Foundry NetIron M2404C and M2404F Metro Access Switches Inst allation Guide ™ 4980 Great America Parkway Santa Clara, CA 95054 Tel 408.207.1700 www.foundrynetworks.
Copyright © 2007 Foundr y Net works, Inc. All rights reserved. No part of this work may be reproduced in any form or by any means – graphic, electronic or mechan ica l, including photocopyin g, recording, taping or storage in an informatio n retri eval system – without prior written permission of the copyright owner.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. ii Safety Considerations This equipment is for use in a restricted access area by qualified personnel only. To avoid electric shock, do not perform any servicing other than those contained in the u npacking instructions.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. iii WARNING GROUNDING Before connecting the product to th e power line, make sure that the protective ground terminal of the devi ce is connected to the safety ground conductor of the mains power cord.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. iv T able of Content s ABOUT THIS DOCUMENT ......................................................................................... 1 W HO S HOULD U SE T HIS G UIDE .
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. v S OFTWARE I MAGE N AMING C ONVENTIONS ................................................................. 26 D OWNLOADING A S OFTWARE I MAGE TO THE S WITC H U SING TFTP .
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 1 About This Document Who Should Use This Guide The procedures in this manual are for trained a nd qualified service personnel who are proficient with network switching and routing concepts.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 2 Conventions Used in this Document This document uses the following formatting st yles and conventions: • CLI syntax and coded examples are represente d by mono-space characters and enclosed in rectangular frames.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 3 Overview Introduction High powered networks require a combination of sp eed and robust services support to be able to provide the intensive and fluctuating demands of their end users.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 4 Hardware Description Front Panel Enhanced GigE Ports 100baseX Ports GigE Ports Switch Management Ports.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 5 3. Gently insert the SFP tranceiver into the port until the module clicks into place. The m odule is keyed to prevent incorrect insertion. See Figure 5 .
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 6 Component Description GigE Dual-Mode Ports Two dual-mode1000baseX interface (SFP) or 10/100/1000BaseT (RJ45) marked 25 and 26. Enhanced GigE Ports Two 1000baseX interface ( SFP) marked 27 and 28.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 7 Port Status LEDs A status LED is associated with each port.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 8 NetIron M2404F Dual-Mod e Port Status LEDs Figure 8: Loc ation of Net Iron M240 4F Dual-M ode Port St atus LEDs Dual-mode port status LEDs are associated with dual-mode RJ45/SFP GiGE ports 25 and 26.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 9 Rear Panel – with AC Power-Supply Units Hot-swappable PSU #2 Fan apertures Hot-swappable PSU #1 On-o.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 10 Rear Panel – with DC Power-supply Units Hot-swappable PSU #2 Fan apertures Hot-swappable PSU #1 Terminal block PWR and Invert. Con. LEDs Grounding studs Terminal block PWR and Invert.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 11 DC power-supply terminals: -48V/3A GND +BAT.RET LEDs: INVERT CON.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 12 Figure 13 Blank Filler for Empty Power-Supply Slo t.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 13 Inst allation and Setup This section provides installation and setup instru ctions. The platform can be installed in a standard 19-inch rack or as a standalone unit in a desktop configuration.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 14 WARNING Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over. Rack Mounting Specifications Width Basic body: 440 mm (17.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 15 Ethernet Cables When connecting an RJ-45/RJ-48 port to an end st ation, workstation or server, use a standard RJ-45/RJ-48 pin-out cable. Console Interface A simple menu-driven interface provides for syst em initialization and diagnostics.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 16 For each DC power block a set of a minimum 2x18AWG cables shall be used with suitable end terminal legs matching the conductor’s gauge. U se a RED lead to for the positive conductor and a BLACK lead for the negative conductor.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 17 2. Remove the bolts and spring-washers from the grounding p osts on the switch’s rear panel, and clean the metal surface underneath with a dry cloth if necessary.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 18 Initial Configuration Using the Console Initial Configuration The Configuration command-language interface (CLI) is accessed by using a VT-100 (or compatible terminal) to the console port of the sw itch.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 19 quit Disconnect and logout show Show running system information terminal Terminal configuration setup who Display who is on vty To continue initial configuration pr ocedure perform the following steps: 1.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 20 application Application downloading image java Java downloading image running-config Copy running config.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 21 Temperature Management Commands Viewing the Status: device-name # show temperature CPU Temperature = .
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 22 Monitoring the Power Supplies Status Viewing the status during system boot: BUILT-IN SELF TEST ------.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 23 Built-In Self T est (BIST) The BIST performs a set of basic hardware and configuration validity tests. Tests in the BIST are sorted into several groups – for example, the tests of the Power Suppl y units belong to a Power Supply Test group.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 24 2. Re-power the unit, if required. 3. Use the show self-test command in Privileged (Enable) mode. If you prefer to display all BIST results, use the show self-test full command instead.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 25 //////////////////////////////////////////////////////////////////// //................................................................// // FOUNDRY NETWORKS // // // // Switch model : FOUNDRY NETWORKS NETIRON M2404F 256M // // SW version : 2.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 26 Sof tware Download The executable software image contained on the platform can be upgraded via the network whenever new versions become available, reflec ting changes in the MIBs or enhancements to the software.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 27 1. Copy the device software image file to the appropriate TFTP directory on the workstation. 2. Log into the switch through the console port or through a Telnet session.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 28 6. Configure the switch to boot with the ne wly downloaded image.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 29 1. Copy the software image file to the appropriate TFTP directory on the workstation. 2. Log into the switch through the console p ort or through a Telnet session.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 30 Hot-swapping a Power Supply The switch has two redundant power supplies, a nd can be operated when only one power supply is connected and powered on, or with both po wer supplies active.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 31 S pecifications Physical Specifications Dimensions Width 440 mm (17.4”) Height 44 mm (1.73”) Depth 419 mm (16.5”) Chassis without PSU 3.7 kg (8.2 lbs) Each AC Power Supply 0.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 32 Environment: The equipment is designed for use in indoor applications only.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 33 FCC 47 CFR: 2003 part 15 subpart B, class A This equipment has been tested and found to co mply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 34 Appendix A: Cautions and W arnings Caution Statements A caution calls your attention to a possible hazard that can damage equipm ent. "Vorsicht” weist auf die Gefahr einer möglichen Beschädigung des Gerätes in.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 35 energía retirado no se reemplaza, insert e el relleno PSU en blan co provisto en el slot y asegúrelo al panel con los dos tornillos.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 36 Warning Statements A warning calls your attention to a possible hazard that can cause injury or death. The following are the warnings used in this manual.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 37 should only be performed by qualified personn el, authorized by Foundry Networks. ACHTUNG: Hochspannung Trennen Sie das Gerät vo m Netz, bevor Sie die Abdeckung abne hmen.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 38 La prise d’alimentation p ri ncipale doit être inséré e uniquement dans une prise ayant un raccordement à la terre.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 39 ADVERTENCIA: CABLEADO PARA ENCH UFE DE C O RRIENTE NACIONAL Con cada uni dad se sumi nistra un cable de alimentación principal según el Código eléctrico nacio nal (National Electri cal Code o NEC) con zócalo IEC moldeado.
Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 40 AVERTISSEMENT : Vérifiez que l e chassis ou l’armoi re incluant l’unité est bien fixé afin qu’il ne devienne pas instable ou qu’il ne risque pas de tomber.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Foundry Networks M2404C è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Foundry Networks M2404C - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Foundry Networks M2404C imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Foundry Networks M2404C ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Foundry Networks M2404C, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Foundry Networks M2404C.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Foundry Networks M2404C. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Foundry Networks M2404C insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.