Manuale d’uso / di manutenzione del prodotto DMS 3600 del fabbricante Extron electronic
Vai alla pagina of 25
Setup Guide 68-1829-50 Rev . C 09 13 DMS 1600, DMS 2000, DMS 3200, DMS 3600 Configurable Digital Video Matrix Switchers Matrix Switchers.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the FCC rules. The ClassA limits provide r easonable protection against harmful interference when the equipment is operated in a commercial envir onment.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Contents v Software Commands Commands are written in the fonts shown her e: ^A R Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C [01] R 0004 00300 00400 00800 00600 [0.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction 1 vi DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Contents Intr oduction WARNING : Risk of serious physical injury — The DMS ber optic I/O boards output continuous invisible light, which may be harmful to the eyes; use with caution.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction 2 3 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction About the DMS Matrix Switchers The DMS 1600, DMS 2000, DMS 3200, and DMS 3600 (see gure 1) are congurable matrix switchers that distribute DVI signals and DFX transmitter and receiver outputs and inputs.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 5 4 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction Installation This section describes installation of the DMS matrix switchers, including connections and features.
6 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 7 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation ANAHEIM, CA RESET RS232/RS422 REMOTE LAN ACT LINK REDUNDANT PRIMARY PRIMARY POWER SUPPL Y REDUNDANT POWER SUPPL Y FAN ASSIMB LY FAN ASSIMB LY 100-240V 50-60Hz 2.
8 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 9 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation e Remote port — If desired, connect a contr ol system or computer to the rear panel Remote RS-232/RS-422 port.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations 11 10 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation Fr ont Panel Operations This section describes simple DMS matrix switcher operation from the front panel.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 13 12 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations Remote Contr ol This section describes using the remote contr ol features of the DMS matrix switchers to control the devices.
14 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 15 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Number of connections A switcher can have up to 200 simultaneous TCP connections, including all HTTP sockets and T elnet connections.
15 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Command and Response T able for SIS Commands Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description NOTES : • Commands can be entered back-to-back in a string, with no spaces.
16 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 17 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description EDID NOTE: In the commands below , the EDID data can come from either an active output or be set to a specied value.
18 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 19 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description Channel mute commands Channel mute X@ *1B Vmt X@ *1 ] Mute output X@ (no signal is output).
20 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control NOTE: X1! = Address nnn . nnn . nnn . nnn X1@ = DHCP 0 = off, 1 = on Command ASCII Command (host to unit) Response (unit to host) Additional Description IP and serial port setup Set IP address EX1! CI } Ipi X1!] Default: 192 .
21 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Installing and Starting the Control Pr ogram Another way to operate the switcher is via the Windows ® -based Matrix Switchers Control Pr ogram. This program is contained on the Extr on Software Pr oducts DVD (included with the switcher) or on the website.
22 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 23 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 4. Follow the on-screen instructions. The installation program cr eates a C:Program FilesExtr onMatrix_Switchers directory and an “Extr on ElectronicsMatrix Switchers” gr oup folder .
24 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 25 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 4. If you selected IP [LAN] in step 2, the IP Connection window appears. Figure 12. IP Connection Window a. Examine the Matrix IP Address eld, which displays the last Matrix IP address enter ed.
26 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 27 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 5. Execute a ping command by entering ping followed by a space and the new IP address at the command pr ompt. For example: ping 10 .
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 29 28 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Maintenance and Modifications This section describes repairing and r econguring the DMS matrix switchers by replacing components.
30 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 31 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications ANAHEIM, CA RESET REMOTE RS-232/RS-422 LAN BI-LEVEL TRI-LEVEL ACT LINK 100-240V 50/60Hz 1.2A MAX.
32 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 33 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 3. Slide the power supply out of the chassis. 4. Orient the power supply module to be installed with the LED to the right.
34 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications.
Extron W arranty Extron Electr onics warrants this product against defects in materials and workmanship for a period of three years fr om the date of purchase.
Extron USA Headquarters +800.633.9876 (Inside USA/Canada Only) Extron USA - W est Extr on USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 F AX +1.919.850.1001 F AX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Extron electronic DMS 3600 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Extron electronic DMS 3600 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Extron electronic DMS 3600 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Extron electronic DMS 3600 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Extron electronic DMS 3600, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Extron electronic DMS 3600.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Extron electronic DMS 3600. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Extron electronic DMS 3600 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.