Manuale d’uso / di manutenzione del prodotto GEF-3GSDI-16416 del fabbricante Gefen
Vai alla pagina of 39
1080P 16x16 3GSDI Matrix GEF-3GSDI-16416 User Manual www.gefenpro.com.
ASKING FOR ASSIST ANCE Rev A3 T echnical Support : T elephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 T echnical Support Hours: 8:00 AM - 5:00 PM Monday - Friday , Paci fi c T ime For 24 / 7 support, see the back of the product for the support number Write T o: Gefen, LLC c/o Customer Service 20600 Nordhoff St Chatsworth, CA 9131 1 www .
CONTENTS 1 Introduction 2 Operation Notes 3 Features 4 Panel Layout 4 Front Panel 5 Front Panel Descriptions 6 Panel Layout 6 Back Panel 7 Back Panel Descriptions 8 Connecting And Operating The 16x16 .
1 Congratulations on your purchase of the 16x16 3GSDI Matrix. Y our complete satisfaction is very important to us. Gefen Gefen delivers innovative, progressive computer and electronics add-on solutions that harness integration, extension, distribution and conversion technologies.
2 READ THESE NOTES BEFORE INST ALLING OR OPERA TING THE 16X16 3GSDI MA TRIX • There is no internal scaling in the 16x16 3GSDI Matrix. All of the attached monitors must be able to display the resolutions output by the source devices.
3 Features • Increases productivity • Supports resolutions up to 1080p, 1920x1200, and 2K. • Front panel control buttons for local switching. • Status LCD (shows routing status) • Serial interface for remote control via a computer or control automation devices supports RS-232 and RS-485 protocols.
4 Front Panel P ANEL LA YOUT 4 5 6 2 1 3.
5 P ANEL DESCRIPTIONS Front Panel 1 LCD Display Displays the current routing status of the Matrix and is also used to manage source routing. 2 Power Switch T urn the power ON or OFF using this switch. 3 Control Buttons These buttons are used to navigate the LCD menu system.
6 P ANEL LA YOUT Back Panel 4 5 8 9 6 1 3 2 7.
7 P ANEL DESCRIPTIONS Back Panel 1 Reference In Connector Connect an external reference to this connector . Bi-level (black burst) and tri- level sync are supported.
8 How to Connect the 16x16 3GSDI Matrix 1. Connect up to 16 3G-SDI source devices to the 3G-SDI inputs on the rear panel of the 16x16 3GSDI Matrix using SDI cables. 2. Connect up to 16 3G-SDI displays to the 3G-SDI outputs on the rear panel of the 16x16 3GSDI Matrix.
9 The Standby Screen The front panel of the 16x16 3GSDI Matrix has a 16 character 2 line LCD display . This display will shows the current routing status of the Matrix and will be used to perform routing commands and other operations.
10 CONNECTING AND OPERA TING THE 16X16 3GSDI MA TRIX Switching between RS-232 and RS-485 Protocols Press the ► button to display the serial interface selection screen: Use the ◄ or ► buttons to switch between RS-232 and RS-485 serial protocols. The current selection is indicated by the cursor .
11 In the example below , TERMINA TION Of f has been selected. The LCD will now show that the RS-485 protocol has been selected, along with the termination- type: Press the Cancel button to return to the Standby Screen.
12 Displaying the Routing Status From the main screen, press the Select button. When the arrow cursor is next to OUTPUT , pressing the ◄ or ► buttons on the front panel will show the current routing state of each input and output. The example below shows that Input 1 is routed to Output 1.
13 IR REMOTE DESCRIPTION RMT -16416IR Remote Control Unit 1 Activity Indicator This LED will be activated momentarily each time a button is pressed. 2 Display and Source Selection Buttons (1 - 16) These buttons are used to select which source is routed to a monitor .
14 Installing the RMT -16416IR Battery 1. Remove the battery cover on the back of the IR Remote Control unit. 2. Insert the included battery into the open battery slot. The positive (+) side of the battery should be facing up. 3. Replace the battery cover .
15 IR REMOTE CONFIGURA TION How to Resolve IR Code Con fl icts In the event that IR commands from other remote controls interfere with the supplied IR Remote Control unit, changing the IR channel on the IR Remote Control unit will fi x the problem. The IR Remote Control unit has a bank of DIP switches used for setting the IR channel.
16 What features are available via the RS-232 serial communications port? The 16x16 3GSDI Matrix can accept commands through the RS-232 serial communications port located on the rear panel. The current RS-232 control features are: • Switching/routing of inputs to outputs without the RMT -16416IR remote control.
17 RS-232 SERIAL CONTROL RS-232 Features RS-232 remote functions are used to control this product’s features. Features include input / output routing and reference signal functions . These features are available only through the use of the serial port.
18 RS-232 SERIAL CONTROL #PRREFT ABLE Function The #PRREFT ABLE function displays the Reference In data table (timings) which are recognized by the 16x16 3GSDI Matrix.
19 RS-232 SERIAL CONTROL #SNETMASK Function The #SNETMASK function speci fi es a new net mask. Syntax: #SNETMASK param1 param2 param3 param4 Parameters: param1 Net mask [0 - 255] param2 Net mask [0 - 255] param3 Net mask [0 - 255] param4 Net mask [0 - 255] Notes: A reboot is required after using this function.
20 RS-232 SERIAL CONTROL #SPORT Function Speci fi es a new port for a Web server . Syntax: #SPORT param1 Parameters: param1 Port [0 - 255] Notes: A reboot is required after using this function. #PRWEBADD Function Prints the current IP con fi guration on the screen.
21 RS-232 SERIAL CONTROL General Functions Function Description #ACTIVEBOLO Enables the boot loader #F ADEF AUL T Sets IP Con fi gurations to default settings #RMTIRADD Set the remote IR channel #RSTIP Sets IP con fi guration to default #ACTIVEBOLO Function The #ACTIVEBOLO function enables the boot loader .
22 RS-232 SERIAL CONTROL #RMTIRADD Function The #RMTIRADD function set the remote IR channel. Syntax: #RMTIRADD param1 Parameters: param1 IR channel [0 - 3] #RSTIP Function Sets IP con fi guration to default (192.168.0.70) Syntax: #RSTIP Parameters: None Notes: This command requires the unit to be rebooted in order to take effect.
23 Commands Command Description M Returns the current routing status of matrix R Routing command S Routes a single input to all outputs M Command The M command displays the current routing status of the matrix. Syntax: m Parameters: None R Command The R command allows speci fi c routing of inputs and outputs.
24 RS-232 SERIAL COMMANDS S Command The S command routes a single input to all 16 3GSDI outputs. Syntax: s param1 Parameters: param1 Input [1 - 16] Notes : Setting param1 to a value of 0 will place the matrix in one-to-one mode . This means that Input 1 will be routed to Output 1, Input 2 will be routed to Output 2, and so on.
25 IP CONTROL The GefenPRO 16x16 3GSDI Matrix supports IP-based control using an integrated Web interface. T o access this feature, an IP address, subnet, gateway , and port number need to be set on the 16x16 3GSDI Matrix ( Default IP: 192.168.0.70 Subnet: 255.
26 IP CONTROL Masking The Masking page is used to hide an output from displaying any video. From this page, all outputs can be set to “Active” or “Mask”. When an output is set to “Active”, it will function normally . When an output is set to “Mask”, it will not output any video.
27 IP CONTROL IP Con fi guration The IP Con fi guration page is used to set the IP settings that will be used to access the Web interface. The following items can be con fi gured from this menu. • IP Address (Default: 192.168.0.70) • Subnet (Default: 255.
28 IP CONTROL Backup / Restore The Backup/Restore page is used to backup and restore complete setup con fi gurations. Note: This feature will be implemented in a future release.
29 FIRMW ARE UPDA TE Firmware Update Procedure T o Begin the update procedure the unit’s Boot Loader must be activated. T o activate the Boot Loader please follow the procedure below: If the unit is already powered on, the following RS-232 command can be used to activate the Boot Loader: 1.
30 FIRMW ARE UPDA TE Follow the on-screen instructions to complete the fi rmware update process: 1. Press [1] on the computer keyboard to begin downloading program to the temporary memory . 2. A message will appear in Hyperterminal: W aiting for the fi le to be sent .
31 W ARNING MESSAGES System Failure In the case of a critical malfunction, the following warning message will be displayed on the Main Display: If the 16x16 3GSDI Matrix is connected to a PC using a t.
32 RACK MOUNT SAFETY INFORMA TION a. Maximum recommended ambient temperature: 45 ˚ C b. Increase the air fl ow to maintain the temperature inside the rack. c. Install the product evenly to avoid mechanical overload. d. Connect an earthing wire between the an earthing stud and the grounding pin on the chassis.
33 Input / Output • SDI (SMPTE 259MI up to 360 Mbps) • HD-SDI (SMPTE 292M up to 1.485 Gbps) • 3G-SDI (SMPTE 424M/425M up to 3.0 Gbps) Supported Formats......................................................All SD, HD, and 3G formats Maximum Resolution.
34 W ARRANTY Gefen warrants the equipment it manufactures to be free from defects in material and workmanship. If equipment fails because of such defects and Gefen is noti fi ed within two (2) years .
35 LICENSING lwIP is licenced under the BSD licence: Copyright (c) 2001-2004 Swedish Institute of Computer Science. All rights reserved. Redistribution and use in source and binary forms, with or without modi fi cation, are permitted provided that the following conditions are met: 1.
Rev A3 Pb 20600 Nordhoff St., Chatsworth CA 91311 1-800-545-6900 818-772-9100 fax: 818-772-9120 www .gefenpro.com support@gefenpro.com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Gefen GEF-3GSDI-16416 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Gefen GEF-3GSDI-16416 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Gefen GEF-3GSDI-16416 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Gefen GEF-3GSDI-16416 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Gefen GEF-3GSDI-16416, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Gefen GEF-3GSDI-16416.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Gefen GEF-3GSDI-16416. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Gefen GEF-3GSDI-16416 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.