ISS 506 Integration Seamless Switcher 68-1077-01 Rev . B 06 09.
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’ s enclosure that may present a risk of electric shock.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
.
i ISS 506 Integration Seamless Switcher • T able of Contents T able of Contents Chapter One • Introduction ...................................................................................................... 1-1 About this Manual ...............
T able of Contents, cont’d ISS 506 Integration Seamless Switcher • T able of Contents ii Output Configuration menu............................................................................................. 3-11 Resolution and refresh rate submenu .
iii ISS 506 Integration Seamless Switcher • T able of Contents T oggling background illumination on and off ................................................................... 3-37 Using front panel security lockouts (executive modes) ..............
T able of Contents, cont’d ISS 506 Integration Seamless Switcher • T able of Contents iv Using the Command/Response T ables ......................................................................... 4-11 Command/response table for SIS commands ....
v ISS 506 Integration Seamless Switcher • T able of Contents Button Label Generator ....................................................................................................... 5-27 Using the Button Label Generator software ..............
T able of Contents, cont’d ISS 506 Integration Seamless Switcher • T able of Contents vi Chapter 7 • Modifications ........................................................................................................... 7-1 Opening the Switcher .
ISS 506 Integration Seamless Switcher 1 Chapter One Intr oduction About this Manual About the Integration Seamless Switchers Features.
ISS 506 Integration Seamless Switcher • Introduction 1-2 Intr oduction About this Manual This manual contains installation, configuration, and operating information for the Extron ISS 506 family of 6-input Integration Seamless Switchers with audio.
1-3 ISS 506 Integration Seamless Switcher • Introduction 10 0-240V 50/60 H z 2A M AX R / R -Y SDI G /Y V ID S B /C B -Y H H V /V V H /H V R S23 2/422 1 L R R / R -Y 1 2 G /Y V ID B /C B -Y R / R -Y .
Intr oduction, cont’d ISS 506 Integration Seamless Switcher • Introduction 1-4 The ISS receives and outputs the ster eo audio on 5-pole captive screw connectors. The audio can be switched with cross fading (that is, the pr evious audio channel fades out and then the new audio channel fades in).
1-5 ISS 506 Integration Seamless Switcher • Introduction Audio outputs — The ISS outputs the selected unamplified, line level, balanced or unbalanced stereo or mono audio on 5-pole captive scr ew connectors.
Intr oduction, cont’d ISS 506 Integration Seamless Switcher • Introduction 1-6 T ransitions — Control the type of switch that occurs between the pr eview and program outputs. The Cut button cr eates an instant switch between the preview and pr ogram outputs.
ISS 506 Integration Seamless Switcher 2 Chapter T wo Installation Mounting the Switcher Cabling and Rear Panel Views Front Panel Configuration Port Configuration.
ISS 506 Integration Seamless Switcher • Installation 2-2 Installation Mounting the Switcher Four uninstalled rubber feet are included with the seamless switcher . If you are going to rack mount the switcher , mount it before you cable it (see “Rack mounting”, below), and do not install the rubber feet.
2-3 ISS 506 Integration Seamless Switcher • Installation Mounting instructions For optional rack mounting, do not install the rubber feet. Mount the ISS 506 in a rack as follows: 1 . Attach the included MBD 249 rack/through-desk mounting brackets to the unit, using eight machine screws supplied with the mounting kit (figur e 2-1).
Installation, cont’d ISS 506 Integration Seamless Switcher • Installation 2-4 Cabling and Rear Panel V iews All connectors are on the r ear panel (figure 2-2).
2-5 ISS 506 Integration Seamless Switcher • Installation d Input 6 video connectors — Connect either an S-video, a composite video, or an SDI/HD-SDI video source to these connectors (figur e 2-5).
Installation, cont’d ISS 506 Integration Seamless Switcher • Installation 2-6 Output connections Video output connections N The two Program V ideo outputs, consisting of one set of five BNC connectors and a 15-pin HD connector , output identical video signals at the same resolution, r efresh rate, and sync format.
2-7 ISS 506 Integration Seamless Switcher • Installation 9a DVI output connector (optional) — If the optional DVI output board (figure 2-9) is installed, connect a DVI/HDMI-compatible video display to this DVI connector . This connector outputs the program image only .
Installation, cont’d ISS 506 Integration Seamless Switcher • Installation 2-8 Audio output connections j Preview and Program audio output connectors — Connect audio devices, such as an audio amplifier or powered speakers, to these 3.5 mm, 5-pole captive screw connectors.
2-9 ISS 506 Integration Seamless Switcher • Installation Choosing a network cable Ethernet links use Category (CA T) 3, 4, 5, 5e, or 6, unshielded twisted pair (UTP) or shielded twisted pair (STP) cables, terminated with RJ-45 connectors. Ethernet cables are limited to 328' (100 m).
Installation, cont’d ISS 506 Integration Seamless Switcher • Installation 2-10 Serial port connection l RS-232/422 port — Connect a host device, such as a computer or touch panel control, to the ISS 506 Integration Seamless Switcher via this 9-pin D connector for serial RS-232 or RS-422 control (figur e 2-14).
2-11 ISS 506 Integration Seamless Switcher • Installation Fr ont Panel Configuration Port TRANSITION PICTURE ADJUSTMENTS CONFIG ZOOM T AKE PIP TITLE SIZE DET AIL POSITION BRIGHT/ CONT COLOR/ TINT I.
Installation, cont’d ISS 506 Integration Seamless Switcher • Installation 2-12 Configuration The ISS can be configured using either the fr ont panel controls, the SIS, the HTML pages, or the W indows-based Control program.
ISS 506 Integration Seamless Switcher 3 Chapter Thr ee Operation Front Panel Controls and Indicators Front Panel Operations Rear Panel Reset Button Optimizing the Video Optimizing the Audio T roublesh.
ISS 506 Integration Seamless Switcher • Operation 3-2 Operation Fr ont Panel Controls and Indicators All of the switcher ’s contr ols and indicators, with the exception of the Reset button, are on the fr ont panel (figure 3-1).
3-3 ISS 506 Integration Seamless Switcher • Operation e T ake button — Pressing the T ake button causes the ISS to switch the input that was selected as the preview output with the pr ogram output, using the effect that was selected by the lit Ef fect button ( f ).
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-4 h Status display — The 16-column by 2-line LCD window displays configuration menus and status information. See “Menu system overview”, below , and “Front Panel Operations”, later in this chapter , for details.
3-5 ISS 506 Integration Seamless Switcher • Operation Default Cycle Menu 2 sec. Po wer on Men u Next Men u Men u Men u * This me nu is av ailable only if the optional scan con ve r ter board is installed.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-6 Auto Image menu Figure 3-3 shows an overview of the Auto Image menu, the Select output submenu, and the available settings. • Program • Previe w • Both Default Cycle Menu Menu 30 sec.
3-7 ISS 506 Integration Seamless Switcher • Operation Default Cycle Menu Menu Men u Menu Next Menu Menu Menu Menu Menu Menu Menu Input Configuratio n Au to Image Output Configuratio n Effect s Configuratio n Logo Capture User Preset s Ad va nced Configuratio n View Comm Setting s Scan Con verter Configuratio n Exit Menu Press Next * 30 sec.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-8 Audio Level submenu Rotate the Adjust [ knob while the Input format submenu is active to select an input to configure. Rotate the Adjust { knob to select the audio gain or attenuation value, from -18 dB to +24 dB.
3-9 ISS 506 Integration Seamless Switcher • Operation This early scaling results in a blank border on the left side and cr opping on the right side, and looks as if the image is shifted to the right.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-10 These lines appear as fuzzy vertical bars when an alternating pixels pattern is applied. When the total pixels setting is improperly adjusted, the entir e image can have a noisy or darkened appearance.
3-11 ISS 506 Integration Seamless Switcher • Operation Adjust the Active Pixels variable to increase and decr ease the number of active pixels, shifting the starting period horizontally on the screen. Adjust the Active Lines variable to increase and decr ease the number of lines.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-12 Resolution and refr esh rate submenu Rotate the Adjust [ knob while this submenu is active to select one of the available output resolutions.
3-13 ISS 506 Integration Seamless Switcher • Operation Output T ype submenu Rotate either Adjust knob while this submenu is active to select the output video type (RGBHV , RGsB, component [YUV] with tri-level sync, or component [YUV] with bi-level sync).
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-14 Dissolve Conguration submenu The Dissolve Duration submenu displays and allows you to set the duration of the dissolve effect that is applied when you ar e switching the preview output to the program output or switching among pictur e-in-picture window inputs.
3-15 ISS 506 Integration Seamless Switcher • Operation WIPE RIGHT SOFT WIPE LEFT SOFT WIPE UP SOFT WIPE DOWN SOFT WIPE CENTER IN SOFT WIPE CENTER OUT SOFT WIPE CURT AIN IN SOFT WIPE CURT AIN OUT SOF.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-16 Logo Capture menu Figure 3-1 1 is a flowchart that shows an overview of the Logo Capture menu, the submenus, and the available settings. See “Capturing a logo” on page 3-30 for more details on using this menu.
3-17 ISS 506 Integration Seamless Switcher • Operation Capture Start submenu The Capture Start submenu displays and allows you to set the starting point of the logo to be captured. Use this submenu, along with the Captur e Size submenu to define the area to be saved as a logo.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-18 User Presets menu Figure 3-12 is a flowchart that shows an overview of the User Pr esets menu, the Save User Preset and Erase User Pr eset submenus, and the available settings.
3-19 ISS 506 Integration Seamless Switcher • Operation N The User Preset is tailor ed for the selected output rate. If you change the output rate and then recall a pr eset for the earlier rate, the adjustments recalled in the preset have no effect on the video output.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-20 Auto Image submenu The Auto Image submenu provides a means to turn the auto imaging on or of f for individual input selections. If auto imaging is set to on, the ISS always sizes and centers the selected input to fill the screen when a new fr equency is input.
3-21 ISS 506 Integration Seamless Switcher • Operation Split Color Bars (8) Crosshatch Crosshatch 4x4 Split Grayscale Ramp Alt Pixels Crop 1.78 Aspect Ratio 1.33 Aspect Ratio 1.85 Aspect Ratio 2.35 Aspect Ratio Figure 3-14 — T est patterns Blue Mode submenu The Blue Mode submenu lets you turn the blue-only mode feature on and of f.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-22 Preview Switch Mode submenu The Preview Switch Mode submenu lets you set the way the pr eview output responds to the cut or take operation.
3-23 ISS 506 Integration Seamless Switcher • Operation View and Edit Communications Settings menu Figure 3-16 is a flowchart that shows an overview of both the V iew User Communications Settings and the Edit User Communications Settings menus, the submenus, and the available settings.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-24 MAC Address display The read-only MAC Address display shows the hardcoded, factory assigned hardwar e address. DHCP Mode submenu The DHCP Mode submenu displays the on or of f status of the Dynamic Host Configuration Protocol (DHCP) method of IP addressing.
3-25 ISS 506 Integration Seamless Switcher • Operation Scan Converter Configuration menu Figure 3-17 is a flowchart that shows an overview of the Scan Converter Configuration menu, the submenus, and the available settings. The Scan Converter Configuration menu is displayed only if an optional scan converter output board is installed.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-26 Output Format submenu The Output Format submenu displays and allows you to change the format of the scan converted output. When this submenu is active, rotate either Adjust knob to select among RGsB, low resolution component video (YUV), or composite video and S-video.
3-27 ISS 506 Integration Seamless Switcher • Operation Exit menu From the Exit menu (figur e 3-18), press the Next button to r eturn to the default display cycle, or press the Menu button to r eturn to the Auto Image menu.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-28 The selected preview and pr ogram inputs, the picture adjustments, and other current settings ar e saved in nonvolatile memory . When power is applied, the latest configuration is retrieved.
3-29 ISS 506 Integration Seamless Switcher • Operation Selecting an input to be the preview output and switching it to the program output N In this example, the switcher is set to Swap mode. See “Preview Switch Mode submenu”, earlier in this chapter .
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-30 T ake button — The ISS switches the input selected as the preview output to the program output using the ef fect selected by one of the Effect buttons (figure 3-22).
3-31 ISS 506 Integration Seamless Switcher • Operation Capturing a logo The ISS can capture an on-scr een image to use as a logo. N A logo is a bitmap image that can be superimposed on top of the preview and/or program output. Capture a displayed image as a logo as follows: 1 .
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-32 6 . Press the Next button (figur e 3-25). The Capture Size submenu appears. Default Cycle Press NEXT Step 6 Press NEXT Step 8 Press NEXT Step 10 Step 11 Rotate the knobs to mo ve the lo wer-r ight corner of the image area to be captured.
3-33 ISS 506 Integration Seamless Switcher • Operation Configuring a logo Once a bitmap is captured or uploaded via the LAN port, you can assign it to one of the two logo locations. After it is assigned, you can position it and remove (key out) unwanted portions of the image (such as backgrounds).
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-34 6 . Rotate the Adjust { knob to select (< >) how you will remove (key out) unwanted portions of the bitmap. Level — The ISS keys out all material whose luminance level is below a variable threshold.
3-35 ISS 506 Integration Seamless Switcher • Operation Configuring a title The ISS can display the input that is selected to be the preview output as a title. N A title is preview output superimposed over the pr ogram output. Remove (key out) unwanted portions of the title (such as backgrounds) as follows: 1 .
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-36 Adjusting the picture The picture adjustments allow you to fine tune the image quality of the selected input.
3-37 ISS 506 Integration Seamless Switcher • Operation Adjust an image as follows (figure 3-29). 1. Press the desir ed input button to select the input to adjust. N The adjustments are made to the input signal that is switched to the output (preview or pr ogram) shown in the LCD window .
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-38 Using front panel security lockouts (executive modes) There ar e four levels of front panel security lockout that limit the various aspects of the operation of the ISS 506 Integration Seamless Switcher from the fr ont panel.
3-39 ISS 506 Integration Seamless Switcher • Operation Rear Panel Reset Button The switcher ’s Reset button is on the r ear panel (figure 3-32). RS232/422 RESET B/ B-Y PREVIEW RGB/R- Y, Y, B-Y RG.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-40 Perform a soft reset of the switcher as follows: 1 . Use an Extron tweeker or other small scr ewdriver to press and hold the Reset button until the Reset LED blinks once (for events reset), twice (for IP settings), or three times (for absolute r eset) (figure 3-33).
3-41 ISS 506 Integration Seamless Switcher • Operation Performing a hard r eset The hard r eset function restor es the switcher to the base firmware that it was shipped with. After a hard reset, events do not automatically start, but user settings and files are r estored.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-42 3 . Select an input. Use the ISS’s size and center functions to adust the crop or aspect ratio output to fill the screen.
3-43 ISS 506 Integration Seamless Switcher • Operation T roubleshooting The following tips may help you in troubleshooting. • Somesymptomsmayresembleothers,soyoumaywanttolookthr oughall of the examples before attempting to solve the pr oblem.
Operation, cont’d ISS 506 Integration Seamless Switcher • Operation 3-44 Specific problems The table below shows some common operating problems and their solutions. Problem Cause Solution No image appears. The input signal is Connect an input device that is incompatible.
ISS 506 Integration Seamless Switcher 4 Chapter Four SIS Pr ogramming and Control Serial Links Ethernet Link Symbols Switcher-Initiated Messages Host-to-Switcher Instructions Switcher Error Responses .
ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-2 SIS Pr ogramming and Contr ol Serial Links The switcher has two serial ports that can be connected to a host device such as a computer running the HyperT erminal utility , an RS-232 capable PDA, or a control system.
4-3 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Front panel Configuration port N This port is hardwired for RS-232 only . N This port is independent of the rear panel RS-232/RS-422 port. A front panel Configuration port connection and a rear panel RS-232/RS-422 port connection can both be active at the same time.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-4 Ether net Link The rear panel Ethernet connector on the switcher (figur e 4-3) can be connected to an Ethernet LAN or W AN. This connection makes SIS control of the switcher possible using a computer connected to the same LAN or W AN.
4-5 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Symbols Symbols ( X / values), defined below , are used throughout the discussions of the switcher-initiated messages that begin on the next page and the command/ response table that begins on page 4-12.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-6 X4$ = Frequency: nnn . nn (kHz [horizontal] or Hz [vertical]) X4% = Lockout mode: 0 = .
4-7 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Title Eff3* X^ * nnn * 1 * X& ] The operator has pressed the Ef fect T itle button on the front panel. Eff3 indicates “title”. X^ is the key threshold. “ nnn ” has no meaning in this r esponse.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-8 Cutting or dissolving in swap mode The switcher issues the following reports when you swap the pr eview and program outputs in stay mode: Tke1* X* ] The switcher has received the fr ont panel T ake command.
4-9 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Picture adjustments X@ Col X2& ] A front panel color adjustment has occurred. X@ is the output (pr ogram or preview) switched to the adjusted input and X2& is the color variable.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-10 RGB delay Dly X# ] A front panel RGB delay adjustment has occurred. RGB delay affects input selections for the preview output only . X# is the delay value, in 0.
4-11 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Host-to-Switcher Instructions The switcher accepts SIS commands through its serial ports and/or its LAN port. SIS commands consist of one or more characters per command field.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-12 Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Respo.
4-13 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command/response table for SIS commands (continued) Command/response table for SIS commands (continued) Command ASCII (T eln.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-14 Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to .
4-15 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to sw.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-16 Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to .
4-17 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Additional description Video mute V ideo mute on X@ *1B X@ *1B X@ Vmt1 ] Set the X@ video output to black.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-18 Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to .
4-19 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to sw.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-20 Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to .
4-21 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to sw.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-22 Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to .
4-23 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Additional description Blue screen T urn blue screen mode on 8*1# 8*1# Blu1 ] Output sync and blue video only on both outputs.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-24 Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to .
4-25 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to sw.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-26 Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to .
4-27 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Additional descr.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-28 Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Respo.
4-29 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Additional description PIP image horizontal size Set a specific horizontal size 4* X1^ : 4* X1^ : 4Hsz X1^] Set the PIP image’s horizontal size to X1^ .
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-30 Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Respo.
4-31 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Additional descr.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-32 Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Additional description Scan converter flicker filter N The command (d) is case sensitive .
4-33 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command/response table for SIS commands (continued) N X! = Input number 1 – 6 X@ = Output 1 = Pr ogram 2 = Preview 3 = PIP window 4 = PIP image X1) = V ideo type (see page 4-5).
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-34 Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Additional description Information requests (continued) Query part number N N 60-742- xx ] See appendix B for part numbers.
4-35 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command/Response T able for IP SIS Commands Symbol definitions X7) = Switcher name (Up to 240 alphanumeric characters) N The following characters are invalid in the name: {space} ~ , _ @ = ` [ ] { } < > ‘ “ ; : | and ?.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-36 Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Respo.
4-37 ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to sw.
SIS Pr ogramming and Control, cont’d ISS 506 Integration Seamless Switcher • SIS Programming and Contr ol 4-38 Special Characters The HTML language reserves certain characters for specific functions. The switcher does not accept these characters as part of preset names, the switcher ’s name, passwords, or locally cr eated file names.
ISS 506 Integration Seamless Switcher 5 Chapter Five Switcher Softwar e ISS 506 Control Program Button Label Generator Special Characters.
ISS 506 Integration Seamless Switcher • Switcher Software 5-2 Switcher Softwar e ISS 506 Contr ol Program The W indows-based Extron ISS 506 Control Pr ogram, which communicates with the switcher via.
5-3 ISS 506 Integration Seamless Switcher • Switcher Software 4 . Follow the on-screen instructions. By default, the W indows installation of the Matrix Switchers Control Pr ogram creates a C:Pr ogram Files Extron ISS506, and it places four icons into a gr oup folder named “Extron ElectronicsMatrix Switchers.
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-4 Using the software Many items found in the ISS 506 Control Pr ogram are also accessible via fr ont panel controls (see chapter 3, “Operation”) and under SIS contr ol (see chapter 4, “SIS Programming and Contr ol”).
5-5 ISS 506 Integration Seamless Switcher • Switcher Software When the program starts satisfactorily , the Extron ISS 506 Contr ol Program Contr ol window (figure 5-4) appears.
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-6 • TheProgramandPr eviewFreeze,inputselection,andLogo/Black buttons work exactly as similar buttons on the front panel.
5-7 ISS 506 Integration Seamless Switcher • Switcher Software • ThePictureradiobuttonselectspictur econtroladjustmentsthatpr ovide thesamefunctionsasthePicture Adjustmentbuttonsonthefrontpanel (gure5-6).
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-8 I/O Configuration window The I/O Configuration window (figure 5-7) pr ovides a location for viewing and changing input and output configuration settings.
5-9 ISS 506 Integration Seamless Switcher • Switcher Software Logo Setup/Capture window The Logo Setup/Capture window (figur e 5-8) consists of two areas: the logo capture ar ea (on the right) and the logo setup area (on the left). See chapter 3, “Operation”.
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-10 4 . Click in the Enter logo name field, type in a name for you logo, and click the Start Capture button. The pr ogram displays a window that shows the progr ess of the capture (figur e 5-9).
5-11 ISS 506 Integration Seamless Switcher • Switcher Software N As a simpler alternative, if you selected the Key T ype Color radio button, you can click the Pick Color button. The program pops up a window containing the logo and a color picker cursor (figure 5-1 1).
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-12 Advanced Setup window The Advanced Setup window (figure 5-12) pr ovides a location for viewing and changing most advanced configuration settings.
5-13 ISS 506 Integration Seamless Switcher • Switcher Software Scan Converter Setup window N The Scan Converter Setup tab and window are available only if your ISS has the optional scan converter output board installed (either included as delivered [ISS 506 SC or ISS 506 DI/SC] or installed after purchase [part # 70-486-01 ].
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-14 System Settings IP settings window The IP settings window (figur e 5-15) provides a location for viewing .
5-15 ISS 506 Integration Seamless Switcher • Switcher Software Gateway eld The Gateway field identifies the address of the gateway to the mail server to be used if the switcher and the mail server are not on the same subnet. V alid IP addresses consist of four 1-, 2-, or 3-digit octets separated by dots (periods).
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-16 System Settings RS-232 window Figure 5-16 — System Settings RS-232 window Only the baud rate can be chan.
5-17 ISS 506 Integration Seamless Switcher • Switcher Software System Settings Date/Time window Figure 5-17 — System Settings Date/Time window Sync Date & Time to PC button Click in the Sync D.
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-18 Time (local) eld The T ime (local) field displays the current time in the local time zone.
5-19 ISS 506 Integration Seamless Switcher • Switcher Software N Editing the Administrator Password field while connected via the LAN port does not affect your current login.
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-20 6 . Start the ISS 506 Contr ol Program. See “Using the softwar e”, steps 1 through 4 , starting on page 5-4. 7 . Click Tools > Update firmware . The Extr on Firmware Loader port configuration window appears (figure 5-21).
5-21 ISS 506 Integration Seamless Switcher • Switcher Software 10 . Click the OK button. The Extron Firmwar e Loader appears (figure 5-22). Figure 5-22 — Firmwar e loading 11 . Click Browse . The open file window appears. 12 . Navigate to the folder where you saved the firmwar e upgrade file.
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-22 Uploading images N The IP Link File Manager must be installed on your computer to perform this operation. Extron r ecommends that you install this program when you install the ISS 506 Control Pr ogram.
5-23 ISS 506 Integration Seamless Switcher • Switcher Software Figure 5-24 — IP Link File Manager pr ogram window 5 . Check to see that the ISS contents include the directory “nortxe-graphics“. If the “nortxe-graphics“ directory is present in the ISS, proceed to step 6 .
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-24 7 . Delete images from the ISS by clicking on them, pr essing the PC’s Delete key , and clicking Yes in the advisory box that appears. Windows menus File menu Reselect Connection .
5-25 ISS 506 Integration Seamless Switcher • Switcher Software T ools menu Unit Info ... — Opens a window (figure 5-26) that provides basic information about the status of the ISS, including the model name and number , the installed daughterboards, the firmware version and build, and the internal temperature.
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-26 Data View/Trace Window ... — Calls the trace log window (figure 5-26), which shows the serial communications, in ASCII and Hex, between the controller and the ISS.
5-27 ISS 506 Integration Seamless Switcher • Switcher Software Using the help system For information about program featur es, you can access the help program in any of the following ways: • FromtheExtr onElectronicspr ogramfolderorgroup, double-click on the ISS 506 Help icon (shown at right).
Switcher Softwar e, cont’d ISS 506 Integration Seamless Switcher • Switcher Software 5-28 Figure 5-29 — Extr on’ s Button Label Generator window 2 . Under System selection, choose SGS 408 (this selection matches the button size of the ISS 506).
ISS 506 Integration Seamless Switcher 6 Chapter 6 HTML Operation Downloading the Startup Page System Status T ab Configuration T ab File Management T ab Control T ab Special Characters.
ISS 506 Integration Seamless Switcher • HTML Operation 6-2 HTML Operation The switcher can be controlled and operated thr ough its LAN port, connected via a LAN or W AN, using a web browser such as Microsoft’s Internet Explor er . The browser ’s display of the switcher ’s status or operation has the appearance of web pages.
6-3 ISS 506 Integration Seamless Switcher • HTML Operation 7 . The switcher checks several possibilities, in the following order , and then responds accor dingly: • Does the address include a specific file name, such as 10.13.156.10/ file_name.
HTML Operation, cont’d ISS 506 Integration Seamless Switcher • HTML Operation 6-4 Configuration T ab System Configuration page The ISS 506 switcher downloads the System Configuration page (figure 6-3) when you click the Configuration tab . The screen consists of fields in which you can view and edit IP administration and system settings.
6-5 ISS 506 Integration Seamless Switcher • HTML Operation IP Address eld The IP Address field contains the IP addr ess of the connected switcher . This value is encoded in the switcher ’s flash memory . V alid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields, pr operly called octets, separated by dots (periods).
HTML Operation, cont’d ISS 506 Integration Seamless Switcher • HTML Operation 6-6 3 . Repeat steps 1 and 2 for other variables that need to be changed. 4 . If appropriate, select the Daylight Saving radio button to turn on the daylight savings time feature.
6-7 ISS 506 Integration Seamless Switcher • HTML Operation T o select and output a test pattern, use the T est Pattern dropbox in the Advanced Configuration area to select the desir ed pattern (Color Bars; crosshatch; 4 x 4 crosshatch; split grayscale; ramp; alternating pixels; cr op; or film aspect ratios of 1.
HTML Operation, cont’d ISS 506 Integration Seamless Switcher • HTML Operation 6-8 Use the and buttons to increment and decrement the horizontal and vertical shift; horizontal and vertical size; and the flicker , horizontal, and encoder filters (or use the dropboxes for the filters).
6-9 ISS 506 Integration Seamless Switcher • HTML Operation Email Alerts page Reach the Email Alerts page (figure 6-8) by clicking the Email Alerts link on the System Configuration page. The Email Alerts screen enables you to set up the ISS 506 to automatically send e-mail alert messages when settings are changed on the ISS 506.
HTML Operation, cont’d ISS 506 Integration Seamless Switcher • HTML Operation 6-10 T o set up e-mail addresses for notification, do the following for each recipient of e-mail alerts: 1 . Click the Edit button at the end of the address r ow . The Edit button changes to Save .
6-11 ISS 506 Integration Seamless Switcher • HTML Operation Update the switcher firmware as follows: N The Firmware Upgrade page is only for r eplacing the firmware that contr ols all switcher operation. T o insert your own HTML pages, see “File Management Page”, on page 6-12.
HTML Operation, cont’d ISS 506 Integration Seamless Switcher • HTML Operation 6-12 File Management T ab File Management page T o delete files such as logo bitmaps from the switcher or to upload your own HTML files to the switcher , click the File Management tab.
6-13 ISS 506 Integration Seamless Switcher • HTML Operation Contr ol T ab User Control page Y ou can perform most of the front panel operations on the User Control page (figure 6-12).
HTML Operation, cont’d ISS 506 Integration Seamless Switcher • HTML Operation 6-14 Preset page Y ou can save and recall user presets and input pr esets from the Presets page (figure 6-13). Access the Presets page by clicking the Presets link on the User Control page.
6-15 ISS 506 Integration Seamless Switcher • HTML Operation Input presets N User presets consist of: • Filmmode • T otalpixels • Programphase • Previewphas.
HTML Operation, cont’d ISS 506 Integration Seamless Switcher • HTML Operation 6-16 Logos page Y ou can assign images to either logo and set the variables associated with the logo function from the Logos page (figur e 6-15). Y ou can also upload your own images to serve as logos and delete unwanted images.
6-17 ISS 506 Integration Seamless Switcher • HTML Operation Figure 6-16 — Add Image field Deleting an image Delete an unwanted image as follows: 1 . In the Image Index Field, click the unwanted image. 2. Click the Delete button. The computer deletes the selected image from the ISS.
HTML Operation, cont’d ISS 506 Integration Seamless Switcher • HTML Operation 6-18 4 . W atch the logo on the connected output device while you slowly drag the slider up and down (figure 6-17) to key out unwanted material, such as the background, fr om the logo.
ISS 506 Integration Seamless Switcher 7 Chapter 7 Modifications Opening the Switcher Installing an Optional SDI/HD-SDI Input Board Installing an Optional Output Board Closing the Switcher Button Labe.
ISS 506 Integration Seamless Switcher • Modications 7-2 Modifications The ISS 506 can be modified to install or remove optional boar ds that change the input and/or output formats that the switcher can process.
7-3 ISS 506 Integration Seamless Switcher • Modications 4 . Lift the top cover straight up approximately 5 inches until you can access the fan power cord. C Do not touch any electronic components inside the ISS. Doing so could damage the switcher .
Modifications, cont’d ISS 506 Integration Seamless Switcher • Modications 7-4 3 . From the inside of the switcher , pop the cover out of the rear panel connector port ( c ). 4 . See figure 7-3. T ip the input board up and guide its output connector thr ough the rear panel connector port ( d ).
7-5 ISS 506 Integration Seamless Switcher • Modications 7 . Secure the input boar d to the back panel with the included hex nut (figure 7-5). SDI S H RS232/422 VID /Y R-Y VID B-Y /C V G /Y R R-Y.
Modifications, cont’d ISS 506 Integration Seamless Switcher • Modications 7-6 Installing an Optional Output Boar d Y ou can install one of three optional output boards in the ISS.
7-7 ISS 506 Integration Seamless Switcher • Modications 3 . On the main board (figur e 7-7), locate connectors J1, J2A, and J2B ( b ); the standoff ( c ); and the r ear panel connector port ( d ).
Modifications, cont’d ISS 506 Integration Seamless Switcher • Modications 7-8 5 . See figure 7-9. Align the connector(s) on the output board with those on the extension(s) ( f ). Gently apply pressur e to carefully mate the output boar d with the extension(s).
7-9 ISS 506 Integration Seamless Switcher • Modications 6 . See figure 7-10. Secur e the output board to the standof f on the main board with the included screw ( h ). 8 Figure 7-10 — Secur e the output board to the standof f 7 . Secure the output boar d to the back panel with the two screws ( i ) r emoved in step 2 (figure 7-1 1).
Modifications, cont’d ISS 506 Integration Seamless Switcher • Modications 7-10 Closing the Switcher 1 . Reconnect the fan power cord to connector J46 on the main boar d. 2 . Replace the top cover on the ISS. 3 . Fasten it with the screws that wer e removed in “Opening the Switcher“, step 3 .
7-11 ISS 506 Integration Seamless Switcher • Modications Button label blanks.
Modifications, cont’d ISS 506 Integration Seamless Switcher • Modications 7-12.
ISS 506 Integration Seamless Switcher A Appendix A Ether net Connection Ethernet Link Subnetting — A Primer.
ISS 506 Integration Seamless Switcher • Ethernet Connection A-2 Ether net Connection Ether net Link The rear panel Ethernet connector on the ISS 506 can be connected to an Ethernet LAN or W AN. This connection makes SIS control of the switcher possible using a computer connected to the same LAN.
A-3 ISS 506 Integration Seamless Switcher • Ethernet Connection Ping the switcher as follows: 1 . On the W indows task bar , click Start > Run. 2 . At the Open prompt, type command. 3 . Click the OK button. 4 . At the DOS prompt, type ping {IP addr ess} and then press Enter .
Ether net Connection, cont’d ISS 506 Integration Seamless Switcher • Ethernet Connection A-4 Microsoft (R) windows 2000 (TM) Version 5.0 (Build 2195) Welcome to Microsoft Telnet Client Telnet Client Build 5.
A-5 ISS 506 Integration Seamless Switcher • Ethernet Connection Local echo Once connected to the ISS 506, by default, T elnet does not display your keystrokes on the screen. SIS commands ar e typed in blindly and only the SIS responses ar e displayed on the screen.
Ether net Connection, cont’d ISS 506 Integration Seamless Switcher • Ethernet Connection A-6 Subnetting — A Primer It is not the purpose of this manual to describe TCP/IP protocol in detail.
A-7 ISS 506 Integration Seamless Switcher • Ethernet Connection Determining whether devices are on the same subnet T o determine the subnet, the local device’s IP address is compared to the r emote device’s IP addr ess (figure A-6).
Ether net Connection, cont’d ISS 506 Integration Seamless Switcher • Ethernet Connection A-8.
ISS 506 Integration Seamless Switcher B Appendix B Refer ence Information Specifications Part Numbers and Accessories.
ISS 506 Integration Seamless Switcher • Reference Information Refer ence Information B-2 Specifications Video input Number/signal type .............
ISS 506 Integration Seamless Switcher • Reference Information B-3 Scaled resolution ........................... 640x480 1,2,3,4,5,6 , 800x600 1,2,3,4,5,6 , 852x480 1,2,3,4,5 , 1024x768 1,2,3,4 , 102.
Refer ence Information, cont’d ISS 506 Integration Seamless Switcher • Reference Information B-4 Audio output Number/signal type ..................... 3 stereo, balanced/unbalanced (2 pr ogram, 1 preview) Connectors ...............................
B-5 ISS 506 Integration Seamless Switcher • Reference Information Part Numbers and Accessories ISS 506 part numbers The following ISS 506 models are available: Switcher model Part number ISS 506 60-.
Refer ence Information, cont’d ISS 506 Integration Seamless Switcher • Reference Information B-6.
Extr on W arranty Extron Electr onics warrants this product against defects in materials and workmanship for a period of three years fr om the date of purchase.
© 2009 Extron Electr onics. All rights r eserved. Ex tron US A - We st Headquar te rs +8 00 .6 33 .9 87 6 Insid e U S A / C anad a O nl y +1 .7 14 .4 91 .1 50 0 +1 .7 14 .4 91 .1 51 7 FA X Ex tron US A - East +8 00 .6 33 .9 87 6 Insid e U S A / C anad a O nl y +1 .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Extron electronic ISS 506 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Extron electronic ISS 506 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Extron electronic ISS 506 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Extron electronic ISS 506 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Extron electronic ISS 506, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Extron electronic ISS 506.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Extron electronic ISS 506. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Extron electronic ISS 506 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.