DEADLY EXHAUST FUMES! ONLY use OUTSIDE far away from windows, doors and vents!
NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS.
SAVE this Manual. Provide this manual to any operator of the generator.


INTRODUCTION Thank you for purchasing this model by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available or in place of utility due to a power outage.
SAFETY RULES Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows:
READ THIS MANUAL THOROUGHLY If any portion of this manual is not understood, contact the nearest Authorized Dealer for starting, operating and servicing procedures.
INDICATES A HAZARDOUS SITUATION OR ACTION WHICH, IF NOT AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.
The operator is responsible for proper and safe use of the equipment. We strongly recommend that the operator read this manual and thoroughly understand all instructions before using the equipment. We also strongly recommend instructing other users to properly start and operate the unit. This prepares them if they need to operate the equipment in an emergency.
Indicates a hazardous situation or action which, if not avoided, could result in death or serious injury.
The generator can operate safely, efficiently and reliably only if it is properly located, operated and maintained. Before operating or servicing the generator:
Indicates a hazardous situation or action which, if not avoided, could result in minor or moderate injury.
These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the action or service are essential to preventing accidents.
Four commonly used safety symbols accompany the DANGER, WARNING and CAUTION blocks. The type of information each indicates is as follows:
This symbol points out important safety information that, if not followed, could endanger personal safety and/or property of others.
THE INFORMATION CONTAINED HEREIN WAS BASED ON MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION. GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT ANY TIME.
This symbol points out potential explosion hazard.
For any Frequently Asked Questions (FAQs) for your product, please go to: http://www.generac.com/service-support/faqs
This symbol points out potential fire hazard.
This symbol points out potential electrical shock hazard.

EXHAUST & LOCATION HAZARDS
This generator is equipped with a spark arrestor muffler. The spark arrestor must be maintained in effective working order by the owner/ operator. In the State of California, a spark arrestor is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands.

1. National Fire Protection Association (NFPA) 70: The NATIONAL ELECTRIC CODE (NEC) available from www.nfpa.org 2. National Fire Protection Association (NFPA) 5000: BUILDING CONSTRUCTION AND SAFETY CODE available from www. nfpa.org 3. International Building Code available from www.iccsafe.org 4. Agricultural Wiring Handbook available from www.rerc.org Rural Electricity Resource Council P.O. Box 309 Wilmington, OH 45177-0309 5. ASAE EP-364.2 Installation and Maintenance of Farm Standby Electric Power available from www.asabe.org American Society of Agricultural & Biological Engineers 2950 Niles Road, St. Joseph, MI 49085 This list is not all inclusive. Check with the Authority Having Local Jurisdiction (AHJ) for any local codes or standards which may be applicable to your jurisdiction.
SERIAL NO:
Unit ID Location


1.1 UNPACKING

Check all contents. If any parts are missing or damaged, locate an authorized dealer at 1-888-436-3722.
1.2 ASSEMBLY The generator requires some assembly prior to using it. If problems arise when assembling the generator, please call the Generator Helpline at 1-888-436-3722.

The wheels are designed to greatly improve the portability of the generator.
The wheels are not intended for over-the-road-use.
2.1 KNOW THE GENERATOR Read the Owner’s Manual and Safety Rules before operating this generator.
Compare the generator to Figures 3 through 6 to become familiarized with the locations of various controls and adjustments. Save this manual for future reference.

3. Air Filter – Filters intake air as it is drawn into the engine. 4. Choke Knob – Used when starting a cold engine. 5. Fuel Tank – Tank holds 4 U.S. gallons of fuel. 6. Grounding Lug – Ground the generator to an approved earth ground here. See "Grounding the Generator" for details. 7. ON/OFF Switch – Controls the operation of the generator. 8. Muffler – Quiets the engine. 9. Handle – Pivot and retract for storage. 10. Gas Cap – Fuel fill location. 11. Fuel Gauge – Shows fuel level in tank. 12. Oil Check/Fill – Check and fill oil here. 13. Recoil Starter – Use to start engine manually. 14. Fuel Shut Off – Valve between fuel tank and carburetor. 15. Oil Drain Plug – Used to drain engine oil. 16. Spark Arrestor – Reduces fire hazard by containing sparks. 17. Roll Over Valve – Passes fuel vapors to the carbon canister. 18. Carbon Canister – Absorbs fuel tank vapors. 19. Recovery Hose – Installed between items 17 & 18.

Figure 6 - Generator Controls




This generator has an equipment ground that connects the generator frame components to the ground terminals on the AC output receptacles (see NEC 250.34 (A) for explanation). This allows the generator to be used as a portable without grounding the frame of the generator as specified in NEC 250.34.
This is a 120 Volt outlet protected against overload by a 13.5 Amp push-to-reset circuit breaker (Figure 6). 13.5 Amps of current may be drawn from each socket, however, total power drawn must be kept within data plate ratings. Use only high quality, well insulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or greater).
There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator.
2.3 HOW TO USE THE GENERATOR If there are any problems operating the generator, please call the generator helpline at 1-888-436-3722.
Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction:
In some areas, generators are required to be registered with local utility companies.
Never operate in an enclosed area or indoors! NEVER use in the home, in a vehicle, or in partly enclosed areas such as garages, EVEN IF doors and windows are open! ONLY use outdoors and far from open windows, doors, vents, and in an area that will not accumulate deadly exhaust.
If the generator is used at a construction site, there may be additional regulations which must be observed.
The engine exhaust fumes contain carbon monoxide, which you cannot see or smell. This poisonous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death.
When connecting directly to a building’s electrical system, it is recommended that a manual transfer switch is used. Connections for a portable generator to a building’s electrical system must be made by a qualified electrician and in strict compliance with all national and local electrical codes and laws.
Adequate, unobstructed flow of cooling and ventilating air is critical to correct generator operation. Do not alter the installation or permit even partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator. The generator MUST be operated outdoors.

This exhaust system must be properly maintained. Do nothing that might render the exhaust system unsafe or in noncompliance with any local codes and/or standards.
Always use a battery operated carbon monoxide alarm indoors, installed according to the manufacturers instructions.

DO NOT connect 240 Volt loads to 120 Volt receptacles. DO NOT connect 3-phase loads to the generator. DO NOT connect 50 Hz loads to the generator.

2.4 DON’T OVERLOAD THE GENERATOR Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected electrical devices. Observe the following to prevent overloading the unit:
Iron 1200 *Jet Pump 800 Lawn Mower 1200 Light Bulb 100 Microwave Oven 700 to 1000 *Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater (140,000 Btu) 400 Oil Fired Space Heater (85,000 Btu) 225 Oil Fired Space Heater (30,000 Btu) 150 *Paint Sprayer, Airless (1/3 HP) 600 Paint Sprayer, Airless (handheld) 150 Radio 50 to 200 *Refrigerator 700 Slow Cooker 200 *Submersible Pump (1-1/2 HP) 2800 *Submersible Pump (1 HP) 2000 *Submersible Pump (1/2 HP) 1500 *Sump Pump 800 to 1050 *Table Saw (10") 1750 to 2000 Television 200 to 500 Toaster 1000 to 1650 Weed Trimmer 500 * Allow 3 times the listed watts for starting these devices.
2.6 BEFORE STARTING THE GENERATOR Prior to operating the generator, engine oil and gasoline will need to be added, as follows:
2.5 WATTAGE REFERENCE GUIDE Device Running Watts *Air Conditioner (12,000 Btu) 1700 *Air Conditioner (24,000 Btu) 3800 *Air Conditioner (40,000 Btu) 6000 Battery Charger (20 Amp) 500 Belt Sander (3") 1000 Chain Saw 1200 Circular Saw (6-1/2") 800 to 1000 *Clothes Dryer (Electric) 5750 *Clothes Dryer (Gas) 700 *Clothes Washer 1150 Coffee Maker 1750 *Compressor (1 HP) 2000 *Compressor (3/4 HP) 1800 *Compressor (1/2 HP) 1400 Curling Iron 700 *Dehumidifier 650 Disc Sander (9") 1200 Edge Trimmer 500 Electric Blanket 400 Electric Nail Gun 1200 Electric Range (per element) 1500 Electric Skillet 1250 *Freezer 700 *Furnace Fan (3/5 HP) 875 *Garage Door Opener 500 to 750 Hair Dryer 1200 Hand Drill 250 to 1100 Hedge Trimmer 450 Impact Wrench 500
All oil should meet minimum American Petroleum Institute (API) Service Class SJ, SL or better. Use no special additives. Select the oil's viscosity grade according to the expected operating temperature (also see chart).

Any attempt to crank or start the engine before it has been properly serviced with the recommended oil may result in an engine failure.

1. Place generator on a level surface (not to exceed 15° in any direction). 2. Clean area around oil fill and remove oil fill cap and dipstick. 3. Wipe dipstick clean. 4. Slowly fill engine with oil through the oil fill opening until it reaches the full mark on the dipstick. Stop filling occasionally to check oil level. Be careful not to over fill. 5. Install oil fill cap and finger tighten securely. 6. Check engine oil level before starting each time thereafter.
IMPORTANT: It is important to prevent gum deposits from forming in fuel system parts such as the carburetor, fuel hose or tank during storage. Alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See the "Storage" section. Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.
Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Allow engine to cool entirely before filling fuel tank. Avoid spilling gasoline on HOT engine. DO NOT light a cigarette or smoke when filling the fuel tank. Gasoline is highly flammable and its vapors are explosive.
Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on. 1. Unplug all electrical loads from the unit's receptacles before starting the engine. 2. Make sure the unit is in a level position (not to exceed 15° in any direction). 3. Turn the Fuel Shut-off Valve to the "ON" position (Figure 9). 4. Turn engine ON/OFF switch to ON position (Figure 9). 5. Move engine CHOKE lever to the START position (Figure 10). 6. To start engine, firmly grasp the recoil handle and pull slowly until increased resistance is felt. Pull rapidly up and away. 7. When engine starts, move choke lever to 1/2-CHOKE position until engine runs smoothly and then fully into RUN position. If engine falters, move choke back out to 1/2-CHOKE position until engine runs smoothly and then to RUN position.
Do not overfill the fuel tank. Always leave room for fuel expansion. If the fuel tank is overfilled, fuel can overflow onto a HOT engine and cause FIRE or EXPLOSION. 1. Use regular UNLEADED gasoline with the generator engine. Do not use any gasoline with more than 10% added Ethanol, and never use E85 gasoline. Do not mix oil with gasoline. 2. Clean area around fuel fill cap, remove cap. 3. Slowly add unleaded regular gasoline to fuel tank. Be careful not to overfill (Figure 8). 4. Install fuel cap and wipe up any spilled gasoline.
If engine fires, but does not continue to run, move choke lever to the START position and repeat starting instructions.
Figure 9 - Fuel Shut-off Valve


FUEL SHUT-OFF
VALVE
RECOIL HANDLE
ON/OFF SWITCH

3.1 MAINTENANCE SCHEDULE Follow the calendar intervals. More frequent service is required when operating in adverse conditions noted below.

Check Oil Level At Each Use Change Oil + *Every Season Check Valve Clearance ***Every Season Service Air Filter **Every Season Replace Spark Plug Every Season + Change oil after first 20 hours of operation, then every season. * Change oil every month when operating under heavy load or in high temperatures. ** Clean more often under dirty or dusty operating conditions. Replace air filter parts if they cannot be adequately cleaned. *** Check valve clearance and adjust if necessary after first 50 hours of operation and every 100 hours thereafter.
Rated. Power 3.25 kW** Surge Power 3.75 kW Rated AC Voltage 120 Rated Current 27 Amps** Rated Frequency 60 Hz @ 3600 RPM Phase Single Phase
** Maximum wattage is subject to, and limited by, such factors as fuel Btu content, ambient temperature, altitude, engine condition, etc.. Maximum power decreases about 3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 10 °F (6 °C) above 60 °F (16 °C) ambient temperature.
2.8 STOPPING THE ENGINE 1. Shut off all loads, then unplug the electrical loads from generator panel receptacles. Never start or stop the engine with electrical devices plugged in and turned on. 2. Let engine run at no-load for several minutes to stabilize the internal temperatures of engine and generator. 3. Move ON/OFF switch to OFF position. 4. Close fuel valve.
Displacement 208 cc Spark Plug Type F6TC, NGK BPR4ES or Champion RN14YC Spark Plug Gap 0.028-0.031 inch or (0.70-0.80 mm) Gasoline Capacity 4 U.S. gallons (15.14 L) Oil Type See Chart in "Before Starting the Generator" Section Oil Capacity 0.634 Qts. (0.6 L) Run Time 12.5 Hours at 1/2 Load Operating Temperature Range 0 °F (-17 °C) to 110 °F (43 °C)*
2.9 LOW OIL LEVEL SHUTDOWN SYSTEM The engine is equipped with a low oil level sensor that shuts down the engine automatically when the oil level drops below a specified level. If the engine shuts down by itself and the fuel tank has enough gasoline, check engine oil level.
* When operating above 77 °F (25 °C) there may be a decrease in power.
If the system senses a low oil level during operation, the engine shuts down. The engine will not run until the oil has been refilled to the proper level.

3.3 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.
See the “Before Starting the Generator” section for information on checking the oil level. The oil level should be checked before each use, or at least every eight hours of operation. Keep the oil level maintained (Figure 11).
Some adjustments will need to be made periodically to properly maintain the generator.
All adjustments in the Maintenance section of this manual should be made at least once each season. Follow the requirements in the "Maintenance Schedule".

Once a year replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help the engine run better and last longer.
3.3.1 GENERATOR MAINTENANCE
Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior surface.
Change the oil after the first 20 hours of operation, then every season. If running this unit under dirty or dusty conditions, or in extremely hot weather, change the oil more often.
Never insert any object or tool through the air cooling slots, even if the engine is not running.
Hot oil may cause burns. Allow engine to cool before draining oil. Avoid prolonged or repeated skin exposure with used oil. Thoroughly wash exposed areas with soap. Use the following instructions to change the oil after the engine cools down:
DO NOT use a garden hose to clean generator. Water can enter the engine fuel system and cause problems. In addition, if water enters the generator through cooling air slots, some water will be retained in voids and crevices of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
When working on the generator, always disconnect spark plug wire from spark plug and keep wire away from spark plug.

Figure 13 - Air Filter
Use spark plug F6TC, NGK BPR4ES or Champion RN14YC. Replace the plug once each year. This will help the engine start easier and run better.


After the first 50 hours of operation, check the valve clearance in the engine and adjust if necessary.
3.6 GENERAL The generator should be started at least once every 30 days and be allowed to run at least 30 minutes. If this cannot be done and the unit must be stored for more than 30 days, use the following information as a guide to prepare it for storage.
3.4 SERVICE AIR FILTER The engine will not run properly and may be damaged if using a dirty air filter. Clean the air filter once a year (Figure 13). Clean or replace more often if operating under dusty conditions.
NEVER store engine with fuel in tank indoors or in enclosed, poorly ventilated areas where fumes may reach an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliance.
Air Cleaner Cover · Air Filter

3.7 LONG TERM STORAGE It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor, fuel hose or tank during storage. Also, experience indicates that alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage.
To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer, as follows:
Drain fuel into approved container outdoors, away from open flame. Be sure engine is cool. Do not smoke. 2. Start and run engine until engine stops from lack of fuel. 3. Drain oil from crankcase after the engine cools down. Refill with recommended grade. 4. Remove the spark plug and pour about 1/2 oz (15 ml) of engine oil into the cylinder. Cover spark plug hole with rag. Pull the recoil starter a couple times to lubricate the piston rings and cylinder bore.
NEVER cover the generator while engine and exhaust areas are warm.
Avoid spray from spark plug hole when cranking engine. 5. Install and tighten spark plugs. Do not connect spark plug wire. 6. Clean the generator outer surfaces. Check that cooling air slots and openings on generator are open and unobstructed. 7. Store the unit in a clean, dry place

4.1 TROUBLESHOOTING GUIDE
Engine is running, but no AC output is available.
Engine runs well but bogs down when loads are connected.
Engine will not start; or starts and runs rough.
Engine shuts down during operation.
Engine lacks power. 1. Load is too high. 2. Dirty air filter. 3. Engine needs to be serviced.
Engine “hunts” or falters. 1. Choke is opened too soon.

Manual Part No. 0H2379 Rev E (09/04/14) Printed in China
Pagine di riferimento in questo manuale: produttore, supporto e download.
Problemi comuni, cause probabili e soluzioni.
| Problema | Possibile causa | Soluzione | |
|---|---|---|---|
| 12 | p.14 | ||
| Engine is running, but no AC output is available. | 1. Circuit breaker is open. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator. 5. 120V GFCI tripped (no light). | 1. Reset circuit breaker. 2. Check and repair. 3. Connect another device that is in good condition. 4. Contact Authorized Service Facility. 5. Reset 120V GFCI push button (light is on). | p.15 |
| Engine is running, but no AC output is available. | p.15 | ||
| Engine runs well but bogs down when loads are connected. | 1. Short circuit in a connected load. 2. Generator is overloaded. 3. Engine speed is too slow. 4. Shorted generator circuit. | 1. Disconnect shorted electrical load. 2. See “Don’t Overload the Generator”. 3. Contact Authorized Service Facility. 4. Contact Authorized Service Facility. | p.15 |
| Engine runs well but bogs down when loads are connected. | p.15 | ||
| Engine will not start; or starts and runs rough. | 1. Dirty air filter. 2. Out of gasoline. 3. Stale gasoline. 4. Spark plug wire not connected to spark plug. 5. Bad spark plug. 6. Water in gasoline. 7. Over-choking. 8. Low oil level. 9. Excessive rich fuel mixture. 10. Intake valve stuck open or closed. 11. Engine has lost compression. | 1. Clean or replace air filter. 2. Fill fuel tank. 3. Drain fuel tank and fill with fresh fuel. 4. Connect wire to spark plug. 5. Replace spark plug. 6. Drain fuel tank; fill with fresh fuel. 7. Put choke knob to No Choke position. 8. Fill crankcase to proper level. 9. Contact Authorized Service Facility. 10. Contact Authorized Service Facility. 11. Contact Authorized Service Facility. | p.15 |
| Engine will not start; or starts and runs rough. | p.15 | ||
| Engine shuts down during operation. | 1. Out of gasoline. 2. Low oil level. 3. Fault in engine. | 1. Fill fuel tank. 2. Fill crankcase to proper level. 3. Contact Authorized Service Facility. | p.15 |
| Engine shuts down during operation. | p.15 | ||
| Engine lacks power. | 1. Load is too high. 2. Dirty air filter. 3. Engine needs to be serviced. | 1. See “Don’t Overload the Generator”. 2. Replace air filter. 3. Contact Authorized Service Facility. | p.15 |
| Engine lacks power. | p.15 | ||
| Engine “hunts” or falters. | 1. Choke is opened too soon. 2. Carburetor is running too rich or too lean. | 1. Move choke to halfway position until engine runs smoothly. 2. Contact Authorized Service Facility. | p.15 |
| Engine “hunts” or falters. | p.15 |