233 True-rms Remote Display Digital Multimeter PN 3465366 September 2009 © 2009 Fluke Corporation. All rights rese rved. Pri nted in USA. S pecifications are subject to change without notice. All product names are trademarks of their respectiv e companies.
LIMITED WARRANTY A ND LIMITATION OF LIA BILITY This Fluke product will be free from defects in material and wo rkmanship for three years from the date of purchase. T his warranty does not cover fuses, disposable batteries, or damage from accid ent, neglect, misuse, alteration, contamination, or abnormal conditions of operation or ha nd ling.
1 Introduction The Fluke 233 (hereafter the Meter) is a co mpact and easy to operate tool for electr ical and electronic circuit measurements. XW Warning Read "Safety Information " before you use the Meter.
233 Getting Started Manual 2 Safety Information The Meter complies with: • ISA-82.02.01 • CAN/CSA C22.2 No. 61010-1-04 • ANSI/UL 61010-1:2004 • EN 61010-1:2001 • EN 61326-1:2006 • EN 61326-2-2:200 6 • ETSI EN 300 328 V1.7.1:2006 • ETSI EN 300 489 V1.
True-rms Remote Display Digital Multimeter Safety Information 3 • Remove the test leads from th e Meter before the battery door on the Meter base is opened. • Examine the test leads for damaged insulation or exposed metal. Measure th e test leads for continuity.
233 Getting Started Manual 4 • Use only specified 1.5-V AA batteries (three in the Meter base and two in the display), correctly installed, for Meter power.
True-rms Remote Display Digital Multimeter Safety Information 5 Table 1. Electrical Symbols B AC (Alternating Current) J Earth ground F DC (Direct Current) I Fuse X Hazardous voltage P Conforms to European Union directives. W Risk of Danger. Important information.
233 Getting Started Manual 6 Features See Tables 3 through 4 for a list of Meter features with a short feature descriptio n. Table 2. Display meter remote Auto RangeManual Range 1 2 3 4 5 6 8 9 11 13 12 14 10 7 gcc101.eps No. Symbol Indication 1 MIN MAX AVG mode on.
True-rms Remote Display Digital Multimeter Features 7 Table 2. Display (cont.) No. Symbol Indication 4 Radio connection indicat or. 5 ° C, ° F degr ees Celsius, degrees Fah renheit 6 A amperes (amps) V, mV volts, millivolts μ F, nF microfarad, nanofarad DC AC Direct current or alternating current.
233 Getting Started Manual 8 Table 3. Input s 1 2 3 gcc110.eps No. Terminal Description 1 A Input for 0 A to 10.00 A current measurements. 2 COM Common terminal for all measurements. 3 Input for voltage, continuity, resistance, di ode, capacitance, tem perature, and frequenc y measurements.
True-rms Remote Display Digital Multimeter Features 9 Table 4. Funct ion Switch P ositions Sw it ch Position Description Hz (button) AC voltage from 0.06 to 1000 V. Frequency from 5 Hz to 50 kHz. DC voltage from 0.001 V to 1000 V. AC voltage from 6.
233 Getting Started Manual 10 Error Messages Table 5 contains possible error messages and the steps to clear the error. Table 5. Error Messages Error Messages Display-module batteries mu st be repl aced before the Meter will operate.
True-rms Remote Display Digital Multimeter Remote Operation 11 Remote Operation 2 1 gcc114.eps Figure 1. Display Module Separation 2 1 gcc115.eps Figure 2.
233 Getting Started Manual 12 Fuse Test Good fuse: 0.0 Ω to 0.5 Ω Replace fuse: OL gcc105.eps Figure 3. Fuse Test Battery Replacement 2 3 gcc111.eps Figure 4.
True-rms Remote Display Digital Multimeter Battery Replacement 13 2 1 3 4 gcc112.eps Figure 5. Meter Base Batter y Replacement.
233 Getting Started Manual 14 General Specifications Maximum voltage betw een any terminal and earth groun d ........................................... 1000 V rms W Fuse for A inputs ..................................................... 11 A, 1000 V 17000A interrupt ra ting Fuse Altitude Operating .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Fluke 233 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Fluke 233 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Fluke 233 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Fluke 233 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Fluke 233, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Fluke 233.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Fluke 233. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Fluke 233 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.