INSTRUCTIONS–P ARTS LIST 306–646 Rev R Supersedes P This manual contains IMPORT ANT W ARNINGS AND INSTRUCTIONS READ AND RET AIN FOR REFERENCE GRACO INC.
306–646 SAFETY W ARNINGS HIGH PRESSURE FLUID CAN CAUSE SERIOUS INJUR Y . FOR PROFESSIONAL USE ONL Y. OBSER VE ALL W ARNINGS. Read And Understand All Instruction Manuals Before Operating Equipment.
3 306–646 EQUIPMENT MISUSE HAZARD General Safety Any misuse of the spray/dispensing equipment or accessories, such as overpressurizing, modifying parts, using incompatible chemicals and flu - ids, o.
4 306–646 INST ALLA TION E F H J K D L KEY A Air Supply Hose to Pump B Air Line Filter C Air Regulator and Gauge D Bleed–T ype Master Air V alve E Air Line Lubricator F Pump Runaway V alve G Bleed.
5 306–646 OPERA TION W ARNING Pressure Relief Procedure To reduce the risk of serious bodily injury , including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, al.
6 306–646 MAINTENANCE Shutdown and Care of the Pump Always follow the Pressure Relief Procedure W arning on page 7 whenever you shut of f the pump. Stop the pump at the bottom of its stroke to keep fluid from drying on the exposed displacement rod and damaging the throat packings.
7 306–646 TROUBLESHOOTING GUIDE Pressure Relief Procedure To reduce the risk of serious bodily injury , including fluid injec - tion, splashing in the eyes or on the skin, or injury from moving part.
8 306–646 DISPLACEMENT PUMP SERVICE Moving parts can pinch or amputate your fingers or other body parts. When the pump is operating, the priming piston (located at the pump intake) and the air motor piston (located behind the air motor shield) move.
9 306–646 9. Carefully guide the intake valve housing (28) up over the priming rod (32) and install it on the cylinder (39). Insert the four tie bolts (8) through the outlet housing (26) and engage the holes in the intake valve hous - ing. T orque the tie bolts oppositely and evenly to 60 ft–lb (82 N.
10 306–646 Model 222–638 Displacement Pump (Used on Models 222–526, 222–539, 223–984 and 223–991) NOTE: Before beginning, read “Before Y ou Start” on page 8. Disassembly NOTE: Refer to Fig 3 and the parts drawing during the following procedure.
11 306–646 Fig 3 53 45 42 SEE DET AIL A 34 SEE DET AIL B 38 SEE DET AIL C 3 30 6 36 37 28 31 11 28 *27 29 7 21 41 8 TORQUE T O 60 ft–lb (82 N.m) 44 TORQUE T O 40–50 ft–lb (54–68 N.m) 50 52 26 62 59 61 27* 60 DISPLACEMENT PUMP 222–638 REF .
12 306–646 P ARTS DRA WING – ST ANDARD PUMPS LIPS OF V–P ACKINGS MUST F ACE UP 1 (MODEL 208–356 SHOWN) 52 TORQUE T O 40–50 ft–lb (54–68 N.m) 49 **41 50 45 *15 *17 39 27* 4 26 **21 18 **42 33 19 34 *35 38 20 27* 29 27* 7 **32 11 3 **30 28 31 36 37 6 LIPS OF V–P ACKINGS MUST F ACE DOWN 8 TORQUE T O 60 ft–lb (82 N.
13 306–646 P ARTS LIST – ST ANDARD PUMPS Model 222–248, Series A 20:1 Ratio King Pump with Standard Air Motor Includes items 1–66 Model 204–287, Series K 10:1 Ratio Bulldog Pump with Standard Air Motor Includes items 1–66 Model 215–873, Series B 10:1 Ratio Bulldog Pump with Quiet Air Motor Includes items 1–66 REF NO.
14 306–646 P ARTS DRA WING – SEVERE–DUTY PUMPS Model 222–539, Series A 20:1 Ratio King Pump with Standard Air Motor and Severe–Duty Displacement Pump Includes items 1–66 Model 223–991, S.
15 306–646 P ARTS LIST – SEVERE–DUTY PUMPS Model 222–539, Series A 20:1 Ratio King Pump with Standard Air Motor and Severe–Duty Displacement Pump Includes items 1–66 Model 223–991, Serie.
16 306–646 ACCESSORIES USE GENUINE GRACO P ARTS AND ACCESSORIES Must be purchased separately . GROUNDING CLAMP 103–538 GROUND WIRE 208–950 7.6 m (25 ft) long, 1.
17 306–646 ACCESSORIES USE GENUINE GRACO P ARTS AND ACCESSORIES Must be purchased separately . GRACO THROA T SEAL LIQUID Non–evaporating liquid for wet cup 206–995 1 quart (0.95 liter) 206–996 1 gallon (3.8 liter) FLUID DRAIN V AL VE 210–658 350 bar (5000 psi) MAXIMUM WORKING PRESSURE 3/8 npt(f) mbe; V iton seals 200 LITER (55 gal.
18 306–646 ACCESSORIES USE GENUINE GRACO P ARTS AND ACCESSORIES Must be purchased separately . HYDRA–MASTIC AUT OMA TIC AIRLESS SPRA Y GUN 206–660 3000 psi (210 bar) MAXIMUM WORKING PRESSURE Has a 0.180 in. (4.57 mm) fluid valve orifice and internal 3–pin safety dif fuser for spraying highly viscous, semi– solid fluids.
19 306–646 DIMENSIONS 54.75” (1391 mm) 19.625” (499 mm) ON DOWN STROKE 1–1/2” NPT(F) FLUID OUTLET OPTIONAL FLUID OUTLET 3/4 NPSM(F) AIR INLET 13.875” (352 mm) 21.25” (540 mm) 4.25” (108 mm) DIA. MOUNTING HOLE LA YOUT 1 1.25” (286 mm) DIA.
20 306–646 TECHNICAL DA TA Air Operating Range Bulldog Models 204–287, 215–873, 222–526, and 223–984 40–100 psi (3–7 bar) . . . . . . . . . . King Models 222–248, 222–539, and 223–991 40–90 psi (3–6 bar) . . . . . . . . . . . .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco 222526 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco 222526 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco 222526 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco 222526 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco 222526, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco 222526.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco 222526. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco 222526 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.