TECHNICAL MANU AL This manual should remain with the unit. R-200A Digital Contr oller A ne w standar d of reliability.
IM PORT ANT SAFETY INSTRUCTIONS R-panel T echnical Manual SA VE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted in potential hazard areas. Safety should be stressed to all operators and potential operators of this equipment.
T able of Contents R-panel T echnical Manual 1 Safety Rules ........................................ Inside Front Cover General Information ......................................................... 2 Introduction ......................................
I NTRODUCTION The R-200A Controller incorporates the generator control circuitry , the ignition coil driver circuitry and the interface circuitry to an external governor driver . The R-200A Controller can control a; 4- cylinder , 1.6L, 1800 rpm or 3600 rpm engine 4- cylinder , 2.
3 Jumper JMP1/S2: Selects the engine displacement. Set to position 1 and 2 for 1.6L. Set to position 2 and 3 for 2.4L. The jumper is not used on PCB's 0G1505A or 0G1505B. On later revisions, JMP1 is replaced by S2. S2 has no effect on 4.2L operation and is ignored when DIP Switch P osition 7 is ON .
4 General Information R-panel T echnical Manual Switch P osition Condition System Low Low Low High Over Over Manual A uto Off Ready Fuel Bat Oil T emp Speed Crank Generator Switch is OFF @ X OFF OFF O.
5 GEN ERA T OR OP ERA TION The R-200A controller monitors the front panel switch position and reads the DIP switch position set - tings when the control board is initially powered-up. In the OFF position the controller will only be incre - menting the exercise timer and monitoring the bat - tery voltage and low fuel pressure sensor .
6 General Information R-panel T echnical Manual A CTIVE AL ARM Low Oil Pressure, High Coolant T emp, Low Coolant Level, Overspeed, Overcrank, Engine Speed Signal Loss and a Dead Battery indication will all be latched shutdowns.
7 D ANGER With the switch set to AUTO, the engine can crank and start suddenly without warning. Such automatic start up normally occurs when utility source voltage dr ops below a pre-set level.
8 R PM SIGNAL F AI L U R E (F LASHI NG R ED O VERSP EED IN DICA T OR) If the R-200A controller does not receive a signal from the engine flywheel sensor , the R-200A control- ler cannot maintain the generator output frequency or monitor for an overspeed condition.
9 Be very careful when connecting high-voltage wires labeled N1 and N2 and low-voltage wir es labeled 23 and 194 in both the generator wiring panel and the transfer switch wiring panel. The control boar d will be damaged if these wires are not connected correctly .
10 Route the 2-wire start control wires through suit - able, approved conduit which is separate from the AC power leads. Connection of wire 178 to wire 183 by relay contact closure action (volt free switch con- tacts) in the transfer switch must result in generator engine cranking and startup (see Figure 5).
11 R-200A J1 C ON NECT OR (23 PI N, GRA Y=1 800 R PM, WH ITE=3 600 R P M) Pin # 1 Governor 12V Supply 2 Reserved (Do not connect any wires to this pin.
12 D ANGER Storage batteries give off explosive hydr ogen gas. This gas can form an explosive mixture around the battery for several hours after charg- ing. The slightest spark can ignite the gas and cause an explosion. Such an explosion can shat- ter the battery and cause blindness or other injury .
13 Notes R-panel T echnical Manual.
Part No. 0G1341 GENERAC ® POWER SY STEMS, INC. P .O. BOX 8 W AUKESHA, WI 53187 Revision E (06/19/07) Printed in U.S.A..
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Generac Power Systems R-200A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Generac Power Systems R-200A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Generac Power Systems R-200A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Generac Power Systems R-200A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Generac Power Systems R-200A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Generac Power Systems R-200A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Generac Power Systems R-200A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Generac Power Systems R-200A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.