IT
Goodmans logo
Manuale d'uso ufficiale

Goodmans Air Conditioner (DSXC18)

24 pagine·635 KB·Climatizzatore·PDF·EN
Goodmans Air Conditioner (DSXC18)
Indice dei contenuti 8 sezioni DSXC18 Spec Sheet · Nomenclature · Product Specifications · Expanded Cooling Data · … MostraNascondi
Page 1 of the Goodmans Air Conditioner (DSXC18) user manual — Contents
Pagina 1 · clicca per ingrandire
Pagina 1

DSXC18 S plit S ystem A ir C onditioner

U p to 18 SEER

C ooling C apacity : 34,000 - 56,000 BTU/ h

Goodmans Air Conditioner (DSXC18) — DSXC18 S plit S ystem A ir C onditioner diagram (page 1)
Fig. 1 · DSXC18 S plit S ystem A ir C onditioner

Contents

Nomenclature 2 Product Specifications 3 Expanded Cooling Data 4 AHRI Ratings 16 Dimensions 22 Wiring Diagram 23 Accessories 24

  • Standard Features
  • R-410A chlorine-free refrigerant
  • Two-Stage Copeland® UltraTech™ scroll compressor
  • High-density foam compressor sound blanket
  • ComfortNet™ Communications System compatible
  • Expanded ComfortAlert™ diagnostics built in
  • Set-up capable with 2 low-voltage wires to outdoor unit
  • Diagnostic indicator lights and storage of 6 fault codes
  • Color-coded terminal strip for noncommunicating set-up
  • Highand low-pressure switches
  • Factory-installed filter drier
  • Coil and ambient temperature sensors
  • Two-speed, super-quiet condenser fan motor
  • Sweat connection service valves with easy access to gauge ports
  • AHRI Certified; ETL Listed
  • Cabinet Features
  • Amana® brand sound control top design
  • Wire fan discharge grille
  • Steel louver coil guard
  • Baked-on powder-paint finish with 500-hour salt-spray approval
  • Top and side maintenance access
  • Single-panel access to controls with space provided for field-installed accessories
  • When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

* Complete warranty details available from your local dealer or at www.goodmanmfg.com To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.

SS-DSXC18 www.goodmanmfg.com 11/13 Supersedes 9/13

Page 2 of the Goodmans Air Conditioner (DSXC18) user manual — D X 036
Pagina 2 · clicca per ingrandire
Pagina 2

N omenclature

D X 036

S

A 18

A

Brand Engineering * D Goodman® Brand Minor Revision

Product Category Engineering * S Split System Major Revision Unit Type Electrical X Condenser R-410A 1 208/230 V, 1 Phase, 60 Hz Z Heat Pump R-410A 2 220/240 V, 1 Phase, 50 Hz 3 208/230 V, 3 Phase, 60 Hz Communication Feature 4 460 V, 3 Phase, 60 Hz C ComfortNet 4-wire communications ready 5 380/415 V, 3 Phase, 50 Hz

Efficiency Nominal Capacity 16 16 SEER 3 Tons 060 5 Tons 18 18 SEER 4 Tons

* Neither used for order entry or inventory management.

5,6 · 7,8,9 · 048 036

Page 3 of the Goodmans Air Conditioner (DSXC18) user manual — S pecifications
Pagina 3 · clicca per ingrandire
Pagina 3

S pecifications

DSXC18 0361ADSXC18 0481ADSXC18 0601A Cooling Capacity Nominal Cooling (BTU/h) Decibels35,000 7147,000 7257,000 74 Compressor RLA LRA15.3 8321.2 10427.1 152.9 Condenser Fan Motor Horsepower (RPM) FLA⅓ 2.80⅓ 2.80⅓ 2.80 Refrigeration System Refrigerant Line Size¹ Liquid Line Size (“O.D.) Suction Line Size (“O.D.) Refrigerant Connection Size Liquid Valve Size (“O.D.) Suction Valve Size (“O.D.) Valve Connection Type Refrigerant Charge Expansion Device Superheat at Service Valve Subcooling at Service Valve⅜" ⅞" ⅜" ⅞" Sweat 184 TXV 7-9°F 5-7°F⅜" 1⅛" ⅜" ⅞" Sweat 259 TXV 7-9°F 5-7°F⅜" 1⅛" ⅜" ⅞" Sweat 259 TXV 7-9°F 5-7°F Electrical Data Voltage-Phase-Hz Minimum Circuit Ampacity ¹ Max. Overcurrent Protection ² Min / Max Volts Electrical Conduit Size208/230-1-60 21.9 35 197 / 253 ½" or ¾"208/230-1-60 29.3 50 197 / 253 ½" or ¾"208/230-1-60 36.7 60 197 / 253 ½" or ¾" Equipment Weight (lbs) Ship Weight (lbs)250 272305 327316 338
Goodmans Air Conditioner (DSXC18) — S pecifications diagram (page 3)
Fig. 2 · S pecifications

¹ Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

  • Notes
  • Always check the S&R plate for electrical data on the unit being installed.
  • Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
  • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
  • Installation of these units that require a TXV Kit to be installed on the indoor coil.
  • PLEASE NOTE: the specified TXV is determined by the outdoor unit, not the indoor coil.
Page 4 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 4 · clicca per ingrandire
Pagina 4

Expanded Cooling Data – DSXC180361A* / CA*F4961*6**+TXV / MBVC2000**-1 Low Stage

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

MBh 25.3 26.2 28.8 - 24.7 25.6 28.1 - 24.1 25.0 27.4 - 23.6 24.4 26.8 - 22.4 23.2 25.4 - 20.7 21.5 23.5 -

S/T 0.76 0.63 0.44 - 0.79 0.66 0.45 - 0.81 0.67 0.47 - 0.83 0.70 0.48 - 0.86 0.72 0.50 - 0.87 0.73 0.50 -

∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 15 12 -

kW 1.30 1.33 1.38 - 1.41 1.45 1.50 - 1.51 1.55 1.60 - 1.60 1.63 1.69 - 1.67 1.71 1.77 - 1.73 1.77 1.84 -

Amps 5.3 5.5 5.7 - 5.8 5.9 6.1 - 6.3 6.5 6.7 - 6.7 6.9 7.1 - 7.2 7.4 7.6 - 7.6 7.8 8.1 -

HI PR 210 226 229 - 237 255 259 - 270 290 295 - 308 331 335 - 332 357 362 - 394 423 429 -

Lo PR 124 128 140 - 128 132 144 - 132 136 149 - 135 140 153 - 138 143 156 - 142 146 159 -

MBh 24.6 25.5 27.9 - 24.0 24.9 27.3 - 23.4 24.3 26.6 - 22.9 23.7 26.0 - 21.7 22.5 24.7 - 20.1 20.9 22.9 -

S/T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 -

∆T 20 17 13 - 20 17 13 - 20 17 13 - 20 18 13 - 20 17 13 - 19 16 12 -

kW 1.29 1.32 1.37 - 1.40 1.43 1.48 - 1.50 1.53 1.59 - 1.58 1.62 1.68 - 1.65 1.69 1.75 - 1.72 1.76 1.82 -

Amps 5.3 5.4 5.6 - 5.7 5.9 6.1 - 6.2 6.4 6.6 - 6.7 6.8 7.1 - 7.1 7.3 7.5 - 7.6 7.7 8.0 -

HI PR 208 224 227 - 235 253 256 - 267 288 292 - 305 327 332 - 329 354 359 - 390 419 425 -

Lo PR 123 127 138 - 126 130 142 - 131 135 147 - 134 138 151 - 137 141 154 - 140 145 158 -

MBh 22.7 23.5 25.8 - 22.2 23.0 25.2 - 21.6 22.4 24.6 - 21.1 21.9 24.0 - 20.1 20.8 22.8 - 18.6 19.3 21.1 -

S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.67 0.46 -

∆T 20 18 13 - 20 18 13 - 20 18 13 - 21 18 14 - 20 18 13 - 19 16 12 -

kW 1.28 1.31 1.36 - 1.39 1.42 1.47 - 1.48 1.52 1.57 - 1.57 1.60 1.66 - 1.64 1.68 1.74 - 1.70 1.74 1.80 -

Amps 5.2 5.4 5.5 - 5.7 5.8 6.0 - 6.2 6.3 6.5 - 6.6 6.8 7.0 - 7.1 7.2 7.5 - 7.5 7.7 7.9 -

HI PR 206 221 225 - 233 250 254 - 265 285 289 - 302 324 329 - 326 350 355 - 386 415 421 -

Lo PR 122 125 137 - 125 129 141 - 129 133 146 - 133 137 150 - 135 140 153 - 139 143 156 -

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 5 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 5 · clicca per ingrandire
Pagina 5

Expanded Cooling Data – DSXC180361A* / CA*F4961*6**+TXV / MBVC2000**-1 Low Stage (cont.)

21.8 22.3 23.3 24.9 1.00 1.00 0.99 0.80 22 22 23 20 1.73 1.77 1.84 1.90 7.6 7.8 8.1 8.4 394 423 429 439 142 146 159 17021.2 21.6 22.6 24.1 1.00 1.00 0.95 0.77 24 24 24 21 1.72 1.76 1.82 1.88 7.6 7.7 8.0 8.3 390 419 425 435 140 145 158 16819.6 19.9 20.9 22.3 1.00 1.00 0.91 0.74 25 25 24 21 1.70 1.74 1.80 1.87 7.5 7.7 7.9 8.2 386 415 421 430 139 143 156 166 23.6 24.0 25.2 26.8 1.00 1.00 0.98 0.80 23 24 24 21 1.67 1.71 1.77 1.83 7.2 7.4 7.6 7.9 332 357 362 370 138 143 156 16622.9 23.3 24.4 26.1 1.00 1.00 0.94 0.76 25 26 26 22 1.65 1.69 1.75 1.82 7.1 7.3 7.5 7.8 329 354 359 367 137 141 154 16421.1 21.5 22.5 24.1 1.00 1.00 0.90 0.73 27 27 26 23 1.64 1.68 1.74 1.80 7.1 7.2 7.5 7.8 326 350 355 363 135 140 153 162 24.8 25.3 26.5 28.3 1.00 1.00 0.95 0.77 25 25 25 21 1.60 1.63 1.69 1.75 6.7 6.9 7.1 7.4 308 331 335 343 135 140 153 16224.1 24.6 25.7 27.4 1.00 1.00 0.90 0.73 27 27 26 22 1.58 1.62 1.68 1.74 6.7 6.8 7.1 7.4 305 327 332 339 134 138 151 16122.2 22.7 23.7 25.3 1.00 0.97 0.87 0.71 28 28 26 23 1.57 1.60 1.66 1.72 6.6 6.8 7.0 7.3 302 324 329 336 133 137 150 159 25.4 25.9 27.1 29.0 1.00 1.00 0.92 0.74 25 26 25 21 1.51 1.55 1.60 1.66 6.3 6.5 6.7 6.9 270 290 295 301 132 136 149 15824.7 25.2 26.4 28.1 1.00 0.97 0.88 0.71 28 27 26 22 1.50 1.53 1.59 1.64 6.2 6.4 6.6 6.9 267 288 292 298 131 135 147 15722.8 23.2 24.3 26.0 0.97 0.93 0.84 0.68 28 28 26 23 1.48 1.52 1.57 1.63 6.2 6.3 6.5 6.8 265 285 289 295 129 133 146 155 26.0 26.6 27.8 29.7 1.00 0.99 0.89 0.73 26 26 25 21 1.41 1.45 1.50 1.55 5.8 5.9 6.1 6.4 237 255 259 265 128 132 144 15325.3 25.8 27.0 28.8 0.98 0.95 0.85 0.69 28 27 26 22 1.40 1.43 1.48 1.54 5.7 5.9 6.1 6.3 235 253 256 262 126 130 142 15223.3 23.8 24.9 26.6 0.94 0.91 0.82 0.67 28 28 26 23 1.39 1.42 1.47 1.52 5.7 5.8 6.0 6.2 233 250 254 259 125 129 141 150 26.7 27.2 28.5 30.4 0.99 0.96 0.86 0.70 26 26 24 21 1.30 1.33 1.38 1.43 5.3 5.5 5.7 5.9 210 226 229 234 124 128 140 14925.9 26.4 27.6 29.5 0.95 0.91 0.82 0.67 27 27 25 22 1.29 1.32 1.37 1.42 5.3 5.4 5.6 5.8 208 224 227 232 123 127 138 14723.9 24.4 25.5 27.2 0.91 0.88 0.79 0.64 27.8 27 26 22 1.28 1.31 1.36 1.40 5.2 5.4 5.5 5.8 206 221 225 230 122 125 137 146 MBh S/T ∆T kW Amps HI PR Lo PRMBh S/T ∆T kW Amps HI PR Lo PRMBh S/T ∆T kW Amps HI PR Lo PR 930825720 85

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 6 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 6 · clicca per ingrandire
Pagina 6

Expanded Cooling Data – DSXC180361A* / CA*F4961*6**+TXV / MBVC2000**-1 High Stage

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

MBh 36.7 38.1 41.7 - 35.9 37.2 40.7 - 35.0 36.3 39.8 - 34.2 35.4 38.8 - 32.4 33.6 36.8 - 30.1 31.2 34.1 -

S/T 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -

∆T 19 16 12 - 19 16 12 - 19 16 12 - 19 17 13 - 19 16 12 - 18 15 12 -

kW 2.09 2.14 2.21 - 2.26 2.31 2.39 - 2.41 2.47 2.56 - 2.55 2.61 2.70 - 2.66 2.73 2.82 - 2.76 2.83 2.93 -

Amps 8.2 8.4 8.7 - 8.9 9.1 9.4 - 9.7 9.9 10.3 - 10.4 10.7 11.0 - 11.1 11.4 11.8 - 11.8 12.1 12.5 -

HI PR 220 237 240 - 249 268 271 - 283 304 309 - 322 347 352 - 348 374 380 - 413 444 450 -

Lo PR 118 122 133 - 122 126 137 - 126 130 142 - 129 134 146 - 132 136 149 - 135 140 152 -

MBh 35.6 36.9 40.5 - 34.8 36.1 39.5 - 34.0 35.2 38.6 - 33.2 34.4 37.7 - 31.5 32.7 35.8 - 29.2 30.2 33.1 -

S/T 0.70 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.62 0.43 - 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.81 0.67 0.47 -

∆T 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 -

kW 2.07 2.12 2.19 - 2.24 2.29 2.37 - 2.39 2.45 2.53 - 2.53 2.59 2.68 - 2.64 2.70 2.80 - 2.74 2.80 2.90 -

Amps 8.1 8.3 8.6 - 8.8 9.0 9.3 - 9.6 9.9 10.2 - 10.3 10.6 10.9 - 11.0 11.3 11.7 - 11.7 12.0 12.4 -

HI PR 218 234 238 - 246 265 269 - 280 301 306 - 319 343 348 - 345 371 376 - 409 439 446 -

Lo PR 117 121 132 - 121 125 136 - 125 129 141 - 128 132 144 - 131 135 147 - 134 138 151 -

MBh 32.9 34.1 37.4 - 32.1 33.3 36.5 - 31.4 32.5 35.6 - 30.6 31.7 34.8 - 29.1 30.1 33.0 - 26.9 27.9 30.6 -

S/T 0.68 0.57 0.39 - 0.70 0.59 0.41 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.65 0.45 - 0.78 0.65 0.45 -

∆T 20 17 13 - 20 18 13 - 20 18 13 - 20 18 13 - 20 17 13 - 19 16 12 -

kW 2.05 2.10 2.17 - 2.22 2.27 2.35 - 2.37 2.43 2.51 - 2.50 2.56 2.65 - 2.62 2.68 2.77 - 2.71 2.78 2.88 -

Amps 8.1 8.3 8.5 - 8.7 9.0 9.3 - 9.5 9.8 10.1 - 10.2 10.5 10.8 - 10.9 11.2 11.5 - 11.6 11.8 12.3 -

HI PR 216 232 235 - 244 262 266 - 278 298 303 - 316 340 345 - 341 367 372 - 405 435 441 -

Lo PR 116 120 131 - 120 123 135 - 124 127 139 - 127 131 143 - 129 134 146 - 133 137 149 -

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 7 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 7 · clicca per ingrandire
Pagina 7

Expanded Cooling Data – DSXC180361A* / CA*F4961*6**+TXV / MBVC2000**-1 High Stage (cont.)

31.7 32.3 33.8 36.1 1.00 1.00 0.96 0.78 22 22 23 19 2.76 2.83 2.93 3.03 11.8 12.1 12.5 13.0 413 444 450 460 135 140 152 16230.7 31.3 32.8 35.0 1.00 1.00 0.92 0.75 24 25 24 20 2.74 2.80 2.90 3.01 11.7 12.0 12.4 12.9 409 439 446 455 134 138 151 16128.4 28.9 30.3 32.3 1.00 0.98 0.89 0.72 25 25 24 21 2.71 2.78 2.88 2.98 11.6 11.8 12.3 12.7 405 435 441 451 133 137 149 159 34.2 34.8 36.5 38.9 1.00 1.00 0.96 0.78 24 24 24 21 2.66 2.73 2.82 2.92 11.1 11.4 11.8 12.2 348 374 380 388 132 136 149 15833.2 33.8 35.4 37.8 1.00 1.00 0.91 0.74 26 26 25 22 2.64 2.70 2.80 2.90 11.0 11.3 11.7 12.1 345 371 376 384 131 135 147 15730.6 31.2 32.7 34.9 1.00 0.97 0.88 0.71 27 27 26 22 2.62 2.68 2.77 2.87 10.9 11.2 11.5 12.0 341 367 372 380 129 134 146 155 36.0 36.7 38.4 41.0 1.00 1.00 0.92 0.75 25 25 24 21 2.55 2.61 2.70 2.80 10.4 10.7 11.0 11.5 322 347 352 359 129 134 146 15534.9 35.6 37.3 39.8 1.00 0.97 0.88 0.71 27 27 26 22 2.53 2.59 2.68 2.77 10.3 10.6 10.9 11.4 319 343 348 356 128 132 144 15432.2 32.9 34.4 36.7 0.97 0.94 0.85 0.69 28 28 26 23 2.50 2.56 2.65 2.75 10.2 10.5 10.8 11.2 316 340 345 352 127 131 143 152 36.9 37.6 39.4 42.0 1.00 0.99 0.89 0.72 25 26 24 21 2.41 2.47 2.56 2.65 9.7 9.9 10.3 10.7 283 304 309 316 126 130 142 15135.8 36.5 38.2 40.8 0.98 0.94 0.85 0.69 27 27 25 22 2.39 2.45 2.53 2.62 9.6 9.9 10.2 10.6 280 301 306 312 125 129 141 15033.0 33.7 35.3 37.6 0.94 0.91 0.82 0.67 28 27 26 22 2.37 2.43 2.51 2.60 9.5 9.8 10.1 10.5 278 298 303 309 124 127 139 148 37.8 38.5 40.3 43.0 1.00 0.96 0.87 0.71 26 26 24 21 2.26 2.31 2.39 2.48 8.9 9.1 9.4 9.8 249 268 271 277 122 126 137 14636.7 37.4 39.1 41.8 0.95 0.92 0.83 0.67 27 27 25 22 2.24 2.29 2.37 2.45 8.8 9.0 9.3 9.7 246 265 269 275 121 125 136 14533.8 34.5 36.1 38.5 0.92 0.89 0.80 0.65 28 27 26 22 2.22 2.27 2.35 2.43 8.7 9.0 9.3 9.6 244 262 266 272 120 123 135 143 38.7 39.4 41.3 44.0 0.96 0.93 0.84 0.68 26 25 24 21 2.09 2.14 2.21 2.28 8.2 8.4 8.7 9.0 220 237 240 245 118 122 133 14237.5 38.3 40.1 42.8 0.92 0.89 0.80 0.65 27 27 25 22 2.07 2.12 2.19 2.26 8.1 8.3 8.6 9.0 218 234 238 243 117 121 132 14134.6 35.3 37.0 39.5 0.89 0.86 0.77 0.63 28 27 26 22 2.05 2.10 2.17 2.24 8.1 8.3 8.5 8.9 216 232 235 241 116 120 131 139 MBh S/T ∆T kW Amps HI PR Lo PRMBh S/T ∆T kW Amps HI PR Lo PRMBh S/T ∆T kW Amps HI PR Lo PR 133011751025 85

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 8 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 8 · clicca per ingrandire
Pagina 8

Expanded Cooling Data – DSXC180481A* / CA*F4961*6**+TXV / MBVC2000**-1 Low Stage

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

MBh 34.6 35.8 39.3 - 33.8 35.0 38.3 - 33.0 34.2 37.4 - 32.2 33.3 36.5 - 30.5 31.7 34.7 - 28.3 29.3 32.1 -

S/T 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.83 0.70 0.48 - 0.87 0.72 0.50 - 0.87 0.73 0.51 -

∆T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -

kW 1.87 1.91 1.97 - 2.02 2.07 2.14 - 2.16 2.21 2.29 - 2.28 2.34 2.42 - 2.39 2.44 2.53 - 2.47 2.53 2.62 -

Amps 7.2 7.4 7.6 - 7.8 8.0 8.3 - 8.5 8.7 9.0 - 9.1 9.4 9.7 - 9.7 10.0 10.3 - 10.4 10.6 11.0 -

HI PR 216 232 235 - 244 262 266 - 277 298 303 - 316 340 345 - 356 382 388 - 398 428 434 -

Lo PR 121 125 137 - 125 129 141 - 129 133 146 - 133 137 149 - 135 140 152 - 139 143 156 -

MBh 33.6 34.8 38.1 - 32.8 34.0 37.2 - 32.0 33.2 36.3 - 31.2 32.4 35.5 - 29.7 30.7 33.7 - 27.5 28.5 31.2 -

S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.64 0.45 - 0.80 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -

∆T 19 16 13 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 16 12 -

kW 1.85 1.89 1.96 - 2.00 2.05 2.12 - 2.14 2.19 2.27 - 2.26 2.32 2.40 - 2.36 2.42 2.51 - 2.45 2.51 2.60 -

Amps 7.1 7.3 7.6 - 7.7 7.9 8.2 - 8.4 8.7 9.0 - 9.0 9.3 9.6 - 9.7 9.9 10.2 - 10.3 10.5 10.9 -

HI PR 214 230 233 - 242 260 263 - 275 295 300 - 313 336 341 - 352 378 384 - 394 424 430 -

Lo PR 120 124 135 - 124 128 139 - 128 132 144 - 131 136 148 - 134 138 151 - 137 142 155 -

MBh 31.0 32.1 35.2 - 30.3 31.4 34.4 - 29.5 30.6 33.5 - 28.8 29.9 32.7 - 27.4 28.4 31.1 - 25.4 26.3 28.8 -

S/T 0.70 0.58 0.40 - 0.73 0.61 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.67 0.46 - 0.80 0.67 0.46 -

∆T 19 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 -

kW 1.83 1.88 1.94 - 1.99 2.03 2.10 - 2.12 2.17 2.25 - 2.24 2.29 2.38 - 2.34 2.40 2.48 - 2.43 2.49 2.58 -

Amps 7.1 7.2 7.5 - 7.7 7.9 8.1 - 8.4 8.6 8.9 - 9.0 9.2 9.5 - 9.6 9.8 10.1 - 10.2 10.4 10.8 -

HI PR 212 227 231 - 239 257 261 - 272 292 297 - 310 333 338 - 348 375 380 - 390 420 426 -

Lo PR 119 123 134 - 123 126 138 - 127 131 143 - 130 134 147 - 133 137 149 - 136 140 153 -

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 9 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 9 · clicca per ingrandire
Pagina 9

Expanded Cooling Data – DSXC180481A* / CA*F4961*6**+TXV / MBVC2000**-1 Low Stage (cont.)

29.8 30.4 31.8 33.9 1.00 1.00 0.99 0.81 21 21 22 19 2.47 2.53 2.62 2.72 10.4 10.6 11.0 11.4 398 428 434 444 139 143 156 16628.9 29.5 30.9 33.0 1.00 1.00 0.95 0.77 23 23 23 20 2.45 2.51 2.60 2.69 10.3 10.5 10.9 11.3 394 424 430 439 137 142 155 16526.7 27.2 28.5 30.4 1.00 1.00 0.91 0.74 24 24 23 20 2.43 2.49 2.58 2.67 10.2 10.4 10.8 11.2 390 420 426 435 136 140 153 163 32.2 32.8 34.3 36.6 1.00 1.00 0.99 0.80 22 23 23 20 2.39 2.44 2.53 2.62 9.7 10.0 10.3 10.8 356 382 388 396 135 140 152 16231.2 31.8 33.3 35.6 1.00 1.00 0.94 0.76 24 25 25 21 2.36 2.42 2.51 2.60 9.7 9.9 10.2 10.6 352 378 384 392 134 138 151 16128.8 29.4 30.8 32.8 1.00 1.00 0.91 0.74 26 26 25 22 2.34 2.40 2.48 2.57 9.6 9.8 10.1 10.5 348 375 380 388 133 137 149 159 33.9 34.5 36.2 38.6 1.00 1.00 0.95 0.77 23 24 24 21 2.28 2.34 2.42 2.51 9.1 9.4 9.7 10.1 316 340 345 352 133 137 149 15932.9 33.5 35.1 37.4 1.00 1.00 0.91 0.74 26 26 25 22 2.26 2.32 2.40 2.48 9.0 9.3 9.6 10.0 313 336 341 349 131 136 148 15830.3 30.9 32.4 34.6 1.00 0.97 0.87 0.71 27 27 25 22 2.24 2.29 2.38 2.46 9.0 9.2 9.5 9.9 310 333 338 345 130 134 147 156 34.7 35.4 37.1 39.5 1.00 1.00 0.92 0.75 24 25 24 20 2.16 2.21 2.29 2.37 8.5 8.7 9.0 9.4 277 298 303 309 129 133 146 15533.7 34.4 36.0 38.4 1.00 0.97 0.88 0.71 26 26 25 21 2.14 2.19 2.27 2.35 8.4 8.7 9.0 9.3 275 295 300 306 128 132 144 15431.1 31.7 33.2 35.4 0.97 0.94 0.85 0.69 27 27 25 22 2.12 2.17 2.25 2.33 8.4 8.6 8.9 9.2 272 292 297 303 127 131 143 152 35.6 36.2 38.0 40.5 1.00 0.99 0.90 0.73 25 25 24 20 2.02 2.07 2.14 2.22 7.8 8.0 8.3 8.6 244 262 266 272 125 129 141 15034.5 35.2 36.9 39.3 0.98 0.95 0.86 0.69 27 26 25 21 2.00 2.05 2.12 2.20 7.7 7.9 8.2 8.5 242 260 263 269 124 128 139 14831.9 32.5 34.0 36.3 0.95 0.91 0.83 0.67 27 27 25 22 1.99 2.03 2.10 2.18 7.7 7.9 8.1 8.4 239 257 261 267 123 126 138 147 36.4 37.1 38.9 41.5 0.99 0.96 0.87 0.70 25 25 23 20 1.87 1.91 1.97 2.04 7.2 7.4 7.6 7.9 216 232 235 241 121 125 137 14635.3 36.0 37.7 40.3 0.95 0.92 0.83 0.67 26 26 24 21 1.85 1.89 1.96 2.03 7.1 7.3 7.6 7.9 214 230 233 238 120 124 135 14432.6 33.3 34.8 37.2 0.91 0.88 0.80 0.65 26.8 26 25 22 1.83 1.88 1.94 2.01 7.1 7.2 7.5 7.8 212 227 231 236 119 123 134 143 MBh S/T ∆T kW Amps HI PR Lo PRMBh S/T ∆T kW Amps HI PR Lo PRMBh S/T ∆T kW Amps HI PR Lo PR 132511751025 85

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 10 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 10 · clicca per ingrandire
Pagina 10

Expanded Cooling Data – DSXC180481A* / CA*F4961*6**+TXV / MBVC2000**-1 High Stage

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

MBh 48.2 50.0 54.8 - 47.1 48.8 53.5 - 46.0 47.7 52.2 - 44.9 46.5 50.9 - 42.6 44.2 48.4 - 39.5 40.9 44.8 -

S/T 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.87 0.73 0.50 - 0.88 0.73 0.51 -

∆T 17 15 11 - 17 15 11 - 17 15 11 - 18 15 12 - 17 15 11 - 16 14 11 -

kW 2.87 2.94 3.03 - 3.10 3.17 3.27 - 3.30 3.37 3.48 - 3.47 3.55 3.67 - 3.62 3.70 3.83 - 3.75 3.84 3.97 -

Amps 10.2 10.5 10.8 - 11.1 11.4 11.7 - 12.1 12.4 12.8 - 13.0 13.3 13.7 - 13.8 14.2 14.7 - 14.7 15.1 15.6 -

HI PR 228 245 248 - 257 277 280 - 292 315 319 - 333 358 363 - 375 403 409 - 420 451 458 -

Lo PR 121 124 136 - 124 128 140 - 128 132 145 - 132 136 148 - 134 139 151 - 138 142 155 -

MBh 46.8 48.5 53.2 - 45.7 47.4 51.9 - 44.6 46.3 50.7 - 43.5 45.1 49.5 - 41.4 42.9 47.0 - 38.3 39.7 43.5 -

S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.84 0.70 0.48 -

∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -

kW 2.85 2.91 3.01 - 3.07 3.14 3.24 - 3.27 3.34 3.45 - 3.44 3.52 3.64 - 3.59 3.67 3.80 - 3.72 3.80 3.93 -

Amps 10.1 10.4 10.7 - 11.0 11.2 11.6 - 12.0 12.3 12.7 - 12.8 13.2 13.6 - 13.7 14.0 14.5 - 14.5 14.9 15.4 -

HI PR 225 242 246 - 255 274 278 - 290 311 316 - 330 355 360 - 371 399 405 - 416 447 453 -

Lo PR 119 123 134 - 123 127 138 - 127 131 143 - 130 135 147 - 133 137 150 - 136 141 154 -

MBh 43.2 44.8 49.1 - 42.2 43.7 47.9 - 41.2 42.7 46.8 - 40.2 41.7 45.6 - 38.2 39.6 43.4 - 35.4 36.7 40.2 -

S/T 0.70 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.62 0.43 - 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.81 0.67 0.47 -

∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -

kW 2.83 2.89 2.98 - 3.05 3.12 3.22 - 3.24 3.32 3.43 - 3.42 3.49 3.61 - 3.56 3.64 3.76 - 3.69 3.77 3.90 -

Amps 10.0 10.3 10.6 - 10.9 11.1 11.5 - 11.9 12.2 12.6 - 12.7 13.0 13.5 - 13.6 13.9 14.4 - 14.4 14.8 15.3 -

HI PR 223 240 243 - 252 271 275 - 287 308 313 - 327 351 356 - 367 395 401 - 411 442 449 -

Lo PR 118 122 133 - 122 125 137 - 126 130 142 - 129 133 145 - 132 136 148 - 135 139 152 -

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 11 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 11 · clicca per ingrandire
Pagina 11

Expanded Cooling Data – DSXC180481A* / CA*F4961*6**+TXV / MBVC2000**-1 High Stage (cont.)

41.6 42.4 44.4 47.3 1.00 1.00 1.00 0.81 19 20 21 18 3.75 3.84 3.97 4.10 14.7 15.1 15.6 16.2 420 451 458 468 138 142 155 16540.4 41.1 43.1 46.0 1.00 1.00 0.95 0.77 21 22 22 19 3.72 3.80 3.93 4.07 14.5 14.9 15.4 16.0 416 447 453 463 136 141 154 16337.3 38.0 39.8 42.4 1.00 1.00 0.92 0.75 22 23 22 19 3.69 3.77 3.90 4.03 14.4 14.8 15.3 15.9 411 442 449 459 135 139 152 162 44.9 45.7 47.9 51.1 1.00 1.00 0.99 0.80 21 21 22 19 3.62 3.70 3.83 3.96 13.8 14.2 14.7 15.3 375 403 409 418 134 139 151 16143.6 44.4 46.5 49.6 1.00 1.00 0.95 0.77 23 23 23 20 3.59 3.67 3.80 3.93 13.7 14.0 14.5 15.1 371 399 405 414 133 137 150 16040.2 41.0 42.9 45.8 1.00 1.00 0.91 0.74 24 25 24 20 3.56 3.64 3.76 3.89 13.6 13.9 14.4 15.0 367 395 401 409 132 136 148 158 47.2 48.2 50.4 53.8 1.00 1.00 0.96 0.78 22 22 22 19 3.47 3.55 3.67 3.80 13.0 13.3 13.7 14.3 333 358 363 371 132 136 148 15845.9 46.7 49.0 52.2 1.00 1.00 0.91 0.74 24 25 23 20 3.44 3.52 3.64 3.76 12.8 13.2 13.6 14.2 330 355 360 368 130 135 147 15642.3 43.1 45.2 48.2 1.00 0.97 0.88 0.71 25 25 24 21 3.42 3.49 3.61 3.73 12.7 13.0 13.5 14.0 327 351 356 364 129 133 145 155 48.4 49.4 51.7 55.1 1.00 1.00 0.93 0.75 23 23 22 19 3.30 3.37 3.48 3.60 12.1 12.4 12.8 13.3 292 315 319 326 128 132 145 15447.0 47.9 50.2 53.5 1.00 0.98 0.88 0.72 25 25 23 20 3.27 3.34 3.45 3.57 12.0 12.3 12.7 13.2 290 311 316 323 127 131 143 15243.4 44.2 46.3 49.4 0.98 0.94 0.85 0.69 25 25 24 21 3.24 3.32 3.43 3.54 11.9 12.2 12.6 13.1 287 308 313 320 126 130 142 151 49.6 50.6 53.0 56.5 1.00 1.00 0.90 0.73 23 24 22 19 3.10 3.17 3.27 3.38 11.1 11.4 11.7 12.2 257 277 280 287 124 128 140 14948.2 49.1 51.4 54.8 0.99 0.95 0.86 0.70 25 25 23 20 3.07 3.14 3.24 3.35 11.0 11.2 11.6 12.1 255 274 278 284 123 127 138 14744.4 45.3 47.5 50.6 0.95 0.92 0.83 0.67 25 25 24 20 3.05 3.12 3.22 3.32 10.9 11.1 11.5 12.0 252 271 275 281 122 125 137 146 50.8 51.8 54.2 57.8 1.00 0.97 0.87 0.71 24 23 22 19 2.87 2.94 3.03 3.13 10.2 10.5 10.8 11.2 228 245 248 254 121 124 136 14549.3 50.3 52.6 56.2 0.95 0.92 0.83 0.67 25 24 23 20 2.85 2.91 3.01 3.10 10.1 10.4 10.7 11.1 225 242 246 251 119 123 134 14345.5 46.4 48.6 51.8 0.92 0.89 0.80 0.65 25 25 23 20 2.83 2.89 2.98 3.08 10.0 10.3 10.6 11.0 223 240 243 249 118 122 133 142 MBh S/T ∆T kW Amps HI PR Lo PRMBh S/T ∆T kW Amps HI PR Lo PRMBh S/T ∆T kW Amps HI PR Lo PR 197017501530 85

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 12 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 12 · clicca per ingrandire
Pagina 12

Expanded Cooling Data – DSXC180601A* / CA*F4961*6** +TXV / MBVC2000**-1 Low Stage

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

MBh 42.4 43.9 48.1 - 41.4 42.9 47.0 - 40.4 41.9 45.9 - 39.4 40.8 44.7 - 37.4 38.8 42.5 - 34.7 35.9 39.4 -

S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -

∆T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -

kW 2.43 2.49 2.57 - 2.64 2.70 2.79 - 2.82 2.89 2.99 - 2.98 3.05 3.16 - 3.12 3.19 3.31 - 3.24 3.31 3.43 -

Amps 9.4 9.6 10.0 - 10.2 10.4 10.8 - 11.1 11.4 11.8 - 11.9 12.2 12.6 - 14.0 14.3 14.8 - 14.8 15.1 15.7 -

HI PR 226 243 247 - 248 267 271 - 291 313 317 - 331 356 361 - 372 400 406 - 430 463 469 -

Lo PR 118 122 133 - 121 125 137 - 125 129 141 - 129 133 145 - 131 136 148 - 135 139 152 -

MBh 41.1 42.6 46.7 - 40.2 41.6 45.6 - 39.2 40.6 44.5 - 38.3 39.6 43.4 - 36.3 37.7 41.3 - 33.7 34.9 38.2 -

S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -

∆T 19 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 -

kW 2.41 2.47 2.55 - 2.61 2.68 2.77 - 2.80 2.86 2.96 - 2.95 3.03 3.13 - 3.09 3.16 3.28 - 3.21 3.28 3.40 -

Amps 9.3 9.5 9.9 - 10.1 10.3 10.7 - 11.0 11.3 11.7 - 11.8 12.1 12.5 - 13.8 14.2 14.7 - 14.6 15.0 15.5 -

HI PR 224 241 244 - 246 264 268 - 288 309 314 - 328 352 357 - 369 397 402 - 426 458 465 -

Lo PR 117 120 131 - 120 124 135 - 124 128 140 - 128 132 144 - 130 134 146 - 133 137 150 -

MBh 38.0 39.3 43.1 - 37.1 38.4 42.1 - 36.2 37.5 41.1 - 35.3 36.6 40.1 - 33.5 34.8 38.1 - 31.1 32.2 35.3 -

S/T 0.67 0.56 0.39 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.64 0.44 - 0.77 0.64 0.44 -

∆T 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 19 16 12 -

kW 2.39 2.44 2.53 - 2.59 2.65 2.75 - 2.77 2.84 2.94 - 2.93 3.00 3.10 - 3.06 3.14 3.25 - 3.18 3.25 3.37 -

Amps 9.2 9.4 9.8 - 10.0 10.2 10.6 - 10.9 11.2 11.6 - 11.7 12.0 12.4 - 13.7 14.0 14.5 - 14.5 14.8 15.4 -

HI PR 222 238 242 - 243 262 265 - 285 306 311 - 325 349 354 - 365 393 398 - 422 454 460 -

Lo PR 116 119 130 - 119 123 134 - 123 127 138 - 126 130 142 - 129 133 145 - 132 136 149 -

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 13 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 13 · clicca per ingrandire
Pagina 13

Expanded Cooling Data – DSXC180601A* / CA*F4961*6** +TXV / MBVC2000**-1 Low Stage (cont.)

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 14 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 14 · clicca per ingrandire
Pagina 14

Expanded Cooling Data – DSXC180601A* / CA*F4961*6** +TXV / MBVC2000**-1 High Stage

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

MBh 58.5 60.6 66.4 - 57.1 59.2 64.9 - 55.8 57.8 63.3 - 54.4 56.4 61.8 - 51.7 53.6 58.7 - 47.9 49.6 54.4 -

S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.47 - 0.83 0.70 0.48 - 0.84 0.70 0.49 -

∆T 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -

kW 3.87 3.96 4.09 - 4.18 4.27 4.41 - 4.45 4.55 4.70 - 4.69 4.80 4.96 - 4.89 5.00 5.17 - 5.07 5.18 5.36 -

Amps 13.8 14.2 14.7 - 15.0 15.4 15.9 - 16.4 16.8 17.4 - 17.6 18.0 18.7 - 20.6 21.2 21.9 - 21.8 22.4 23.2 -

HI PR 241 259 263 - 265 285 289 - 310 333 338 - 353 380 385 - 397 427 433 - 459 493 500 -

Lo PR 115 119 130 - 118 122 133 - 123 126 138 - 126 130 142 - 128 132 144 - 131 136 148 -

MBh 56.8 58.9 64.5 - 55.5 57.5 63.0 - 54.2 56.1 61.5 - 52.8 54.8 60.0 - 50.2 52.0 57.0 - 46.5 48.2 52.8 -

S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -

∆T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -

kW 3.84 3.93 4.05 - 4.15 4.24 4.38 - 4.41 4.51 4.66 - 4.65 4.75 4.91 - 4.85 4.96 5.13 - 5.02 5.14 5.31 -

Amps 13.7 14.0 14.5 - 14.9 15.2 15.8 - 16.2 16.6 17.2 - 17.4 17.8 18.5 - 20.4 21.0 21.7 - 21.6 22.2 23.0 -

HI PR 239 257 260 - 262 282 286 - 307 330 335 - 349 376 381 - 393 423 429 - 454 488 495 -

Lo PR 114 118 128 - 117 121 132 - 121 125 137 - 125 128 140 - 127 131 143 - 130 134 147 -

MBh 52.4 54.3 59.5 - 51.2 53.1 58.1 - 50.0 51.8 56.8 - 48.8 50.5 55.4 - 46.3 48.0 52.6 - 42.9 44.5 48.7 -

S/T 0.67 0.56 0.39 - 0.70 0.58 0.40 - 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.77 0.65 0.45 -

∆T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -

kW 3.81 3.89 4.02 - 4.11 4.20 4.34 - 4.38 4.47 4.62 - 4.61 4.71 4.87 - 4.81 4.92 5.08 - 4.98 5.09 5.27 -

Amps 13.5 13.9 14.4 - 14.7 15.1 15.6 - 16.1 16.5 17.1 - 17.2 17.7 18.3 - 20.2 20.8 21.5 - 21.4 22.0 22.7 -

HI PR 236 254 258 - 259 279 283 - 304 327 331 - 346 372 377 - 389 419 424 - 450 484 490 -

Lo PR 113 116 127 - 116 120 131 - 120 124 135 - 123 127 139 - 126 130 142 - 129 133 145 -

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 15 of the Goodmans Air Conditioner (DSXC18) user manual — Expanded Cooling Data
Pagina 15 · clicca per ingrandire
Pagina 15

Expanded Cooling Data – DSXC180601A* / CA*F4961*6** +TXV / MBVC2000**-1 High Stage (cont.)

IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions kW = Total system power

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temperature

Page 16 of the Goodmans Air Conditioner (DSXC18) user manual — DSXC18 0361A*
Pagina 16 · clicca per ingrandire
Pagina 16

AHRI R atings

Indoor Units Cooling Ratings CFM AHRI # Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³

AVPTC42D14A* 35,000 26,600 17.00 13.00 1,280 5924367 AVPTC48D14A* 36,000 27,400 17.50 13.00 1,200 5924368 CA*F3743*6D*+EEP+TXV 35,000 26,600 15.00 12.50 1,250 5357210 CA*F3743*6D*+MBVC1600**-1A*+TXV 35,000 26,600 18.00 13.00 1,200 4415028 CA*F3743*6D*+MBVC2000**-1A*+TXV 35,000 26,600 18.00 13.00 1,200 4415029 CA*F3743*6D*+TXV G*VC80805C*B* 35,000 26,600 17.00 13.00 1,190 5038938 CA*F3743*6D*+TXV A*VC80805C*B* 35,000 26,600 17.00 13.00 1,190 5038941 CA*F3743*6D*+TXV A*VC80604B*B* 35,000 26,600 17.00 13.00 1,220 5038969 CA*F3743*6D*+TXV ADVC80805C*B* 35,000 26,600 17.00 13.00 1,190 5039119 CA*F3743*6D*+TXV G*VC91155DXA* 35,000 26,600 18.00 13.00 1,225 4415050 CA*F3743*6D*+TXV G*VC80604B*B* 35,000 26,600 17.00 13.00 1,220 5038845 CA*F3743*6D*+TXV G*VC950704CXB* 35,000 26,600 17.50 13.00 1,250 5620824 CA*F3743*6D*+TXV G*VC950905CXB* 35,000 26,600 18.00 13.25 1,200 5620835 CA*F3743*6D*+TXV A*VC950915DXB* 35,000 26,600 18.00 13.25 1,250 5620851 CA*F3743*6D*+TXV G*VM960805DXB* 35,000 26,600 18.00 13.25 1,250 5620886 CA*F3743*6D*+TXV A*VC950714CXB* 35,000 26,600 17.50 13.00 1,275 5620831 CA*F3743*6D*+TXV G*VC950915DXB* 35,000 26,600 18.00 13.25 1,250 5620852 CA*F3743*6D*+TXV G*VC951155DXB* 35,000 26,600 18.00 13.00 1,225 5620857 CA*F3743*6D*+TXV G*VM961005DXB* 35,000 26,600 18.00 13.00 1,225 5620893 CA*F3743*6D*+TXV G*VM961155DXB* 35,000 26,600 18.00 13.00 1,225 5620899 CA*F3743*6D*+TXV G*VM960604CXB* 35,000 26,600 17.50 13.00 1,250 5620868 CA*F3743*6D*+TXV G*VC950905DXB* 35,000 26,600 18.00 13.25 1,200 5620843 CA*F3743*6D*+TXV A*VC950905CXB* 35,000 26,600 18.00 13.25 1,200 6497751 CA*F3743*6D*+TXV A*VM961005DXB* 35,000 26,600 18.00 13.00 1,225 6497755 CA*F3743*6D*+TXV A*VM961155DXB* 35,000 26,600 18.00 13.00 1,225 6497756 CA*F3743*6D*+TXV A*VC950905DXB* 35,000 26,600 18.00 13.25 1,250 6497752 CA*F3743*6D*+TXV G*VC81005C*B* 35,000 26,600 17.00 13.00 1,210 6497758 CA*F3743*6D*+TXV A*VC81005C*B* 35,000 26,600 17.00 13.00 1,210 6497749 CA*F3743*6D*+TXV ADVC81005C*B* 35,000 26,600 17.00 13.00 1,230 6497757 CA*F3743*6D*+TXV G*VC950714CXB* 35,000 26,600 17.50 13.00 1,250 5620832 CA*F3743*6D*+TXV A*VM960604CXB* 35,000 26,600 17.50 13.00 1,275 5620867 CA*F3743*6D*+TXV G*VM960805CXB* 35,000 26,600 18.00 13.25 1,200 5620879 CA*F3743*6D*+TXV A*VC950704CXB* 35,000 26,600 17.50 13.00 1,275 6497750 CA*F3743*6D*+TXV A*VC951155DXB* 35,000 26,600 18.00 13.00 1,225 6497753 CA*F3743*6D*+TXV A*VM960805CXB* 35,000 26,600 18.00 13.25 1,200 6497754 CA*F4860*6D*+MBVC2000**-1A*+TXV 36,000 27,400 19.00 13.50 1,250 6497759 CA*F4860*6D*+TXV G*VC950905CXB* 35,000 26,600 17.50 13.00 1,225 5620836 CA*F4860*6D*+TXV A*VC950915DXB* 35,000 26,600 17.50 13.00 1,225 5620853 CA*F4860*6D*+TXV G*VM960805DXB* 35,000 26,600 17.50 13.00 1,225 5620887 CA*F4860*6D*+TXV G*VM960805CXB* 35,000 26,600 17.50 13.00 1,225 5620880 CA*F4860*6D*+TXV G*VC950915DXB* 35,000 26,600 17.50 13.00 1,225 5620854 CA*F4860*6D*+TXV A*VC950905CXB* 35,000 26,600 17.50 13.00 1,225 6497760 CA*F4860*6D*+TXV A*VC950905DXB* 35,000 26,600 17.50 13.00 1,225 6497761 CA*F4860*6D*+TXV A*VM960805DXB* 35,000 26,600 17.50 13.00 1,225 6497763 CA*F4860*6D*+TXV G*VC950905DXB* 35,000 26,600 17.50 13.00 1,225 5620844 CA*F4860*6D*+TXV A*VM960805CXB* 35,000 26,600 17.50 13.00 1,225 6497762 CA*F4961*6D*+EEP+TXV 36,000 27,400 15.00 12.50 1,250 5357211 CA*F4961*6D*+MBVC1600**-1A*+TXV 36,000 27,400 17.50 13.00 1,200 4431665 CA*F4961*6D*+MBVC2000**-1A*+TXV 36,000 27,400 19.00 13.50 1,250 4431666 CA*F4961*6D*+TXV G*VC80604B*B* 36,000 27,400 17.50 13.20 1,220 5039228 CA*F4961*6D*+TXV G*VC80805C*B* 36,000 27,400 18.00 13.70 1,190 5038816

DSXC18 0361A*

See Notes on Page 21.

Page 17 of the Goodmans Air Conditioner (DSXC18) user manual — AHRI R atings ( cont .)
Pagina 17 · clicca per ingrandire
Pagina 17

AHRI R atings ( cont .)

Indoor Units Cooling Ratings CFM AHRI # Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³

CA*F4961*6D*+TXV ADVC80805C*B* 36,000 27,400 18.00 13.70 1,190 5038968 CA*F4961*6D*+TXV A*VC80604B*B* 36,000 27,400 17.50 13.20 1,220 5038818 CA*F4961*6D*+TXV A*VC80805C*B* 36,000 27,400 18.00 13.70 1,190 5038942 CA*F4961*6D*+TXV G*VC950704CXB* 35,000 26,600 17.50 13.30 1,225 5620825 CA*F4961*6D*+TXV A*VC950714CXB* 35,000 26,600 17.50 13.30 1,225 5620833 CA*F4961*6D*+TXV A*VM960604CXB* 35,000 26,600 17.50 13.30 1,225 5620869 CA*F4961*6D*+TXV G*VM961005DXB* 36,000 27,400 18.30 13.25 1,225 5620894 CA*F4961*6D*+TXV G*VC950905CXB* 35,000 26,600 18.00 13.25 1,225 5620837 CA*F4961*6D*+TXV G*VC950714CXB* 35,000 26,600 17.50 13.30 1,225 5620834 CA*F4961*6D*+TXV G*VC951155DXB* 36,000 27,400 18.30 13.25 1,225 5620858 CA*F4961*6D*+TXV G*VM960604CXB* 35,000 26,600 17.50 13.30 1,225 5620870 CA*F4961*6D*+TXV G*VC950453BXB* 35,000 26,600 17.00 13.00 1,200 5620819 CA*F4961*6D*+TXV G*VC950905DXB* 35,000 26,600 18.00 13.50 1,225 5620845 CA*F4961*6D*+TXV A*VC950915DXB* 35,000 26,600 18.00 13.50 1,225 5620855 CA*F4961*6D*+TXV G*VC950915DXB* 35,000 26,600 18.00 13.50 1,225 5620856 CA*F4961*6D*+TXV G*VM960805CXB* 35,000 26,600 18.00 13.25 1,225 5620881 CA*F4961*6D*+TXV G*VM960805DXB* 35,000 26,600 18.00 13.50 1,225 5620888 CA*F4961*6D*+TXV A*VM960805CXB* 35,000 26,600 18.00 13.25 1,225 6497771 CA*F4961*6D*+TXV A*VC950453BXB* 35,000 26,600 17.00 13.00 1,200 6497765 CA*F4961*6D*+TXV A*VC951155DXB* 36,000 27,400 18.30 13.25 1,225 6497769 CA*F4961*6D*+TXV A*VM960603BXB* 35,000 26,600 17.00 13.00 1,200 6497770 CA*F4961*6D*+TXV G*VC81005C*B* 36,000 27,400 18.00 13.70 1,210 6497775 CA*F4961*6D*+TXV A*VC81005C*B* 36,000 27,400 18.00 13.70 1,210 6497764 CA*F4961*6D*+TXV A*VM961155DXB* 36,000 27,400 18.30 13.25 1,225 6497773 CA*F4961*6D*+TXV A*VC950704CXB* 35,000 26,600 17.50 13.30 1,225 6497766 CA*F4961*6D*+TXV A*VC950905CXB* 35,000 26,600 18.00 13.25 1,225 6497767 CA*F4961*6D*+TXV A*VM961005DXB* 36,000 27,400 18.30 13.25 1,225 6497772 CA*F4961*6D*+TXV G*VM960603BXB* 35,000 26,600 17.00 13.00 1,200 5620863 CA*F4961*6D*+TXV G*VM961155DXB* 36,000 27,400 18.30 13.25 1,225 5620900 CA*F4961*6D*+TXV A*VC950905DXB* 35,000 26,600 18.00 13.50 1,225 6497768 CA*F4961*6D*+TXV ADVC81005C*B* 36,000 27,400 18.00 13.70 1,230 6497774 CHPF3642C6C*+MBVC1600**-1A*+TXV 35,000 26,600 18.00 13.00 1,250 3654252 CHPF3642C6C*+TXV G*VM960604CXB* 35,000 26,600 17.50 13.00 1,275 5620872 CHPF3642C6C*+TXV G*VC950704CXB* 35,000 26,600 17.50 13.00 1,275 5620826 CHPF3642C6C*+TXV A*VM960604CXB* 35,000 26,600 17.50 13.00 1,275 5620871 CHPF3642C6C*+TXV A*VC950704CXB* 35,000 26,600 17.50 13.00 1,275 6497776 CHPF3642D6C*+MBVC2000**-1A*+TXV 35,000 26,600 18.00 13.00 1,250 3654256 CHPF3642D6C*+TXV G*VC950905DXB* 35,000 26,600 18.00 13.25 1,250 5620846 CHPF3642D6C*+TXV G*VM961005DXB* 35,000 26,600 18.00 13.00 1,225 5620895 CHPF3642D6C*+TXV G*VC951155DXB* 35,000 26,600 18.00 13.00 1,225 5620859 CHPF3642D6C*+TXV G*VM960805CXB* 35,000 26,600 18.00 13.25 1,250 5620882 CHPF3642D6C*+TXV G*VM960805DXB* 35,000 26,600 18.00 13.25 1,250 5620889 CHPF3642D6C*+TXV G*VC950905CXB* 35,000 26,600 18.00 13.25 1,250 5620838 CHPF3642D6C*+TXV G*VM961155DXB* 35,000 26,600 18.00 13.00 1,225 5620901 CHPF3642D6C*+TXV A*VC951155DXB* 35,000 26,600 18.00 13.00 1,225 6497779 CHPF3642D6C*+TXV A*VM961005DXB* 35,000 26,600 18.00 13.00 1,225 6497782 CHPF3642D6C*+TXV A*VM961155DXB* 35,000 26,600 18.00 13.00 1,225 6497783 CHPF3642D6C*+TXV A*VC950905DXB* 35,000 26,600 18.00 13.25 1,250 6497778 CHPF3642D6C*+TXV A*VC950905CXB* 35,000 26,600 18.00 13.25 1,250 6497777 CHPF3642D6C*+TXV A*VM960805DXB* 35,000 26,600 18.00 13.25 1,250 6497781 CHPF3642D6C*+TXV A*VM960805CXB* 35,000 26,600 18.00 13.25 1,250 6497780

DSXC18 0361A* (cont.)

See Notes on Page 21.

Page 18 of the Goodmans Air Conditioner (DSXC18) user manual — AHRI R atings ( cont .)
Pagina 18 · clicca per ingrandire
Pagina 18

AHRI R atings ( cont .)

Goodmans Air Conditioner (DSXC18) — AHRI R atings ( cont .) diagram (page 18)
Fig. 3 · AHRI R atings ( cont .)

Indoor Units Cooling Ratings CFM AHRI # Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³

See Notes on Page 21.

Page 19 of the Goodmans Air Conditioner (DSXC18) user manual — AHRI R atings ( cont .)
Pagina 19 · clicca per ingrandire
Pagina 19

AHRI R atings ( cont .)

Goodmans Air Conditioner (DSXC18) — AHRI R atings ( cont .) diagram (page 19)
Fig. 4 · AHRI R atings ( cont .)

Indoor Units Cooling Ratings CFM AHRI # Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³

See Notes on Page 21.

Page 20 of the Goodmans Air Conditioner (DSXC18) user manual — DSXC18 0481A*
Pagina 20 · clicca per ingrandire
Pagina 20

AHRI R atings ( cont .)

Indoor Units Cooling Ratings CFM AHRI # Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³

AVPTC48D14A* 47,000 35,800 17.50 13.00 1,700 5924369 CA*F4860*6D*+EEP+TXV 47,000 35,800 15.00 12.00 1,500 6497825 CA*F4961*6D*+EEP+TXV 48,000 36,400 15.50 12.50 1,500 5357214 CA*F4961*6D*+MBVC1600**-1A*+TXV 46,000 35,000 17.00 13.00 1,725 4431667 CA*F4961*6D*+MBVC2000**-1A*+TXV 47,500 36,200 18.00 13.25 1,750 4431668 CA*F4961*6D*+TXV G*VC91155DXA* 46,500 35,400 16.50 13.00 1,650 4431743 CA*F4961*6D*+TXV G*VC80805C*B* 48,000 36,400 17.00 12.80 1,590 5039230 CA*F4961*6D*+TXV ADVC80805C*B* 48,000 36,400 17.00 12.80 1,580 5039231 CA*F4961*6D*+TXV G*VC950714CXB* 46,000 35,000 17.00 13.00 1,725 5620906 CA*F4961*6D*+TXV A*VC950915DXB* 47,000 35,800 17.50 13.00 1,750 5620910 CA*F4961*6D*+TXV G*VC950915DXB* 47,000 35,800 17.50 13.00 1,750 5620911 CA*F4961*6D*+TXV G*VM961005DXB* 47,000 35,800 18.00 13.00 1,750 5620921 CA*F4961*6D*+TXV G*VM960805DXB* 47,000 35,800 17.50 13.00 1,750 5620919 CA*F4961*6D*+TXV A*VC950714CXB* 46,000 35,000 17.00 13.00 1,725 5620905 CA*F4961*6D*+TXV G*VC950905DXB* 47,000 35,800 17.50 13.00 1,750 5620908 CA*F4961*6D*+TXV G*VM961155DXB* 47,000 35,800 18.00 13.00 1,750 5620923 CA*F4961*6D*+TXV G*VC951155DXB* 47,000 35,800 18.00 13.00 1,750 5620912 CA*F4961*6D*+TXV A*VM960604CXB* 46,000 35,000 17.00 13.00 1,725 5620914 CA*F4961*6D*+TXV G*VM960604CXB* 46,000 35,000 17.00 13.00 1,725 5620915 CA*F4961*6D*+TXV A*VC950905CXB* 46,000 35,000 16.50 13.00 1,650 6497827 CA*F4961*6D*+TXV G*VC81005C*B* 48,000 36,400 17.00 12.20 1,520 6497834 CA*F4961*6D*+TXV A*VM961155DXB* 47,500 36,200 18.00 13.00 1,600 6497832 CA*F4961*6D*+TXV ADVC81005C*B* 48,000 36,400 17.00 12.20 1,550 6497833 CA*F4961*6D*+TXV A*VC81005C*B* 48,000 36,400 17.00 12.20 1,520 6497826 CA*F4961*6D*+TXV A*VC950905DXB* 47,000 35,800 17.50 13.00 1,750 6497828 CA*F4961*6D*+TXV A*VC951155DXB* 47,500 36,200 18.00 13.00 1,600 6497829 CA*F4961*6D*+TXV A*VM960805DXB* 47,000 35,800 17.50 13.00 1,750 6497830 CA*F4961*6D*+TXV A*VM961005DXB* 47,500 36,200 18.00 13.00 1,600 6497831 CA*F4961*6D*+TXV A*VC80805C*B* 48,000 36,400 17.00 12.80 1,590 5038944 CHPF4860D6D*+EEP+TXV 48,000 36,400 15.50 12.50 1,500 5357215 CHPF4860D6D*+MBVC1600**-1A*+TXV 46,000 35,000 17.00 13.00 1,725 3654393 CHPF4860D6D*+MBVC2000**-1A*+TXV 47,500 36,200 18.00 13.25 1,750 3654394 CHPF4860D6D*+TXV G*VC80805C*B* 48,000 36,400 17.00 12.80 1,590 5039018 CHPF4860D6D*+TXV A*VC80805C*B* 48,000 36,400 17.00 12.80 1,590 5038820 CHPF4860D6D*+TXV G*VC951155DXB* 47,500 36,200 18.00 13.00 1,600 5620913 CHPF4860D6D*+TXV A*VM960604CXB* 46,000 35,000 17.00 13.00 1,725 5620916 CHPF4860D6D*+TXV G*VM960805CXB* 47,000 35,800 16.50 13.00 1,750 5620918 CHPF4860D6D*+TXV G*VM960604CXB* 46,000 35,000 17.00 13.00 1,725 5620917 CHPF4860D6D*+TXV G*VM961005DXB* 47,500 36,200 18.00 13.00 1,600 5620922 CHPF4860D6D*+TXV G*VC950905CXB* 47,000 35,800 16.50 13.00 1,750 5620907 CHPF4860D6D*+TXV G*VM961155DXB* 47,500 36,200 18.00 13.00 1,600 5620924 CHPF4860D6D*+TXV G*VM960805DXB* 47,000 35,800 17.50 13.00 1,750 5620920 CHPF4860D6D*+TXV A*VC81005C*B* 48,000 36,400 17.00 12.20 1,520 6497835 CHPF4860D6D*+TXV A*VC951155DXB* 47,500 36,200 18.00 13.00 1,600 6497838 CHPF4860D6D*+TXV A*VM960805DXB* 47,000 35,800 16.50 13.00 1,750 6497840 CHPF4860D6D*+TXV G*VC81005C*B* 48,000 36,400 17.00 12.20 1,520 6497843 CHPF4860D6D*+TXV A*VM960805CXB* 47,000 35,800 16.50 13.00 1,750 6497839 CHPF4860D6D*+TXV A*VM961005DXB* 47,500 36,200 18.00 13.00 1,600 6497841 CHPF4860D6D*+TXV A*VM961155DXB* 47,500 36,200 18.00 13.00 1,600 6497842 CHPF4860D6D*+TXV A*VC950905DXB* 47,000 35,800 17.50 13.00 1,750 6497837 CHPF4860D6D*+TXV G*VC950905DXB* 47,000 35,800 17.50 13.00 1,750 5620909 CHPF4860D6D*+TXV A*VC950905CXB* 47,000 35,800 16.50 13.00 1,750 6497836 CSCF4860N6D*+EEP+TXV 48,000 36,400 15.50 12.50 1,500 5357216

DSXC18 0481A*

See Notes on Page 21.

Page 21 of the Goodmans Air Conditioner (DSXC18) user manual — DSXC18 0601A*
Pagina 21 · clicca per ingrandire
Pagina 21

AHRI R atings ( cont .)

Indoor Units Cooling Ratings CFM AHRI # Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³

AVPTC60D14A* 58,000 42,000 16.00 11.75 1,780 5924370 CA*F4961*6D*+EEP+TXV 57,000 41,000 15.00 12.00 1,500 5357217 CA*F4961*6D*+MBVC2000**-1A*+TXV 58,000 42,000 17.00 12.00 2,000 4431669 CA*F4961*6D*+TXV A*VC950915DXB* 58,000 42,000 16.00 11.50 1,750 5620929 CA*F4961*6D*+TXV G*VC950915DXB* 58,000 42,000 16.00 11.50 1,750 5620930 CA*F4961*6D*+TXV G*VM960805DXB* 58,000 42,000 16.00 11.50 1,750 5620935 CA*F4961*6D*+TXV G*VM960805CXB* 58,000 42,000 16.00 11.50 1,750 5620933 CA*F4961*6D*+TXV G*VM961005DXB* 58,000 42,000 16.00 11.50 1,900 5620937 CA*F4961*6D*+TXV G*VC950905CXB* 58,000 42,000 16.00 11.50 1,750 5620925 CA*F4961*6D*+TXV G*VC950905DXB* 58,000 42,000 16.00 11.50 1,750 5620927 CA*F4961*6D*+TXV G*VC951155DXB* 58,000 42,000 16.00 11.50 1,900 5620931 CA*F4961*6D*+TXV G*VC80805C*B* 56,000 40,500 16.00 11.20 1,890 6484852 CA*F4961*6D*+TXV G*VC81005C*B* 56,000 40,500 16.00 11.20 1,800 6484853 CA*F4961*6D*+TXV A*VC81005C*B* 56,000 40,500 16.00 11.20 1,800 6484851 CA*F4961*6D*+TXV A*VM960805CXB* 58,000 42,000 16.00 11.50 1,750 6497847 CA*F4961*6D*+TXV ADVC80805C*B* 56,000 40,500 16.00 11.20 1,940 6497850 CA*F4961*6D*+TXV ADVC81005C*B* 56,000 40,500 16.00 11.20 1,820 6497851 CA*F4961*6D*+TXV A*VC950905DXB* 58,000 42,000 16.00 11.50 1,750 6497845 CA*F4961*6D*+TXV A*VM961005DXB* 58,000 42,000 16.00 11.50 1,900 6497848 CA*F4961*6D*+TXV A*VC951155DXB* 58,000 42,000 16.00 11.50 1,900 6497846 CA*F4961*6D*+TXV A*VM961155DXB* 58,000 42,000 16.00 11.50 1,900 6497849 CA*F4961*6D*+TXV G*VM961155DXB* 58,000 42,000 16.00 11.50 1,900 5620939 CA*F4961*6D*+TXV A*VC80805C*B* 56,000 40,500 16.00 11.20 1,890 6484850 CA*F4961*6D*+TXV A*VC950905CXB* 58,000 42,000 16.00 11.50 1,750 6497844 CHPF4860D6D*+EEP+TXV 57,000 41,000 15.00 12.00 1,500 5357218 CHPF4860D6D*+MBVC2000**-1A*+TXV 58,000 42,000 17.00 12.00 2,000 3654439 CHPF4860D6D*+TXV G*VC951155DXB* 58,000 42,000 16.00 11.75 1,750 5620932 CHPF4860D6D*+TXV G*VC950905DXB* 58,000 42,000 16.00 11.50 1,900 5620928 CHPF4860D6D*+TXV G*VM960805CXB* 58,000 42,000 16.00 11.50 1,900 5620934 CHPF4860D6D*+TXV G*VM961005DXB* 58,000 42,000 16.00 11.75 1,750 5620938 CHPF4860D6D*+TXV G*VM961155DXB* 58,000 42,000 16.00 11.75 1,750 5620940 CHPF4860D6D*+TXV G*VM960805DXB* 58,000 42,000 16.00 11.50 1,900 5620936 CHPF4860D6D*+TXV G*VC80805C*B* 56,000 40,500 16.00 11.20 1,890 6484856 CHPF4860D6D*+TXV A*VC80805C*B* 56,000 40,500 16.00 11.20 1,890 6484854 CHPF4860D6D*+TXV G*VC81005C*B* 56,000 40,500 16.00 11.20 1,800 6484857 CHPF4860D6D*+TXV A*VC950905CXB* 58,000 42,000 16.00 11.50 1,900 6497852 CHPF4860D6D*+TXV A*VM960805DXB* 58,000 42,000 16.00 11.50 1,900 6497856 CHPF4860D6D*+TXV A*VC951155DXB* 58,000 42,000 16.00 11.75 1,750 6497854 CHPF4860D6D*+TXV A*VC950905DXB* 58,000 42,000 16.00 11.50 1,900 6497853 CHPF4860D6D*+TXV A*VM960805CXB* 58,000 42,000 16.00 11.50 1,900 6497855 CHPF4860D6D*+TXV A*VM961005DXB* 58,000 42,000 16.00 11.75 1,750 6497857 CHPF4860D6D*+TXV A*VM961155DXB* 58,000 42,000 16.00 11.75 1,750 6497858 CHPF4860D6D*+TXV G*VC950905CXB* 58,000 42,000 16.00 11.50 1,900 5620926 CHPF4860D6D*+TXV A*VC81005C*B* 56,000 40,500 16.00 11.20 1,800 6484855 CSCF4860N6D*+EEP+TXV 57,000 41,000 15.00 12.00 1,500 5357219

DSXC18 0601A*

¹ BTU/h ² Seasonal Energy Efficiency Ratio; Certified per AHRI 210/240 @ 80°F/ 67°F/ 95°F ³ Energy Efficiency Ratio @ 80°F/ 67°F/ 95°F

  • Notes
  • Always check the S&R plate for electrical data on the unit being installed.
  • When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit.
  • EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay
Page 22 of the Goodmans Air Conditioner (DSXC18) user manual — Model W D H
Pagina 22 · clicca per ingrandire
Pagina 22

D imensions

Goodmans Air Conditioner (DSXC18) — D imensions diagram (page 22)
Fig. 5 · D imensions

Model W D H

DSXC180361A* 35½ 35½ 38¼

DSXC180481A* 35½ 35½ 38¼

DSXC180601A* 35½ 35½ 38¼

Page 23 of the Goodmans Air Conditioner (DSXC18) user manual — W iring D iagram
Pagina 23 · clicca per ingrandire
Pagina 23

W iring D iagram

Goodmans Air Conditioner (DSXC18) — W iring D iagram diagram (page 23)
Fig. 6 · W iring D iagram
1. IF DT IS NOT PRESENT, HPS BL/PK WIRE GOES DIRECTLY TO TERMINAL E29.

THE FACTORY. THE WIRES GO TO INDOOR T-STAT AS SHOWN

2. USE COPPER SUPPLY WIRES ONLY. 3. USE 40VA TRANSFORMER MINIMUM.

IN "LEGACY INDOOR T-STAT". TO WIRE THE SYSTEM IN

sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡

unit for the most up-to-date wiring. ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power

Wiring is subject to change. Always

refer to the wiring diagram or the

Page 24 of the Goodmans Air Conditioner (DSXC18) user manual — A ccessories
Pagina 24 · clicca per ingrandire
Pagina 24

A ccessories

Goodmans Air Conditioner (DSXC18) — A ccessories diagram (page 24)
Fig. 7 · A ccessories

◊ Contains 20 brackets; four brackets needed to anchor unit to pad ¹ This component is included in the CTK01AA communicating thermostat kit. ² Installed on indoor coil ³ Available in 24V legacy mode only. This feature is integrated in the communicating mode. ⁴ Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when

used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. The TXV should always be sized based on the tonnage of the outdoor unit.

  • Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2013
  • Goodman Manufacturing Company, L.P.
  • Houston, Texas
  • Printed in the USA.
Fonti

Riferimenti e link

Pagine di riferimento in questo manuale: produttore, supporto e download.

Fai una domanda su Goodmans Air Conditioner (DSXC18)

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Goodmans Air Conditioner (DSXC18)

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Goodmans Air Conditioner (DSXC18) manuale in PDF

24 pagine·635 KB·Climatizzatore·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…