Manuale d’uso / di manutenzione del prodotto MS5145 Eclipse del fabbricante Honeywell
Vai alla pagina of 52
METROLOGIC INSTRUMENTS, INC. MS5100 Eclipse ™ Series Installation and User’s Guide.
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or b y any means without prior written consent, except b y reviewer, who may quote brief passages in a review, or provided for in the Cop yright Act of 1976.
ii T ABLE OF C ONTENTS Introducti on........................................................................................................... 1 Scanner and A ccessori es ...............................................................................
iii T ABLE OF C ONTENTS Regulatory Compliance Safety ............................................................................................................. 37 EMC .................................................................................
1 I NTRODUCTION The MS5145 Eclipse ™ is a single-line, h and-held laser scanner. Equipped with Metrologic’s pa tented CodeGate ® technology, Eclipse can be used in a wide variety of applications. Cod eGate technology allo ws the user to easily target the desired bar c ode and co mplete the data transmission with a simple press of a button.
2 I NTRODUCTION Scanner and Accessories B AS IC K IT Part # Description MS5145 Eclipse Scanner 00-02544 x MetroSelect Single-Line Confi guration Guide * 70-79016 x MS5100 Eclipse Series Installation and User ’s Guide * * Available on the Metrologic website - www.
3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description 55-55000 x -3 RS232 PowerLink Cable with Built in Power Jack straight cord, long strain relief, black 55-55002 x -3 Ke.
4 I NTRODUCTION Scanner Components I TEM N O . D ESCRIPTION 1 Mode Select Button/CodeGate Button (see page 12) 2 Red LED (see page 14) 3 Green LED (see page 14) 4 Pin Hole for Cable Release (s ee page 6) 5 Red Output Window (Laser Aperture) 6 Speaker (see page 13) 7 10-Pin RJ45, Female Socket (see page 33) Figure 1.
5 I NTRODUCTION Caution and Serial Number Labels Figure 2. Label Location on the Botto m of the Scanner with Exa mple Caution To maintain compliance w ith applicable standard s, all circuits connected to the scanner mu st meet the requirements for SELV (S afety E xtr a L ow Voltage) according to EN/IEC 60 950-1.
6 Figure 5. I NTRODUCTION Cable Removal Disconnect the power supply from the Po werLink cable and turn off power to the host system before removing the cable from the scanner. 1. Locate the small ‘pin -hole’ on the front side of the scanner near the end of the handle.
7 I NSTALLATION RS232, Light Pen or Laser Emulation 1. Turn off the host system. 2. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. 3. Connect the 9-Pin female end of the PowerLink cable to the appropriate communication port on the host device.
8 I NSTALLATION RS485 S 1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS5145. 3. Connect the other end of the MVC cable to Port 9 of the host device. 4. Turn on the host device See page 5.
9 I NSTALLATION Keyboard Wedge 1. Turn off the host system. 2. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. 3. Disconnect the keyboard from the host/PC. 4. Connect the Y ends of the PowerLink cable to the keyboard an d the host’s keyboard port.
10 I NSTALLATION Stand-Alone Keyboard 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the Eclipse. There will be a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5.
11 Figure 10. USB I NSTALLATION USB : Low Speed USB (-38) Full Speed USB (-40) 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector of the USB cable into the jack on the Eclipse. There will be a ‘click’ when the connection is made.
12 S CANNER O PERATION How to Use CodeGate and the Manual Activation Mode C ODE G ATE ® M ANUAL A CTIVATION M ODE * * This feature is not a default setting. Refer to the MetroSelect Configuration Guide for instructions on enabling the Manual Activation Mode.
13 S CANNER O PERATION Indicators Audible When the MS5145 scanner is oper ational, the scanner provides audi ble feedback to indicate the status of the scanner and the last scan. Eight settings are available for the tone of the beep (norma l, six alternate tones and no tone).
14 S CANNER O PERATION Indicators Visual The MS5145 is equippe d with a red LED and green LED which indicate the scanner’s state and the status of the current scan wh en the unit is in operation.
15 S CANNER O PERATION Indicators Failure One Razzberry Tone – On Power Up This indicates the scanner has experi enced a laser or flipper subsystem failure.
16 S CANNER O PERATION Depth of Field vs. Minimum Bar Code Element Width Minimum Bar Code Element Width A B C D E F mm .10 .12 .17 .26 .33 .66 mils 4.1 4.
17 S CANNER O PERATION Configuration Modes The MS5145 Eclipse has three modes of configur ation. • Bar Codes The Eclipse can be configured b y scanning the bar codes located in the MetroSelect ® Single-Line Conf iguration Guide ( MLPN 00-0254 4). This manual can be downloaded F REE at www.
18 S CANNER O PERATION 4. During configuration, the motor and laser turn off. YOU CANNOT SCAN A BAR CODE WHILE IN SERIAL CONFIGURATION MODE. 5. There is a 20 second window bet ween commands. If a 20 second timeout occurs, the scanner will send a [nak] and yo u must start over.
19 S CANNER O PERATION EXAMPLE #3 : The following example sho ws the events that occur when an invalid bar cod e is sent. This sample will load the factory default settings an d then set the baud rate to 19200.
20 T ROUBLESHOOTING G UIDE The following guide is for reference purpos es only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-43 6-3876 to preserve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces No power is being supplied to the unit.
21 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit powers up, but does not scan and/or beep. The unit is trying to scan a particular symbology that is not enabled. UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled b y default.
22 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit scans but the data is not correct. The unit’s configuration is not correct. Make sure that the proper PC type AT, PS2 or XT is selected. Verify the correct country code and data format is selected.
23 RS232 D EMONSTRATION P ROGRAM If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test t hat the communication port and scanner are work ing.
24 D ESIGN S PECIFICATIONS MS5145 Eclipse O PERATIONA L Light Source: V isible L aser D iode (V LD) @ 650 nm Laser Power: Less than 1.0 mW average Depth of Scan Field: 0 mm – 140 mm (0 " – 5.5") 0.33 mm (13 mil) Bar Code Scan Speed: 72 ± 2 scan lines per second Scan Pattern: Single scan line Minimum Bar Width: 0.
25 D ESIGN S PECIFICATIONS MS5145 Eclipse E LECTRICAL Input Voltage: 5VDC ± 0.25V Power: Operating 675 mW Current: Operating 135 mA average @ 5VDC DC Transformers: Class II; 5.
26 A PPLICATIONS AND P ROTOCOLS The model number on each scann er incl udes the scanner number and fa ctory default communications protocol. Scanner Version Identifier Communication Protoc ol(s) 00 La.
27 D EFAULT S ETTINGS Many functions of the scanner can be configu red or enabled/disab led . The scanner is shipped from the factor y c onfigured to a set of default conditions. All default parameters of t he scanner have an asterisk ( * ) marked in the default column.
28 D EFAULT S ETTINGS Parameter Default RS232 Light Pen RS485 S KBW USB Laser Emulation ITF Symbol Lengths Variable Minimum Symbol Length 3 Symbol Lengt.
29 D EFAULT S ETTINGS Parameter Default RS232 Light Pen RS485 S KBW USB Laser Emulation Infinite Same Symbol Timeout Inter-Character D elay Configurable In 1 m sec steps (max 2.
30 D EFAULT S ETTINGS Parameter Default RS232 Light Pen RS485 S KBW USB Laser Emulation Transmit Sanyo ID Characters Nixdorf ID LRC Enabled UPC Prefix UPC Suffix .
31 D EFAULT S ETTINGS Parameter Default RS232 Light Pen RS485 S KBW USB Laser Emulation 100 msec to Find Supplement Configurable in 100 mse c Steps (max 800 msec) * Coupon Code.
32 U PGRADING THE F LASH ROM F IRMWARE The MS5145 is part of Metrologic's line of scanners with flash upgrade able firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and Metrologic's MetroSet 2 software .
33 S CANNER AND C ABLE T ERMIN ATIONS Scanner Pinout Connections The MS5145 scanner interfaces terminate to a 10-pin modular jack. The serial number label i ndicates the interface enable d when the scanner is shipped from the factory.
34 S CANNER AND C ABLE T ERMIN ATIONS Figure 16. MS5145-00 Laser Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 Flip Sense/Start of Scan Output 5 Proximity Detect/ Tri.
35 S CANNER AND C ABLE T ERMIN ATIONS Cable Connector Configurations RS232 PowerLink Cable, 55-55000 x -3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light P.
36 S CANNER AND C ABLE T ERMIN ATIONS Cable Connector Configuration Keyboard Wedge Po werLink Cable 55-55002A-3 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 Volts DC .
37 R EGULATORY C OMPLIAN CE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adj ustments or perfo rmance of proced ures other than tho se specified herein may res ult in hazardous lase r light ex posure.
38 R EGULATORY C OMPLIAN CE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity pe rformance is not guarant eed for scan ner cables gr eater than 3 me ters in length when fully ex tended.
39 R EGULATORY C OMPLIAN CE EMC Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment.
40 L IMITED W ARRANTY The MS5145 Eclipse ™ scanner s are manufactured by Metrologic at its S uzhou, China facility. The MS5145 Eclipse scanners have a three (3) year limited warranty from the date of manufacture.
41 P ATENTS This METROLOGIC product may be covered by, but is not limited to, one or more of the following U.S. Patents: U.S. Patent No.; 5,216,232; 5,260,553; 5,340, 971; 5,424,525; 5,484,992; 5,525,.
42 I NDEX A AC .................................. see power accessories ............................... 2, 3 aperture ......................................... 4 B beeper ......................... see indicator button .................................
43 I NDEX S safety ..................................... 37, 39 stand ............................................. 3 Stand-Alone Keyboard see interfac e T terminatio ns ........................... 33–36 tone ........................................
44.
.
.
.
August 2008 70 - 79016 D.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Honeywell MS5145 Eclipse è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Honeywell MS5145 Eclipse - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Honeywell MS5145 Eclipse imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Honeywell MS5145 Eclipse ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Honeywell MS5145 Eclipse, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Honeywell MS5145 Eclipse.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Honeywell MS5145 Eclipse. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Honeywell MS5145 Eclipse insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.