Model AD1684B Receiver Dual Channel General Purpose Receiver Installation Instructions This manual describes the installation and operating procedures for the AD1684B Dual Channel Receiver. The Receiver provides for the control of a Pan/Tilt drive and a motorized Lens for two separate cameras.
This software/firmware is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software is furnished to the purchaser under a license for use on a single system.
The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.
.
CONTENTS Page DESCRIPTION............................................................................... 1 FEA TURES ..................................................................................... 1 Pan/T ilt and Lens Control ...................
.
AD1684B DESCRIPTION DESCRIPTION The AD1684B Receiver is used with American Dynamics Matrix Switching Systems to control pan, tilt, zoom, focus, iris, and auxiliary functions at a camera site. This Receiver is classified as a dual channel type, since two independent control channels are supplied.
SETUP AD1684B SETUP Receiver Configuration Setup AD1684B Receivers may be configured as a two-channel Pan/Tilt and Lens control unit or a single channel unit with four auxiliaries. A two-position Berg jumper, labeled J5 (see Figure 1), is provided to establish this configuration.
Camera Number Setting There are two DIP switches which associate the camera number with the respective channel, A or B. DIP switch S1 is for Pan/Tilt and lens control of Channel A, and DIP switch S2 is for Pan/Tilt and lens or auxiliary control of Channel B.
SETUP AD1684B 4 Table 4 - S2 Pan/Tilt and Lens Camera Number Switch Settings or Auxiliary Settings Channel B L = left ("off"); R = right ("on") CAMERA SWITCH CAMERA SWITCH NUMBER 1.
AD1684B INSTALLATION INSTALLATION This installation should be made by qualified service personnel and should conform to all local codes. Safeguards must be taken to avoid unintentional operation by employees and maintenance personnel working about the premises, by falling objects, by customers, by building vibration, and by similar causes.
CONNECTIONS AD1684B CONNECTIONS Code Line Connections The Code Line connection to the Receiver is made with user- supplied, shielded 2-wire twisted pair, Belden 8760 or equivalent (for Plenum use Belden 88760 or equivalent). The maximum code line length is 5000 feet.
AD1684B CONNECTIONS Pan/Tilt and Lens Connections The Receiver connection to a Pan/Tilt and a motorized Lens is with a 10-pin connector. This connector is located on the left side of the PCB and is labeled J7 (see Figure 1, page 2).
CONNECTIONS AD1684B Table 5 - Dual Pan/Tilt and Lens 10-pin Connector Pinout Channel A - J7 PIN No. FUNCTION Pan/Tilt PINOUT LENS PINOUT 01 Focus __________________ __________________ 02 Zoom ________.
AD1684B CONNECTIONS Auxiliary Connections The Receiver connection of auxiliary equipment is with a ten (10) pin connector, labeled J6, located on the right side of the PCB (see Figure 1, page 2).
CONNECTIONS AD1684B Pre-position (Preset) Connections The Receiver connection to a Pan/Tilt or Lens unit with pre- position servos is with a ten (10) pin connector labeled J4 (see Figure 1, page 2). For dual-channel operation a second 10-pin connector labeled J3 is used for channel B.
AD1684B CONNECTIONS Table 7 - Pre-position Pan/Tilt and Lens 10-pin Connector Pinout Channel A - J4 PIN No. FUNCTION Pan/Tilt Servo PINOUT Lens Servo PINOUT 01 + REF __________________ _______________.
CONNECTIONS AD1684B Power Input Connections Refer to the instructions provided with the enclosure for suitable conduit connectors (when required), and mounting and caution information. Two PG-16 liquid-tight bushings are supplied for use with cord diameters from .
TYPICAL SYSTEM CONNECTIONS.
.
TYPICAL SYSTEM CONNECTIONS AD2150 Controller to AD1684B MAXIMUM DISTANCE between AD1684B and AD2150 is 5000 Ft, using shielded, 18 AWG cable AD2150 AD1684B BWS RS232 PORTS 123 KEYBOARDS 2345 CAMERAS A.
TYPICAL SYSTEM CONNECTIONS AD1996 Controller to AD2091 Code Generator, to AD1684B AD1684B AD2091 AD1996 ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF B W S B W S B W S B W S B W S B W S B W .
TYPICAL SYSTEM CONNECTIONS AD1684B to AD1240P Pan/Tilt with Pre-position AD1684B 13-Pin Connector 1240P PAN/TILT 123456789 1 0 1 1 1 2 1 3 BLACK WHITE SHIELD FOCUS ZOOM IRIS DC GROUND AC COMMON DOWN UP DC GROUND RIGHT LEFT + REF PAN TILT FOCUS ZOOM - REF SHIELD SHIELD N.
.
INDEX.
.
Auxiliaries Configuration Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River, New York, 10965 Business: (914) 624-7600 Technical Support Center: 1-800-442-2225 .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il American Dynamics AD1684B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del American Dynamics AD1684B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso American Dynamics AD1684B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul American Dynamics AD1684B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il American Dynamics AD1684B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del American Dynamics AD1684B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il American Dynamics AD1684B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo American Dynamics AD1684B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.