Manuale d’uso / di manutenzione del prodotto MB3842 del fabbricante Fujitsu
Vai alla pagina of 19
DS04-27604-2E FUJITSU SEMICONDUCT OR DA T A S H E E T ASSP F or P o wer Supply Applications P o wer Mana g ement 2-c h Switch IC MB3842/MB3845 ■ DESCRIPTION The MB3842/3845 is a power management switch with built-in 2-channel low-on resistance (typ.
2 MB3842/MB3845 ■ PIN ASSIGNMENT 20 19 18 17 16 15 14 13 12 11 GND OC1 OUT1 OUT1 OUT1 OUT2 OUT2 OUT2 OC2 GND 1 2 3 4 5 6 7 8 9 10 EN1, EN1 SS1 CS1 VIN1 VIN1 VIN2 VIN2 CS2 SS2 EN2, EN2 SSOP-20P (FPT-20P-M03) EN Enable CS Current Set OC Over Current EN Enable SS Slow Start The functions of pin 1 and pin 10 diff er on the MB3842 and MB3845.
3 MB3842/MB3845 ■ PIN DESCRIPTION Pin no. Symbol Descriptions 1/10 EN (MB3842) Control signal input pin. Set “H” to tur n s witch on, “L” to turn toff. At 0.8 V or less , the chip is in STBY state and current consumption is less than 1 µ A.
4 MB3842/MB3845 ■ BLOCK DIA GRAM (for 1 c hannel) SS1 EN1 VIN1 OSC1 BGR1 + − COMP FF1 Q S R OC1 OUT1 CS1 + − COMP MB3842 SS1 EN1 VIN1 OSC1 BGR1 + − COMP FF1 Q S R OC1 OUT1 CS1 + − COMP MB384.
5 MB3842/MB3845 ■ ABSOLUTE MAXIMUM RA TINGS W ARNING: Semiconductor de vices can be per manently damaged by application of stress (v oltage, current, temperature , etc.
6 MB3842/MB3845 ■ ELECTRICAL CHARA CTERISTICS (per 1 ch) • MB3842/MB3845 (V IN = 5 V , T a = +25 ° C) • MB3842 (V IN = 5 V , T a = +25 ° C) • MB3845 (V IN = 5 V , T a = +25 ° C) Parameter Symbol Condition Value Unit Min. Typ. Max. Switch resistance R ON I SW =0.
7 MB3842/MB3845 ■ DIA GRAM (Continued) VIN EN EN V OUT I OUT OC SW OFF Overcurrent does not occur SW ON SW ON 5 V Hi Low 5 V 5 V • Normal operation SW ON SW ON SW ON 2.
8 MB3842/MB3845 (Continued) SW ON OFF ON OFF VIN EN EN V OUT I OUT OC 5 V Hi Low 5 V 5 V = 0 V • At o vercurrent detection SW ON Over-temperature corrected Over-temperature occurs SW OFF VIN EN EN V.
9 MB3842/MB3845 ■ TYPICAL CHARA CTERISTICS (Continued) V IN = 5.0 V V IN = 3.3 V V IN = 2.5 V 10 1 0.1 0.01 100 1000 10000 100000 R LIM ( Ω ) I SW (A) •R LIM vs. limit current characteristics V IN = 5.0 V V IN = 3.3 V V IN = 2.5 V 100 10 1 0.1 10 100 1000 10000 100000 C SS (pF) t ON (ms) •C SS vs.
10 MB3842/MB3845 (Continued) (Continued) 150 140 130 120 110 100 90 80 70 60 50 − 60 − 40 − 20 0 20 40 60 80 100 120 at 0.1 A at 0.6 A at 1 A − 40 ° C 25 ° C 100 ° C 150 140 130 120 110 100 90 80 70 60 50 234567 • SW resistance vs. temperature characteristics • T emperature-depended SW resistance vs.
11 MB3842/MB3845 (Continued) (Continued) 5 V 5 V 100 k Ω 2 Ω VIN I SW V SW R LIM GND EN, EN OC OUT SS CS V IL /V IH A 1600 1400 1200 1000 800 600 400 200 0 02 3 4 5 6 1 I SW (mA) 6.2 k (0.1 A) 2 k (0.6 A) V SW (V) Measurement circuit These are the output saturation current characteristics in overcurrent state.
12 MB3842/MB3845 (Continued) • P ower derating c haracteristics Power dissipation P D (W) 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 − 20 0 20 40 60 80 100 1 V / 500 NS 50 k Ω Temperature Ta ( ° C.
13 MB3842/MB3845 ■ FUNCTIONAL DESCRIPTION Current Limit Setting By placing resistance between the CS and GND pins, the current limit can be set between 100mA and 600mA within ±30% accuracy (V IN = 5 V, current limit at 600mA).
14 MB3842/MB3845 ■ TYPICAL APPLICA TION C SS R LIM R LIM C SS EN1 EN1 SS1 CS1 VIN1 VIN1 VIN2 VIN2 CS2 SS2 EN2 EN2 GND OC1 OUT1 OUT1 OUT1 OUT2 OUT2 OUT2 OC2 GND MB3842/MB3845 Top View Control signal .
15 MB3842/MB3845 ■ APPLICA TION EXAMPLE (1) Dual-P or t Self-P owered Hub Application (NON-GANG Mode Connection) 5 V USB 5 V Controller Overcurrent ON/OFF Power Supply USB Port 1 USB Port 2 MB3842/M.
16 MB3842/MB3845 (2) Dual-P or t Bus P owered Hub Application (GANG Mode Connection) USB Overcurrent ON/OFF 5 V Upstream Port MB3842/MB3845 USB Port1( × 4) USB Port2( × 4) 400 mA MAX (100 mA × 4) 4.
17 MB3842/MB3845 ■ USA GE PRECA UTION 1. Never use settings e xceeding maximum rated conditions. Exceeding maximum rated conditions may cause permanent damage to the LSI. Also, it is recommended that recommended operating conditions be observed in normal use.
18 MB3842/MB3845 ■ P A CKA GE DIMENSION C 1994 FUJITSU LIMITED F20012S-2C-4 0.50±0.20 (.020±.008) 0.10±0.10(.004±.004) (STAND OFF) 0 10° Details of "A" part 5.85(.230)REF 6.50±0.10(.256±.004) * 0.65±0.12 5.40(.213) 4.40±0.10 6.40±0.
MB3842/MB3845 FUJITSU LIMITED All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Fujitsu MB3842 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Fujitsu MB3842 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Fujitsu MB3842 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Fujitsu MB3842 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Fujitsu MB3842, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Fujitsu MB3842.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Fujitsu MB3842. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Fujitsu MB3842 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.