1. Float Switch opens and signals to complete freeze cycle. Drain timer starts counting. 2. Drain timer stops counting. Pump drain is completed 3.
19 IMPORTANT Freeze cycle time is limited to 60 minutes even if Float Switch does not open. 2nd Cycle and after with no pump drain 1. Float Switch opens and signals to complete freeze cycle. 2. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Valve opening is limited to 6 minutes.
20 DIP SWITCH NO. 1 2 3 4 5 6 7 8 9 10 KM-630MWF OFF OFF OFF OFF ON ON OFF OFF OFF OFF KM-630MAF, OFF OFF OFF OFF ON ON OFF OFF ON OFF KM-630MRF [d] CONTROLS AND ADJUSTMENTS The Dip Switch is factory-adjusted to the following positions: Switch Nos. 1 and 2: Used for adjustment of the Defrost Timer.
21 1) Defrost Control A thermistor (Semiconductor) is used for a defrost control sensor. The resistance var- ies depending on the Suction Line temperatures. The Thermistor detects the tempera- ture of the Evaporator outlet to start the Defrost Timer. No adjustment is required.
22 3) Drain Timer The Drain Timer is factory-adjusted, and no adjustment is required. SETTING TIME Dip Switch Dip Switch No. 3 No. 4 T1 T2 OFF OFF 10 seconds 150 seconds ON OFF 10 seconds 180 seconds .
23 6) Bin Control CA UTION When the ambient temperature is below 45°F, the Bin Control Thermostat operates to stop the icemaker even if the Ice Storage Bin is empty. When the Thermostat is set in the prohibited range, the icemaker operates continuously even if the Ice Storage Bin is filled with ice.
24 (iv) After Step (iii), de-energize the unit and confirm that the Defrost Timer is in the minimum position. Disconnect the resistor from the Controller Board, and ener- gize the unit. After the 1 minute water supply cycle, the defrost cycle starts. Re-connect a 1.
25 III. TECHNICAL INFORMA TION 1. WATER CIRCUIT AND REFRIGERANT CIRCUIT [a] KM-630MAF.
26 [b] KM-630MWF.
27 [c] KM-630MRF.
28 2. WIRING DIA GRAMS [a] KM-630MAF and KM-630MWF Note: Pressure Switch Cut-out 412 ± PSIG Cut-in 327 ± 21 PSIG 21 0.
29 [b] KM-630MRF U1GMA0179608 Note: Pressure Switch Cut-out 412 ± PSIG Cut-in 327 ± 21 PSIG 21 0.
30 * * 3. TIMING CHART Control Sw. in ICE Bin Thermo- stat ON Pressure Sw. ON Overheat Protect Reset Hi Temp Mid Temp Lo Temp Too Lo Temp Normal Too Hi Temp Lo Water Max. Min. 60 min 5 min Min. Max. Max. 2 min 6 min 6 min Max. 20 min Time Up (60 sec) If Float Sw.
31 To Freeze Cycle To Stand-by Cycle (When Control Sw. is turned OFF, Pressure Sw. is OFF, or Thermistor Temp. exceeds t1.) From Freeze Cycle Control Sw. in WASH Max. 20 min *1 The Pump Motor waits for 2 seconds before starting a drain cycle. See “II.
32 4. PERFORMANCE DATA [a] KM-630MAF Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.
33 [b] KM-630MWF Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. * We reserve the right to make changes in specifications and design without prior notice.
34 [c] KM-630MRF Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. * We reserve the right to make changes in specifications and design without prior notice.
35 PROBLEM POSSIBLE CAUSE REMEDY [1] The icemaker a) Power Supply 1. “OFF” position. 1. Move to “ON” position will not start 2. Loose connections. 2. Tighten 3. Bad contacts. 3. Check for continuity and replace. 4. Voltage too high. 4. Check and get recommended voltage.
36 PROBLEM POSSIBLE CAUSE REMEDY l) Controller Board 1. Defective 1. See “II.2[e] CHECKING CONTROLLER BOARD.” m) Interlock Switch 1. “OFF” position. 1. Move to “ON” position. (Cleaning Valve) 2. Bad contacts. 2. Check for continuity and replace.
37 PROBLEM POSSIBLE CAUSE REMEDY [5] No water a) Water Supply Line 1. Water pressure too low and 1. Check and get comes from water level in Water Tank recommended pressure. Spray Tubes. too low. Water Pump b) Water Solenoid 1. Dirty mesh filter or orifice 1.
38 3. LO W ICE PRODUCTION PROBLEM POSSIBLE CAUSE REMEDY [1] Freeze cycle a) Float Switch 1. Leads short-circuit or 1. Check and replace. time is too defective switch. long. 2. Float does not move freely. 2. Clean or replace. b) Water Solenoid 1. Diaphragm does not close.
39 PROBLEM POSSIBLE CAUSE REMEDY [1] Icemaker will a) Bin Control 1. Set too cold. 1. Adjust warmer. not stop when Thermostat 2. Defective. 2. Replace. bin is filled with ice. [2] Abnormal a) Pump Motor 1. Bearings worn out. 1. Replace. noise b) Fan Motor 1.
40 V. REMOVAL AND REPLACEMENT OF COMPONENTS IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after the equipment is serviced.
41 5) Disconnect the Vacuum Pump, and attach a Refrigerant Service Cylinder to the High- side line. Remember to loosen the connection, and purge the air from the Hose. See the Nameplate for the required refrigerant charge. Hoshizaki recommends only virgin refrigerant or reclaimed refrigerant which meets ARI Standard No.
42 3. REMO V AL AND REPLA CEMENT OF COMPRESSOR IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made.
43 15) Evacuate the system, and charge it with refrigerant. For air-cooled and water-cooled models, see the Nameplate for the required refrigerant charge. For remote air-cooled models, see the Charge Label in the machine compartment. 16) Connect the Terminals, and replace the Terminal Cover in its correct position.
44 KM9311 4. REMO V AL AND REPLA CEMENT OF DRIER IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply.
45 3) Recover the refrigerant and store it in an approved container. 4) Remove the insulation and the Expansion Valve Bulb on the suction line. 5) Remove the Expansion Valve Cover, and disconnect the Expansion Valve using brazing equipment. 6) Braze the new Expansion Valve, with nitrogen gas flowing at the pressure of 3-4 PSIG.
46 IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Remove the panels. 3) Recover the refrigerant and store it in an approved container.
47 7. REMO V AL AND REPLA CEMENT OF EV APORA T OR IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made. 1) Turn off the power supply.
48 8. REMO V AL AND REPLA CEMENT OF W A TER REGULA TING V AL VE - W A TER-COOLED MODEL ONL Y IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made.
49 9. ADJUSTMENT OF W A TER REGULA TING V AL VE - W A TER-COOLED MODEL ONL Y The Water Regulating Valve (also called “WATER REGULATOR”) is factory-adjusted. No adjustment is required under normal use. Adjust the Water Regulator, if necessary, using the following procedures.
50 10. REMO V AL AND REPLA CEMENT OF CONDENSING PRESSURE REGULA T OR (C.P .R.) - REMO TE AIR-COOLED MODEL ONL Y IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made.
51 11. REMO V AL AND REPLA CEMENT OF THERMIST OR CA UTION 1. Fragile, handle very carefully. 2. Always use a recommended sealant (High Thermal Conductive Type), Model KE4560RTV manufactured by SHINETSU SILICONE, Part Code 60Y000-11, or Part Code 4A0683-01 or equivalent.
52 Note: For models with the Liquid Bypass, the Thermistor should be located upstream from the Liquid Bypass outlet, and its end should be 4-3/4" or more away from the outlet. See Fig. 3. Min. 4-3/4" Liquid Bypass Flow 10) Secure the insulation using the Plastic Cable Ties.
53 6) Install the new Fan Motor, and replace the removed parts in the reverse order of which they were removed. 7) Replace the panels in their correct positions. 8) Replace the Junction Box Cover in its correct position (Remote Air-cooled model). 9) Turn on the power supply.
54 3) Remove the Base Cover. 4) Drain the Water Tank by removing one end of the Pump Tubing. 5) Replace the removed parts in their correct positions. 6) Disconnect the Pump Suction and Discharge Hoses. 7) Remove the screws and the Pump Motor Bracket. 8) Remove the closed end connectors from the Pump Motor leads.
55 VI. MAINTENANCE AND CLEANING INSTRUCTIONS IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment.
56 [2] Remove the water from the potable water supply line: 1) Remove the Front Panel. (Except water-cooled model) 2) Move the Control Switch, on the Control Box, to the “OFF” position. 3) Wait 3 minutes. 4) Close the Potable Water Supply Line Shut-off Valve and open the Potable Water Supply Line Drain Valve.
57 CLOSED POSITION OPEN POSITION 2. CLEANING IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. WARNING 1. HOSHIZAKI recommends cleaning this unit at least once a year.
58 [a] CLEANING PROCEDURE 1) Dilute 16 fl. oz. of the recommended cleaner Hoshizaki “Scale Away” or “LIME-A-WAY” (Economics Laboratory, Inc.) with 3 gal. of water. 2) Remove all ice from the Evaporator and the Storage Bin. Note: To remove cubes on the Evaporator, turn off the power supply and turn it on after 3 minutes.
59 19) Replace the Front Panel in its correct position. 20) Turn on the power supply to fill the Water Tank with water. 21) Turn off the power supply after 3 minutes. 22) Remove the Front Panel, and fully open the Cleaning Valve. 23) Move the Control Switch to the “Wash” position.
60 [b] SANITIZING PROCEDURE - Following Cleaning Procedure 1) Dilute a 5.25% Sodium Hypochlorite solution (chlorine bleach) with water (Add 1.5 fl. oz. of sanitizer to 3 gal. of water). 2) Remove the Insulation Panel, if it is in its usual position. 3) Pour the sanitizing solution into the Water Tank.
61 3. MAINTENANCE IMPORT ANT This icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker. 1) Stainless Steel Exterior To prevent corrosion, wipe the exterior occasionally with a clean and soft cloth.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hoshizaki KM-630MRF è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hoshizaki KM-630MRF - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hoshizaki KM-630MRF imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hoshizaki KM-630MRF ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hoshizaki KM-630MRF, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hoshizaki KM-630MRF.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hoshizaki KM-630MRF. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hoshizaki KM-630MRF insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.