Clar it y II T56 T urbidimet er T56 Instruction Manual P N 51- T56 May 2012.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 This page l eft blank intentionally.
Clar it y II T56 T urbidimet er ESSENTI AL INSTRUC TIONS -Read this p age before proceeding! Y our instrumen t purcha se from Ro semo unt Analy tical, Inc. is one of the finest availab le for your par ticular applicatio n. These instrume nts hav e been designed, and tested to meet many natio nal and intern ationa l standar ds.
This produc t genera tes, uses, and can radiate radio frequency ener gy and thus can cause radio communication interfere nce. Improper inst allation , or operati on, may increa se such interfere nce.
C on te nts Section 1: Description and Specifications 1 .1 F e atures and Applica tions ......................................................................................1 1.2 Specifi cations – Ge neral ..........................................
ii T able of C onte nts c ont’d Section 6: Programming - T urbidity 6.1 Programming Me asure ments – In troduc tion .......................................................23 6.2 T urbidit y Measu reme nt Programming ...............................
Sec tion 1: Des crip tion and S peci ficati ons 1.1 F eatures and Applications C OMPLETE SYSTEM includes single or dual inpu t analyze r , sensor(s), and de bubbler a sse mbly CHOOSE U .S. EP A METHOD 180.1 or ISO METHOD 7027 compli ant sensors RANGE 0-200 NTU RESOLUTION 0.
1.2 Specifications - General Case: P olycarbon ate . NEMA 4X/CSA 4, IP66. NOTE: T o ensure a NEMA se al, tighte n all four front p anel scr ews to 6 in-lbs o f tor que. Dimensions: 6.2 x 6.2 x 5.2 in. (157 x 157 x 132mm) Conduit openings: A cce pts (6) PG13.
Ordinar y Locations: Pollution Degree 2: Norm ally only non-conductive pollution occ urs. Occasion ally , howe ver , a tem porar y conductivit y caused b y condensa tion must be expected. Altitude : for use u p to 2000 me ter (6562 f t.) RFI/EMI: – EN-61326 L VD: – EN -61010-1 In pu t: O ne o r two i s ol at ed s en so r in pu ts .
4 Descriptio n and Spec ificatio ns Instruction Manual Clarity II T56 PN-51- T56 May 2012 T56 T urbidity System Components C ode S ensor T ype 01 EP A Sensor 02 ISO Se nsor 40 EP A Sensor (Sec ond Sen.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 Sec tion 2.0 – Installa tion 2.1 Unpacking and Inspec tion Th e Cl ar ity II T ur bi di me t er i s a c om pl e t e s ys te m f o r th e de t er mi n at io n o f tu rb id ity in dr in ki n g wa t e r .
6 Installation Instruction Manual Clarity II T56 PN-51- T56 May 2012 Fig. 2-1 T56 Panel Mounting Installation dimensions PA N EL SU PP LIE D B Y OTHERS M A XI M UM THIC KN ESS .375 IN (9.52 mm ) PA NEL MOUNT GA SKET BO T T OM VIEW FRONT VIE W SIDE VIEW PA NEL CUT-OUT 6.
Installation 7 Instruction Manual Clarity II T56 PN-51- T56 May 2012 F ig. 2-2 T56 Pipe and W all Mounting Installation dimensions NOTES : UNLESS OT HERWISE SPE CI FIED L C FRONT PA NEL 2 IN CH P IPE MO UNT BR ACK E T 2X SET U-BOLT S FOR 2 " PIPE IN KIT PN 2382 0-00 1 VERTICA L PIP E MOUN TI NG SHOWN.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 8 Ordering Information 2.3 Installation – Debubbler Assembly See Figu re 2 -3 f or i nstal lat ion. Co nnect the s ampl e li ne to the inl et fit tin g. T he f itt ing ac c e p ts 1/4- in ch OD tub ing .
Installation 9 Instruction Manual Clarity II T56 PN-51- T56 May 2012 F ig. 2-3 Debubbler and Flo w Chamber.
10 Instruction Manual Clarity II T56 PN-51- T56 May 2012 2.4 Installation – Sensor Uns cre w t he n ut o n t he s id e o f t he de bub ble r . I nse r t th e s ens or i n th e m outh of th e me as uring ch amb e r . Be s ure the p in on the de bu bb le r li nes up w ith t he h ole in the s ens or .
Sec tion 3.0 Wiring 3.1 General The T56 is ea sy to wire. It i ncludes r emo vable connectors and slide-out sign al input boar ds. The front pa nel is hinged at the bo ttom.
3.2 Preparing Conduit Openings The re are s ix co ndui t op en ing s in al l con figura tions o f T56. (No te th at four of the ope nings will b e fi tted wi th pl ugs u pon ship ment .) C on dui t o pe nin gs a cc ep t 1/ 2-i nch c ond uit fi tti ng s o r PG1 3.
3.4.4 Se nsor wiring t o signal bo ards Plug the pre-te rminated se nsor cable connector directly into the turbi dit y signal bo ard m ating connector . 3.4.5 Se nsor The sens or cable is pre-wired t o a plug that inse r ts into a rece iving socke t on the signal board .
14 Instruction Manual Clarity II T56 PN-51- T56 May 2012 IMPORT ANT NOTE: When u sing EP A/incandesce nt senso rs (PN 8-0108-0002-EP A): • DO NO T power u p the instrumen t without the se nsor connected • DO NO T disconnect and rec onnect a sensor while an an aly zer i s powe red If this is inc onv enient or cannot be a voided: 1.
Sec tion 4.0 Dis pl ay and Ope ra tion 4.1 User Int er face Th e T56 ha s a l ar ge di spl a y whi ch sho ws two li ve m ea su re me n t re ado uts in l arg e d igi ts and up t o six ad dit ion al pr oc es s var ia ble s o r d ia g- no sti c pa ram et ers c onc urr en tl y .
Th e EN TE R/ ME NU k e y is a ls o u se d t o e nt er s e le cti on s o r e n ab le p ro gr amm in g an d ca li br a ti on s te p s. The EXIT key re turns to the previou s menu leve l. Th e I NF O ke y pr ov ide s d eta ile d i nst ruct io ns and ex pla na ti on s d uri ng pr ogr amm ing an d c ali bra ti ng pr oc edu res .
Instruction Manual Clarity II T56 PN-51- T56 May 2012 Display and Ope ration 17 4.4 Menu System The T 56 me nu system is simil ar to a comput er . Pressing the ENTER/MENU k ey at an y time o pens the t op -level me nu including Calibrati on, Hold, Programming , Displ ay , Data and HAR T functions.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 18 This page l eft blank intentionally.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 Programming Basics 19 S e ct i o n 5 . 0 . Pr o g r a m mi ng t h e A n a lyz e r - Ba s i cs 5.1 General T yp ica l p rog ram min g s te ps i ncl ude th e f ol lo wi ng lis ted pr oc edu res .
5.4 Security Acces s When e ntering the c orrec t acces s code f or the Calibration/Hold security level, the Calibr ation a nd Hold men us are a cce ssible . This allows opera tors or technici ans to pe r form rou tine main te- nanc e. This security leve l does no t allow acc ess to the Program or Di spla y menus.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 Programming Basics 21 T o reset t o factor y defaults, re set calibration d ata only or res et an alog outputs only , access the Re set screen b y pressing ENTER/MENU from the m ain screen.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 22 Programming Basics 5. T o en ter setpoin ts for rel ays, en ter the de sired value for the proc ess mea suremen t or te mpera ture at which to activate a n alarm ev ent and pre ss ENTER/MENU . 6.
Sec tion 6.0 Programming - T urbi dit y 6.1 Programm ing Measurements – Introduction The T56 au toma tically recogniz es each in stalled mea suremen t board upon first power -up and eac h time the analy ze r is powered.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 24 This page l eft blank intentionally.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 Calibration 25 Sec tion 7.0 Calibra tion 7.1 Calibration – Intro duc tion Calibration is the pr oces s of adjustin g or standard izing the an alyzer t o a lab t est or a calibrated labora tor y instrumen t, or standard izing to some known re fere nce.
7.2.1 Slope Calibra tion – T urbidit y This section describes ho w to c onduc t a 2-point calibra tion of the turbi dit y sens or against a use r-p repar ed 20NTU standar d. The calibrati on requires two step s. Fir st, immerse the se nsor in f ilte red water h aving ve r y low turbidity and measure the sens or output.
Sec tion 8.0 Mai n te n anc e 8.1 Ov er view Th e 5 6 A n alyz er u sed in th e C la rity II tu rbi dim et er n eed s l itt le ro uti ne ma int e n anc e . C le an the an al yz er c as e a nd fro nt p ane l by wi pin g i t w ith a c le an so ft c lo th da mpe ne d wit h w at er ON L Y .
NOTE: I f you h ave a dual input ana lyzer , you can re apply power a t this point. The initi al reading from the othe r sensor will be mom en tarily ze ro. Af ter a bout 60 sec onds the reading will reac h its final value . 3. Using a small Phi llips sc rewdrive r , remo ve the t wo screws holdi ng the top fl ange of the se nsor to the body .
Instruction Manual Clarity II T56 PN-51- T56 May 2012 Mainte nance 29 8.3 Debubbler and Measuring C hamber 8.3.1 Cle aning the se nsor 1. T urn off the sample su pply to the de bubbler . 2. Remo ve the sens or and put it in a sa fe plac e. The calibration c up is a good place t o store the sens or .
30 Mainte nance Instruction Manual Clarity II T56 PN-51- T56 May 2012 8.4 List of R eplacement P ar ts LOCA TION IN DESCRIPTION P ART FIGURE 8-4 NUMBER — Re placem ent l amp board as sembly , USEP A.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 Mainte nance 31 Sec tion 9.0 R e turn o f M a te ri al 9.1 General T o expedite the repa ir and return o f instr umen ts, proper comm unication be t ween the cu stome r and the factor y is impor tant.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 32 Append ix Appe ndix This procedur e describes ho w to verify linearity bet ween turbidity and TSS. 1. Collect a sample of the pro ces s liquid-you ma y need 10 L or more if y ou use the Cl arit y II for me asuring turbidity .
Instruction Manual Clarity II T56 PN-51- T56 May 2012 War ranty 33 W ARRANT Y Se lle r warr an ts th at the firm ware will ex ec ut e th e p rogra mmi ng instru c tion s p rovi ded by Se lle r , a nd .
Instruction Manual Clarity II T56 PN-51- T56 May 2012 34 Certific ation.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 Certific ation 35.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 36 This page l eft blank intentionally.
Instruction Manual Clarity II T56 PN-51- T56 May 2012 37 This page l eft blank intentionally.
Credit Cards f or U.S. Purcha ses Only. The right peo ple , the right answe r s, right now . ON-LINE ORDERING NO W AV AILABLE ON OUR WEB SITE Ro semountAn aly tical.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson PN-51-T56 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson PN-51-T56 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson PN-51-T56 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson PN-51-T56 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson PN-51-T56, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson PN-51-T56.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson PN-51-T56. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson PN-51-T56 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.