Cabinet Hardmount Refer to Page 5 for Model Identification
Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.)
Part No. F232135R6
June 2005




© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 2 F232135

Important Safety Instructions
Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.
To reduce the risk of fire, electric shock, serious injury or death to persons when using your washer, follow these basic precautions:
5. Under certain conditions, hydrogen gas may be produced in a hot water system that has not been used for two weeks or more. HYDROGEN GAS IS EXPLOSIVE. If the hot water system has not been used for such a period, before using a washing machine or combination washer-dryer, turn on all hot water faucets and let the water flow from each for several minutes. This will release any accumulated hydrogen gas. The gas is flammable, do not smoke or use an open flame during this time.
Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions.
3 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Any problems or conditions not understood should be reported to the dealer, distributor, service agent or the manufacturer.
F232135 4 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Information in this manual is applicable to these models:
5 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

This manual is designed as a guide to the installation of the Cabinet Hardmount Washer-Extractor.
The nameplate is located at the rear of the machine and inside door. Always provide the machine’s serial number and model number when ordering parts or when seeking technical assistance. Refer to Figure 1.
Upon delivery, visually inspect crate, protective cover, and unit for any visible shipping damage. If the crate, protective cover, or unit is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered.
Remove the crate and protective cover as soon after delivery as possible. If any damage is discovered upon removal of the crate and/or protective cover, advise the carrier and file a written claim immediately.
F232135 6 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
CHM167R 1 Nameplate

7 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
* Denotes Brand

Replacement Parts
Remove After Shipment (OPL Models Only)
If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950 for the name and address of the nearest authorized parts distributor.
A yellow retainer has been inserted in the door locks of all cabinet hardmount on-premise laundry washer- extractors to prevent the door from locking during shipment. Remove the yellow retainer during installation by pulling it off.
For technical assistance, call (920) 748-3121, Ripon, Wisconsin U.S.A.
A tag has been attached to the washer-extractor’s door handle as a reminder that the retainer must be removed before operation. Refer to Figure 3.
Remove Yellow Retainer Before Starting Machine.
F232135 8 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232135 10 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

2 Speed Models (Continued)
Specification 18/20 25 27, 30 35 40 50 60
Balance Detection
Vibration switch installed N/A
Steam inlet connection size, in. (mm)
Number of steam inlets 1
Steam required to raise bath water temperature 10°F (6°C)
LOW 1.05 (0.75) 1.4 (1.01) 1.44 (1.03) 2.06 (1.48) 2.09 (1.51) 2.76 (1.99) 2.76 (1.99)
HIGH 1.4 (1.01) 1.59 (1.15) 1.91 (1.37) 2.69 (1.94) 2.84 (2.04) 3.59 (2.59) 3.59 (2.59)
Average steam use per cycle, bhp (kg)
0.71 (11.1)
0.87 (13.6)
0.97 (15.2)
1.4 (21.6)
1.43 (22.4)
1.84 (28.9)
1.84 (28.9)
Total electrical heating capacity, kW
7.8 7.8 7.8 15.6 15.6 23.4 23.4
Electrical heating elements 3 3 3 6 3 9 9
Electrical heat element size, kW 2.6 5.2 2.6 2.6
11 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Gap Setting for Vibration Switch (VariableSpeed and Fixed-Speed Models)
18, 20 27, 30 35 40 50 60 80 125
Switch gap setting*, in. (mm)
0.015-0.025 (0.38-0.64)
0.025-0.035 (0.64-0.89)
0.030-0.040 (0.76-1.02)
0.020-0.030 (0.51-0.64)
0.025-0.035 (0.64-0.89)
0.013-0.015 (0.20-0.25)
0.009-0.011 (0.23-0.28)
0.006-0.008 (0.15-0.20)
* Gap setting should be made with “GO-NO-GO” type feeler gauge. Lower value must not trip switch. Upper value must trip switch.
After the machine has been properly installed, the vibration switch gap must be measured before conducting the Control Function Test. Locate the gap found between the vibration switch and the machine structure. Refer to Figures 4, 5, 6, 7 and 8. To check the gap setting of the switch, proceed as follows:
F232135 12 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 1

For 18, 20, 25, 27, 30 and 35 Pound Capacity Machines

1 Sump 3 Vibration Switch 2 Gap Distance 4 Switch Extension
13 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

For 40 and 50 Pound Capacity Variable-Speed and Fixed-Speed Machines

1 Sump 3 Vibration Switch 2 Gap Distance 4 Switch Extension
F232135 14 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

For 60 Pound Capacity Variable-Speed and Fixed-Speed Machines

1 Lower Bracket 4 Balance Bolt 2 Upper Bracket 5 Lock Nut 3 Vibration Switch 6 Gap Distance
15 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

For 80 Pound Capacity Machines

1 Switch Extension 3 Vibration Switch 2 Gap Distance
F232135 16 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

For 125 Pound Capacity Machines

1 Vibration Switch 3 Switch Extension 2 Gap Distance
17 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Variable-Speed and Fixed-Speed Models
Specification 20 30 35 40 50 60 80 125
Overall width, in. (mm) 26 (660)
Overall height, in. (mm) 42-7/8 (1089)
Overall depth, in. (mm) 29-13/16 (757)
Weight and Shipping Information
Net weight, lbs. (kg) 386 (175)
Domestic shipping weight, lbs. (kg) 424 (191)
Domestic shipping volume, ft3 (m3) 28 (0.8)
35 (1.0)
39 (1.09)
42.6 (1.19)
53 (1.5)
53 (1.5)
97 (2.7)
153 (4.3)
Export shipping weight, lbs. (kg) 476 (215)
Export shipping volume, ft3 (m3) 30.1 (0.86)
39.6 (1.11)
47.1 (1.32)
54.1 (1.51)
58.7 (1.67)
58.7 (1.67)
109.5 (3.1)
173 (4.8)
Cylinder diameter, in. (mm) 21 (533)
Cylinder depth, in. (mm) 13-3/4 (349)
Cylinder volume, ft3 (l) 2.76 (78.1)
4.19 (118)
5.76 (163.1)
6.34 (180)
8.18 (232)
9.00 (255)
12.96 (367)
19.24 (545)
Perforation size, in. (mm) 0.188 (4.76)
0.188 (4.76)
0.188 (4.76)
0.188 (4.76)
0.188 (4.76)
0.188 (4.76)
0.188 (4.76)
0.188 (4.76)
Perforation open area, % 17 23 17 17.5 18 18 27 17
Door opening size, in. (mm) 12 (305)
Height of door bottom above floor, in. (mm) 14-3/8 (365)
Average power used per cycle, kW-hr 0.05 0.07 0.20 0.34 0.37 0.21 0.40 0.60
Average HVAC load, Btu/hr 400 450 510 510 750 750 950 1200
F232135 18 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Variable-Speed and Fixed-Speed Models (Continued)
Specification 20 30 35 40 50 60 80 125
Number of motors in drive train 1
Drive motor power, HP (kW) 2 (1.5)
2 (1.5)
2 (1.5)
2 (1.5)
2 (1.5)
3 (2.2)
5 (3.7)
7.5 (5.6)
Gentle wash/reverse speed, RPM 29 27 26 26 24 24 22 27
Wash/reverse speed, RPM 52 48 46 47 43 43 40 37
Distribution speed, RPM 82 86 73 73 68 77 63 62
Low extract speed, RPM 366 343 328 328 307 307 280 260
Medium extract speed, RPM (Not available on Electronic Control models.)
534 500 478 478 447 447 408 380
High extract speed, RPM 685 641 613 614 573 574 524 485
Gentle wash centrifugal force, Gs 0.25 0.43
Wash/reverse centrifugal force, Gs 0.8
Distribution centrifugal force, Gs 2
Low extract centrifugal force, Gs 40
Medium extract centrifugal force, Gs 85
High extract centrifugal force, Gs 140
Vibration switch installed* Standard
Direct Steam Heating (Optional)
Steam inlet connection size, in. (mm)
Number of steam inlets 1
Steam required to raise bath water temperature 10°F (6°C), lbs. (kg)
0.92 (0.42)
2.1 (1.51)
2.09 (1.51)
2.8 (2.0)
3.6 (1.63)
4.1 (2.93)
6.8 (4.9)
1.31 (0.6)
2.69 (1.96)
2.84 (2.04)
3.6 (2.59)
5.5 (2.49)
6.0 (4.34)
8.9 (6.4)
Average steam use per cycle, bhp (kg) 0.54 (8.3)
0.73 (11.3)
1.4 (21.6)
1.43 (22.4)
1.8 (28.9)
2.32 (36.4)
2.93 (45.9)
4.5 (71)
Total electrical heating capacity, kW 7.8 7.8 15.6 15.6 23.4 23.4 31.2 N/A
Electrical heating elements 3 3 6 3 9 9 12 N/A
Electrical heat element size, kW 2.6 2.6 2.6 5.2 2.6 2.6 2.6 N/A
* Refer to Gap Setting for Vibration Switch (Variable-Speed and Fixed-Speed Models) section for specifications.
19 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT


18, 20, 25, 27, 30, 35, 40, 50, 60 AND 80 POUND CAPACITY MACHINES
1 Supply Dispenser 5 Hot Water Inlet 2 Input Power Block 6 Extra Inlet Valve 3 External Chemical Supply Signal Terminal Strip (OPL only)
7 External Chemical Supply Inlet (OPL only) 8 Vacuum Breaker 4 Cold Water Inlet 9 Drain Outlet
F232135 20 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Machine Capacity Dimensions
Dimensions 18, 20 25 27, 30 35 40 50 60 80
A 22-15/16 in. (583 mm)
23 in. (584 mm)
24 in. (610 mm)
26 in. (660 mm)
25-3/4 in. (654 mm)
26-3/8 in. (670 mm)
26-3/8 in. (670 mm)
30-5/8 in. (777 mm)
B 17-1/4 in. (438 mm)
17-1/4 in. (438 mm)
17 in. (432 mm)
19 in. (483 mm)
18 in. (457 mm)
18-1/4 in. (464 mm)
18-1/4 in. (464 mm)
21-5/8 in. (549 mm)
C 14-3/8 in. (365 mm)
14-3/8 in. (365 mm)
14 in. (356 mm)
16 in. (406 mm)
14-1/2 in. (368 mm)
13-1/2 in. (343 mm)
13-1/2 in. (343 mm)
17-3/4 in. (451 mm)
D 26 in. (660 mm)
26 in. (660 mm)
29 in. (737 mm)
30-1/8 in. (765 mm)
30-5/8 in. (778 mm)
34-1/16 in. (865 mm)
34-1/16 in. (865 mm)
41-1/2 in. (1054 mm)
E 25-5/8 in. (650 mm)
30 in. (762 mm)
30-5/8 in. (775 mm)
34 in. (864 mm)
36 in. (914 mm)
37-3/4 in. (959 mm)
38-3/4 in. (984 mm)
48 in. (1219 mm)
F 29-13/16 in. (757 mm)
34-3/16 in. (868 mm)
34-13/16 in. (884 mm)
38-1/8 in. (968 mm)
40-3/16 in. (1021 mm)
41-13/16 in. (1062 mm)
42-13/16 in. (1087 mm)
51 in. (1295 mm)
G 0 0 0 1-1/8 in. (29 mm)
1/2 in. (13 mm)
1/2 in. (13 mm)
1/2 in. (13 mm)
1/2 in. (13 mm)
H 42 in. (1062 mm)
45 in. (1143 mm)
45 in. (1143 mm)
47 in. (1194 mm)
47 in. (1194 mm)
49-15/16 in. (1268 mm)
49-15/16 in. (1268 mm)
56 in. (1422 mm)
I 12-1/2 in. (318 mm)
12-1/2 in. (318 mm)
15-1/4 in. (387 mm)
14-1/4 in. (362 mm)
15-7/16 in. (392 mm)
20-3/4 in. (527 mm)
20-3/4 in. (527 mm)
22-1/4 in. (572 mm)
J 11-1/2 in. (292 mm)
11-1/2 in. (292 mm)
14-3/4 in. (375 mm)
10-13/16 in. (275 mm)
14-7/16 in. (367 mm)
19-3/4 in. (502 mm)
19-3/4 in. (502 mm)
14-7/16 in. (378 mm)
K 3-1/2 in. (89 mm)
3-1/2 in. (89 mm)
3-3/4 in. (95 mm)
2-3/4 in. (70 mm)
3-13/16 in. (97 mm)
3-1/2 in. (89 mm)
3-1/2 in. (89 mm)
3-7/16 in. (87 mm)
L 34-1/2 in. (876 mm)
37-1/2 in. (952 mm)
37-11/16 in. (957 mm)
40-1/8 in. (1020 mm)
39 in. (990 mm)
41-1/2 in. (1054 mm)
41-1/2 in. (1054 mm)
44-1/2 in. (1130 mm)
M 5-3/4 in. (146 mm)
5-3/4 in. (146 mm)
5-7/8 in. (149 mm)
7-5/16 in. (186 mm)
5-1/2 in. (140 mm)
6-7/16 in. (163 mm)
6-7/16 in. (163 mm)
6-3/8 in. (162 mm)
N 4-1/2 in. (114 mm)
4-1/2 in. (114 mm)
4 in. (102 mm)
4-3/4 in. (121 mm)
4-3/4 in. (121 mm)
5 in. (127 mm)
5 in. (127 mm)
5-3/4 in. (146 mm)
O 2 in. (51 mm)
2 in. (51 mm)
2 in. (51 mm)
2 in. (51 mm)
3 in. (76 mm)
3 in. (76 mm)
3 in. (76 mm)
3 in. (76 mm)
P 36-3/16 in. (919 mm)
39-3/16 in. (995 mm)
38-15/16 in. (989 mm)
41-15/16 in. (1064 mm)
42-1/8 in. (1070 mm)
43-3/16 in. (1097 mm)
43-3/8 in. (1102 mm)
42-3/4 in. (1086 mm)
Q 38-1/2 in. (978 m)
41-1/2 in. (1054 mm)
41 in. (1041 mm)
41-15/16 in. (1064 mm)
43-3/16 in. (1097 mm)
45-1/2 in. (1156 mm)
45-1/2 in. (1156) mm)
50 in. (1270 mm)
R 1-3/16 in. (30 mm)
1-3/16 in. (30 mm)
1-3/16 in. (30 mm)
1-3/16 in. (30 mm)
1-3/16 in. (30 mm)
1-3/16 in. (30 mm)
1-3/16 in. (30 mm)
1-3/16 in. (30 mm)
S 3 in. (76 mm)
3 in. (76 mm)
3 in. (76 mm)
3 in. (76 mm)
3 in. (76 mm)
3 in. (76 mm)
3 in. (76 mm)
3 in. (76 mm)
21 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT


1 Dry Chemical Dispenser (Optional – OPL Models Only)
4 Hot Water Inlet 5 Liquid Chemical Inlet 2 Cold Water Inlet 6 Steam Inlet (Optional) 3 Extra Water Inlet (Optional) 7 Drain Outlet
A 40 in. (1016 mm) K 41 in. (1041 mm)
B 30-1/4 in. (768 mm) L 38-1/2 in. (978 mm)
C 29 in. (737 mm) M 33-1/2 in. (851 mm)
D 8 in. (203 mm) N 29-3/4 in. (756 mm)
E 48 in. (1219 mm) O 24 in. (610 mm)
F 50-1/2 in. (1283 mm) P 13 in. (330 mm)
G 56-3/4 in. (1422 mm) Q 4-7/8 in. (124 mm)
H 1 in. (25 mm) R 63-7/8 in. (1622 mm)
I 70-1/2 in. (1791 mm) S 64-7/8 in. (1648 mm)
J 44-1/2 in. (1130 mm) T 66-5/8 in. (1692 mm)
F232135 22 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

E
FRONT
A
D
B
U158M U158M
Machine Capacity Dimensional Clearances
Dimensions 18, 20 25 27, 30 35 40 50 60 80 125
A 2 in. (50 mm)
2 in. (50 mm)
2 in. (50 mm)
2 in. (50 mm)
2 in. (51 mm)
2 in. (50 mm)
2 in. (50 mm)
2 in. (50 mm)
24 in. (600 mm)
B 26 in. (660 mm)
26 in. (660 mm)
29 in. (737 mm)
30-1/8 in. (765 mm)
30-5/8 in. (778 mm)
34-1/16 in. (865 mm)
34-1/16 in. (865 mm)
41-1/2 in. (1054 mm)
48 in. (1219 mm)
C 1 in. (25 mm)
1 in. (25 mm)
1 in. (25 mm)
1 in. (25 mm)
1 in. (25 mm)
1 in. (25 mm)
1 in. (25 mm)
1 in.* (25 mm)
12 in. (300 mm)
D 16-3/8 in. (416 mm)
16-3/8 in. (416 mm)
19-1/4 in. (490 mm)
19-1/4 in. (490 mm)
22 in. (560 mm)
22 in. (560 mm)
22 in. (560 mm)
25 in. (635 mm)
26-1/4 in. (667 mm)
E 25-5/8 in. (650 mm)
29-7/16 in. (705 mm)
30-1/2 in. (775 mm)
34 in. (864 mm)
36 in. (914 mm)
37-1/2 in. (953 mm)
38-3/4 in. (984 mm)
51-5/8 in. (1311 mm)
56-3/4 in. (1441 mm)
F 12 in. (305 mm)
12 in. (305 mm)
12 in. (305 mm)
18 in. (457 mm)
12 in. (305 mm)
12 in. (305 mm)
12 in. (305 mm)
24 in. (610 mm)
24 in. (610 mm)
*For 80 pound models intended for standard mounting, clearance should be 6 in. (150 mm).
23 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

The machine must be anchored to a smooth, level surface so that the entire base of the machine is supported and rests on the mounting surface. (Do not support the machine on only four points.)
An elevated foundation must not exceed 8 inches (203 mm).
The floor must be 3500 psi minimum reinforced concrete set firmly in clean, compacted fill dirt.
Refer to Table 2 for foundation and anchoring requirements.
Anchoring
Installation Foundation
Anchoring
Bolt Diameter
Models Foundation
Floor Thickness
Method(s) Requirement
Thickness
Method(s)
Size (minimum)
2 Speed and Fixed-Speed (20-60 Models)
4 in. (102 mm)
4 in. (102 mm)
Direct-to-finished-floor, elevated base frame, or concrete foundation
5/8 in.
6 in. (152 mm)
6 in. (152 mm)
Direct-to-finished-floor or concrete foundation
J-bolt or mounting bolt
5/8 in.
80 Models 9 in. (229 mm)
6 in. (152 mm)
Direct-to-finished-floor or concrete foundation
3/4 in.
125 Models 12 in. (304 mm)
6 in. (152 mm)
F232135 24 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

P035I
1 Machine Base 2 Mounting Bolt Threads 3 Grouting 4 Bolt-Locator Fixture or Rebar Frame
25 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Refer to Table 3 and Table 4 for static and dynamic loads on the floor or foundation.
Specification 18, 20 25 27, 30 35 40 50 60
Static floor load, lbs. (kN)
476 (2.12)
549 (2.44)
653 (2.90)
804 (3.58)
873 (3.88)
1041 (4.63)
1015 (4.53)
Static pressure, lbs-ft2 (kN-m2)
104 (4.96)
103 (4.94)
106.3 (5.10)
113 (5.41)
123 (5.89)
117 (5.62)
115 (5.5)
Dynamic load, lbs. (kN)
296 (1.31)
420 (1.87)
427 (1.90)
581 (2.58)
987 (4.4)
860 (3.83)
1418 (6.3)
Dynamic pressure, lbs-ft2 (kN-m2)
64.4 (3.08)
79.3 (3.80)
69 (3.33)
82 (3.91)
139 (6.7)
97 (4.64)
161 (7.6)
Dynamic load frequency, Hz
8.75 9.00 8.00 7.83 7.80 7.50 7.50
Maximum moment about machine base, lbs-ft (kN-m)
565 (0.769)
832 (1.0)
847 (1.16)
1247 (1.6)
2118 (2.9)
1894 (2.4)
2470 (3.35)
Specification 20 30 35 40 50 60 80 125
Static floor load, lbs. (kN) 513 (2.27)
688 (3.01)
934 (4.1)
873 (3.88)
1136 (5.0)
914 (4.07)
1972 (8.8)
2316 (10.3)
Static pressure, lbs-ft2 (kN-m2) 112 (5.35)
112 (5.35)
132 (6.3)
123 (5.89)
128 (6.1)
103 (4.95)
144 (6.9)
145 (6.93)
Dynamic load, lbs. (kN) 512 (2.27)
7.55 (3.36)
979 (4.35)
1397 (6.25)
1428 (6.3)
2243 (9.98)
3500 (15.5)
Dynamic pressure, l bs-ft2 (kN-m2)
112 (5.35)
123 (5.88)
138 (6.60)
158 (7.6)
159 (7.5)
161 (7.6)
164 (7.84)
364 (17.4)
Dynamic load frequency, Hz 11.5 10.7 10.22 10.2 9.58 9.58 8.73 8.08
Maximum moment about machine base, lbs-ft (kN-m)
979 (1.33)
1510 (2.05)
2122 (2.7)
2410 (3.3)
3071 (3.9)
3138 (4.25)
5749 (7.2)
11,667 (14.7)
F232135 26 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 3 · 1123 (5) · Table 4

Before anchoring the machine, refer to Table 2 to determine the appropriate method of anchoring for the machine.
2-9/16 in. (65 mm)
U137I
H029I
The completed expansion bolt installation is shown in Figure 13.
2-9/16 in. (65 mm)
1 Washer 2 Locknut 3 Machine Base 4 5/8 in. (19 mm) Diameter Expansion Bolt
27 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

1-1/2 in. (38 mm)
NOTE: There are two different mounting bolt layouts which may be used for the 80 pound capacity machine. Refer to Figure 19. The bolt holes marked “A” are to be used for close mounting – machines installed with a 1 inch (25.4 mm) clearance between machines. The bolt holes marked “B” are to be used for standard mounting – machines installed with a minimum clearance of 8 inches (203 mm) between machines.
H031I
F232135 28 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

H033I
Figure 17 shows the completed J-bolt installation with grout.
1-1/2 in. (38 mm)
U139I
1 Foundation 2 Locknut 3 Machine Base 4 1/2 in. (13 mm) Machinery Grout 5 J-Bolt
29 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Metal templates are available at cost through Alliance Laundry Systems at (920) 748-3121. Refer to Table 5 for specific Part Numbers when ordering.
Machine Part No.
25 F608708
27/30 F631796
35 F608709
40 F0637047-00
50/60 F608710
80 F609692
125 F601862
F232135 30 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 5

26 in. (660 mm)
26 in. (660 mm)
2.68 in. (68 mm)
2.68 in. (68 mm)
20.66 in. (525 mm)
27.94 in. (710 mm)
30 in. (762 mm)
23.94 in. (608 mm)
31.75 in. (806 mm)
26 in. (660 mm)
34.88 in. (885 mm)
18.31 in. (465 mm)
27.69 in. (705 mm)
0.75 in. (19 mm)
2.56 in. (65 mm) 20.88 in. (530 mm)
0.75 in. (19 mm)
20.88 in. (530 mm)
2.56 in. (65 mm)
2.56 in. (65 mm)
2.56 in. (65 mm)
29 in. (737 mm)
34.06 in. (865 mm)
3.28 in. (83 mm) 3.28 in. (83 mm)
27.5 in. (700 mm)
2.75 in. (70 mm) 2.75 in. (70 mm)
23.5 in. (597 mm)
28.94 in. (735 mm)
31.5 in. (800 mm)
36 in. (914 mm)
37.5 in. (953 mm)
37.52 in. (953 mm)
46.88 in. (1191 mm)
18.44 in. (468 mm)
24.07 in. (611 mm)
30.02 in. (762 mm)
37.44 in. (951 mm)
23.88 in. (607 mm)
2.56 in. (65 mm)
2.03 in. (52 mm)
2.03 in. (52 mm) 30 in. (760 mm)
0.75 in. (19 mm)
0.75 in. (19 mm)
2.56 in. (65 mm)
50 POUND
CHM2020N
CHM2020N
*For close mounting, use mounting bolt pattern labeled “A”; for standard mounting, use “B.”
31 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT


0.75 in. (19 mm) 23.25 in. (591 mm) 23.25 in. (591 mm)
*For close mounting, use mounting bolt pattern labeled “A”; for standard mounting, use “B.”
F232135 32 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

26.4 in. (670 mm)
26.4 in. (670 mm)
2.87 in. (73 mm)
2.87 in. (73 mm)
2.87 in. (73 mm)
2.87 in. (73 mm)
20.66 in. (525 mm)
20.66 in. (525 mm)
27.94 in. (710 mm)
30.2 in. (767 mm)
23.94 in. (608 mm)
31.75 in. (806 mm)
26.2 in. (665 mm)
34.88 in. (885 mm)
18.31 in. (465 mm)
14.31 in. (363 mm)
27.69 in. (705 mm)
25.22 in. (640 mm)
1.13 in. (29 mm) 2.75 in. (70 mm) 20.88 in. (530 mm)
1.13 in. (29 mm)
20.88 in. (530 mm)
2.75 in. (70 mm)
2.75 in. (70 mm)
2.75 in. (70 mm)
30.5 in. (775 mm)
29.4 in. (747 mm)
3.44 in. (87 mm) 3.44 in. (87 mm)
23.63 in. (600 mm)
2.94 in. (75 mm)
23.5 in. (597 mm)
2.94 in. (75 mm)
32.5 in. (826 mm)
41.63 in. (1057 mm)
34.75 in. (883 mm)
28.94 in. (735 mm)
37.52 in. (953 mm)
31.2 in. (792 mm)
18.44 in. (468 mm)
20 in. (508 mm)
30.02 in. (762 mm)
31.88 in. (810 mm)
2.25 in. (57 mm) 26 in. (660 mm)
23.88 in. (607 mm)
2.75 in. (70 mm)
1.13 in. (29 mm)
1.13 in. (29 mm)
2.75 in. (70 mm)
2.25 in. (57 mm)
35 POUND
CHM2021N
CHM2021N
*For close mounting, use mounting bolt pattern labeled “A”; for standard mounting, use “B.”
33 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

23.63 in. (600 mm)
3.62 in. (92 mm)
34.5 in. (876 mm)
3.47 in. (88 mm)
27.5 in. (700 mm)
3.47 in. (88 mm)
32.5 in. (826 mm)
46.88 in. (1191 mm)
38.25 in. (972 mm)
41.63 in. (1057 mm) 36 in. (914 mm)
36 in. (914 mm)
20 in. (508 mm)
24 in. (610 mm)
37.44 in. (951 mm)
31.88 in. (810 mm)
2.38 in. (61 mm) 2.44 in. (62 mm)
26 in. (660 mm)
2.22 in. (56 mm) 30 in. (762 mm)
1.13 in. (29 mm)
30.88 in. (784 mm)
2.22 in. (56 mm)
34.5 in. (876 mm)
3.47 in. (88 mm)
27.5 in. (700 mm)
3.47 in. (88 mm)
38.9 in. (988 mm)
36 in. (914 mm)
46.88 in. (1191 mm)
24 in. (610 mm)
37.44 in. (951 mm)
2.22 in. (56 mm)
30 in. (762 mm)
2.13 in. (54 mm)
2.22 in. (56 mm)
CHM2022N
*For close mounting, use mounting bolt pattern labeled “A”; for standard mounting, use “B.”
F232135 34 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Factory-built elevated steel base frames are designed to meet the specifications of the 20-60 2 speed, F speed and A-control variable-speed model washer- extractor only. Refer to Figure 22.
H031I
1-1/2 in. (38 mm)
Installing With Elevated Base Frame
H032I
35 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232135 36 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

A concrete foundation pad may be constructed to elevate the machines. Refer to Figure 25, Figure 26 or Figure 27 for a typical concrete foundation installation.
18, 20, 25, 27, 30, 35, 40, 50 AND 60 POUND CAPACITY MODELS
1 Pad height must not exceed 8 in. (203 mm) 2 1 in. (25 mm) Minimum 3 4 in. (102 mm) Minimum
37 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT


COMPACTED FILL DIRT 18 in. (457 mm) DEPTH COMPACTED FILL DIRT 18 in. (457 mm) DEPTH
1 9 in. (229 mm) 3 47-1/2 in. (1207 mm) 2 6 in. (152 mm) 4 4 ft. 6 in. (1372 mm)

1 12 in. (305 mm) 3 48 in. (1219 mm) 2 6 in. (152 mm) 4 6 ft. (1829 mm)
F232135 38 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

39 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Use the supplied black rubber adapter and clamps to transition from the machine drain outlet to the two inch schedule 40 PVC plumbing (20, 25 and 30 models) and the three inch schedule PVC plumbing (40, 60 and 80 models).
Figure 28 and Figure 29 show typical drain trough and drain line installations.
Connect the drain outlet to a vented drain system using only a flexible connection. The drain system must be vented to prevent an air lock or siphoning.
If proper drain size is not available or practical, a surge tank is required. A surge tank along with a sump pump should be used when gravity drainage is not possible, such as in below-ground-level installations.

1 Drain Hose 4 Drain Tee 2 Drain Valve 5 Floor 3 Overflow Hose 6 Open Drain Trough

1 Drain Hose 4 Overflow Hose 2 Drain Valve 5 Vent Pipe 3 Drain Tee 6 Water Inlet Valve* * 1 foot (0.3 m) minimum between water inlet valve and vent pipe.
F232135 40 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Refer to Table 6 for capacity-specific drain information.
18, 20 25 27, 30 35 40 50 60 80 125
Drain connection size, OD
2.38 in. (60 mm)
2.38 in. (60 mm)
2.38 in. (60 mm)
2.38 in. (60 mm)
3.5 in.* (89 mm)
3.5 in.* (89 mm)
3.5 in.* (89 mm)
3.5 in.* (89 mm)
3.5 in.* (89 mm)
Number of drain outlets
1
20 gal-min (76 l-min)
25 gal-min (95 l-min)
25 gal-min (95 l-min)
35 gal-min (132 l-min)
50 gal-min (189 l-min)
50 gal-min (189 l-min)
50 gal-min (189 l-min)
50 gal-min (189 l-min)
70 gal-min (265 l-min)
Recommended drain pit size
1.80 ft3
2.36 ft3
2.50 ft3
3.14 ft3
4.52 ft3
4.52 ft3
4.52 ft3
5.90 ft3
(66.8 l)
(70.3 l)
(88.9 l)
* Also works with 3 inch OD PVC pipe if connected to inside of drain tee connector.
Number of Machines
Model
1 2 3 4 5
18, 20 2 in. (52 mm) 3 in. (76 mm) 3 in. (76 mm) 4 in. (102 mm) 4 in. (102 mm)
25 2 in. (52 mm) 3 in. (76 mm) 3 in. (76 mm) 4 in. (102 mm) 4 in. (102 mm)
27, 30 2 in. (52 mm) 3 in. (76 mm) 3 in. (76 mm) 4 in. (102 mm) 4 in. (102 mm)
35 3 in. (76 mm) 3 in. (76 mm) 3-1/2 in. (89 mm) 4 in. (102 mm) 4 in. (102 mm)
40 3 in. (76 mm) 4 in. (102 mm) 4 in. (102 mm) 4 in. (102 mm) 6 in. (152 mm)
50 3 in. (76 mm) 4 in. (102 mm) 4 in. (102 mm) 4 in. (102 mm) 6 in. (152 mm)
60 3 in. (76 mm) 4 in. (102 mm) 4 in. (102 mm) 4 in. (102 mm) 6 in. (152 mm)
80, 125 3 in. (76 mm) 4 in. (102 mm) 4 in. (102 mm) 6 in. (152 mm) 6 in. (152 mm)
41 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Suitable air cushions should be installed in supply lines to prevent “hammering.” Refer to Figure 30.
Connections should be supplied by a hot and a cold water line of at least the sizes shown in Table 8. Installation of additional machines will require proportionately larger water lines.
To connect water service to machine with rubber hoses, use the following procedure:
If additional hose lengths are needed, use flexible hoses with screen filters.
MW008J
MW008J
Model
Number
Supply Line Size
1 Water Supply Faucets 2 Air Cushions (Risers)
Main Hot/Cold
1 3/4 in. (19 mm) 1/2 in. (13 mm)
2 1 in. (25 mm) 3/4 in. (19 mm)
3 1-1/4 in. (32 mm) 1 in. (25 mm)
4 1-1/2 in. (38 mm) 1 in. (25 mm)
1 1 in. (25 mm) 3/4 in. (19 mm)
2 1-1/2 in. (38 mm) 1 in. (25 mm)
3 2 in. (50 mm) 1-1/4 in. (32 mm)
4 2 in. (50 mm) 1-1/2 in. (38 mm)
1 1-1/2 in. (38 mm) 1 in. (25 mm)
2 2 in. (50 mm) 1-1/2 in. (38 mm)
3 2 in. (50 mm) 2 in. (50 mm)
4 2-1/2 in. (70 mm) 2 in. (50 mm)
F232135 42 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 8

Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive.
DANGER
Hazardous Rotation Speed. Will cause serious injury when controlling AC inverter drive with a parameter unit, safety features are bypassed allowing basket to rotate at high speeds with the door open. Place large sign on front of machine to warn people of imminent danger.
Hazardous Voltage. Can cause shock, burn or death. Verify that a ground wire from a proven earth ground is connected to the lug near the input power block on this machine.
W361
Machines equipped with an AC inverter drive require a clean power supply, free from voltage spikes and surges. Use voltage monitor to check incoming power. The customer’s local power company may provide such a monitor.
Single-phase machines require a single-phase inverse- time circuit breaker. Three-phase machines and variable-speed machines require a separate, three- phase inverse-time circuit breaker to prevent damage to the motor by disconnecting all legs if one should be lost accidentally. Check the nameplate decal on the back of the machine. Refer to Table 9 through Table 16 in this section for model-specific circuit breaker requirements.
If input voltage measures above rated maximum voltage, ask the power company to lower voltage. For voltages above or below listed specifications, contact Customer Service or a distributor for buck/ boost transformer recommendation. Refer to Electrical Specification section.
If machine is intended for four-wire service, a neutral leg must be provided by power company.
If a delta supply system is used on a four-wire model, connect high leg to L3.
43 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Phase Adder
If three-phase service is unavailable for a 2 speed model and a Roto-Phase or other phase adder is used, connect artificial leg to L3 in input power junction box.
Connect machine to an individual branch circuit not shared with lighting or other equipment. Shield connection in a liquid-tight or approved flexible conduit. Proper conductors of correct size must be installed in accordance with National Electric Code or other applicable codes.
Two speed machines have thermal overload protectors in drive motor windings and a separate fuse for control circuit.
Use wire sizes indicated in the Electrical Specifications chart for runs up to 50 feet (15 m). Use next larger size for runs of 50 to 100 feet (15 to 30 m). Use two sizes larger for runs greater than 100 feet (30 m).
For variable-speed machines, the AC drive provides overload protection for the drive motor.
For personal safety and proper operation, the machine must be grounded in accordance with state and local codes. If such codes are not available, grounding must conform to the National Electric Code, article 250-95. The ground connection must be made to a proven earth ground, not to conduit or water pipes.
Do not connect ground to neutral (N-white wire) leg at terminal strip.
F232135 44 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT


B 110 – 120 60 1 2 15 20 12 4 N/A
C 380 – 415 50 3 4 4 15 14 2.5 14 15 14 2.5
D 220 – 240 50 3 3 5 15 14 2.5 24 25 10 6
E 220 – 240 50 1 2 10 20 12 4 42 45 6 16
F 440 – 480 60 3 3 4 15 14 2.5 16 20 12 4
H 380 60 3 3 4 15 14 2.5 13 15 14 2.5
J 200 50 3 3 5 15 14 2.5 24 25 10 6
O 208 – 240 60 3 3 5 15 14 2.5 24 25 10 6
Y 208 – 240 60 1 2 10 20 12 4 42 45 6 16
Q 200 – 240 50/60 3 3.8 3.8 15 14 2.5 N/A

C 380 – 415 50 3 4 4 15 14 2.5 15 20 12 4
D 220 – 240 50 3 3 6 15 14 2.5 24 25 10 6
E 220 – 240 50 1 2 10 20 12 4 42 45 6 16
F 440 – 480 60 3 3 4 15 14 2.5 16 20 12 4
H 380 60 3 3 4 15 14 2.5 14 15 14 2.5
J 200 50 3 3 6 15 14 2.5 20 25 10 6
O 208 – 240 60 3 3 7 15 14 2.5 25 30 10 6
Y 208 – 240 60 1 2 10 20 12 4 43 45 6 16
Q 200 – 240 50/60 3 3 4.8 15 14 2.5 N/A
45 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 9 · Table 10


C 380 – 415 50 3 4 5 15 14 2.5 26 30 10 6
D 220 – 240 50 3 3 7 20 12 4 43 50 6 16
F 440 – 480 60 3 3 5 15 14 2.5 26 30 10 6
O 200 – 240 60 3 3 7 20 12 4 43 50 6 16
Y 208 – 240 60 1 2 12 25 10 6 N/A
N 440 – 480 50/60 3 3 2.3 15 14 2.5 27.3 30 10 6
P 380 – 415 50/60 3 3 2.3 15 14 2.5 24 25 10 6
Q 208 – 240 50/60 3 3 5.9 15 14 2.5 43.4 45 6 16
T 200 – 240 50/60 1 2 5.9 15 14 2.5 N/A
X 200 – 240 50/60 1 or 3 2 or 3 5.9/5.9 15 14 2x2.5 3x2.5 N/A

C 380 – 415 50 3 4 5 15 14 2.5 26 30 10 6
D 220 – 240 50 3 3 7 20 12 4 45 50 6 16
F 440 – 480 60 3 3 5 15 14 2.5 29 30 10 6
H 380 60 3 3 3 15 14 2.5 25 30 10 6
J 200 50 3 3 7 20 12 4 38 40 6 16
O 208 – 240 60 3 3 7 20 12 4 45 50 6 16
Y 208 – 240 60 1 2 13.5 30 10 6 N/A
N 440 – 480 50/60 3 3 6 15 14 2.5 30 30 10 6
P 380 – 415 50/60 3 3 6 15 14 2.5 29 30 10 6
Q 200 – 240 50/60 3 3 5 15 14 2.5 48 60 6 16
X 200 – 240 50/60 1 or 3 2 or 3 11/11 15 14 2.5 N/A
F232135 46 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 11 · Table 12

Voltage Designation Standard Electric Heat
Full Load Amps
Circuit Breaker
Full Load Amps
Circuit Breaker
Voltage
Cycle
Phase
Code
Wire
AWG
mm 2
AWG
mm 2
2 Speed Models
C 380 – 415 50 3 4 6 15 14 2.5 39 50 6 16
D 220 – 240 50 3 3 12 20 12 4 64 70 4 25
E 220 – 240 50 1 2 15 30 10 6 37 40 8 10
F 440 – 480 60 3 3 6 15 14 2.5 39 50 6 16
J 200 50 3 3 10 20 12 3 x 4 N/A
O 208 – 240 60 3 3 10 20 12 4 64 70 4 25
Y* 208 – 240 60 1 2 15 30 10 6 37 40 8 10
N 440 – 480 50/60 3 3 4 15 14 2.5 41.6 45 8 10
P 380 – 415 50/60 3 3 4 15 14 2.5 36.5 40 8 10
Q 200 – 240 50/60 3 3 6.3 15 14 2.5 62.6 70 4 25
T 200 – 240 50/60 1 2 6.3 15 14 2.5 N/A
X 200 – 240 50/60 1 or 3 2 or 3 6.3/6.3 15 14 2x2.5 3x2.5 N/A
47 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 13

Voltage Designation Standard Electric Heat
Full Load Amps
Circuit Breaker
Full Load Amps
Circuit Breaker
Voltage
Cycle
Phase
Code
Wire
AWG
mm 2
AWG
mm 2
2 Speed Models
C 380-415 50 3 4 4 15 14 2.5 37 50 8 10.0
D 220-240 50 3 3 7 20 12 4.0 64 70 4 25.0
F 440-480 60 3 3 4 15 14 2.5 41 50 8 10.0
H 380 60 3 3 3 20 12 4.0 33 50 8 10.0
J 200 50 3 3 8 20 12 4.0 55 60 6 16.0
O 208-240 60 3 3 7 20 12 4.0 64 70 4 25.0
X 200-240 50/60 1/3 2/3 9 20 12 4.0 N/A
N 440-480 50/60 3 3 4 15 14 2.5 42 50 8 10.0
P 380-415 50/60 3 3 5 15 14 2.5 37 40 8 10.0
Q 200-240 50/60 3 3 6 15 14 2.5 65 60 6 16.0
X 200-240 50/60 1/3 2/3 10 20 12 4.0 N/A
F232135 48 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 14

Voltage Designation Standard Electric Heat
Full Load Amps
Circuit Breaker
Full Load Amps
Circuit Breaker
Voltage
Cycle
Phase
Code
Wire
AWG
mm 2
AWG
mm 2
Variable-Speed Models
N 440 – 480 50/60 3 3 4.5 15 14 2.5 42 45 8 10
P 380 – 415 50/60 3 3 4.5 15 14 2.5 37 40 8 10
Q 200 – 240 50/60 3 3 12.4 20 12 4 87.4 90 2 35
Voltage Designation Standard Electric Heat
Full Load Amps
Full Load Amps
Voltage
Circuit Breaker
Circuit Breaker
Code
Cycle
Phase
Wire
AWG
mm 2
AWG
mm 2
Variable-Speed Models
N 440 – 480 50/60 3 3 5.1 15 14 2.5 N/A
P 380 – 415 50/60 3 3 5.1 15 14 2.5 N/A
Q 200 – 240 50/60 3 3 7.9 25 10 6 N/A
49 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 15 · Table 16

Steam Requirements (Steam Heat Option Only)
If machine fails to operate after power is connected, proceed as follows:
Hot Surfaces. Will cause severe burns. Turn steam off and allow steam pipes, connections and components to cool before touching.
For mechanical timer, P-computer and S-computer models, control circuit fuse is located on center brace.
For machines equipped with optional steam heat, install piping in accordance with approved commercial steam practices. Steam requirements are shown in Table 17.
For EDC and V-computer models, dual control circuit fuses (one primary, one secondary) are in control module. A decal identifies fuse(s) and provides fuse-rating appropriate to that specific model.
For NetMaster models, circuit fuses are located on side of control box.
Steam inlet connection size
125 pound 3/4 in. (19 mm)
For A-control and B-control models, circuit fuses are located on the output board.
Number of steam inlets 1
Recommended pressure 30 – 80 psi (2.0 – 5.4 bar)
Maximum pressure 80 psi (5.4 bar)
F232135 50 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 17

Connection of External Liquid Supplies
18 – 80 Pound OPL Models
WARNING
C VALVE PANEL – REAR VIEW
CHM2002N
CHM2002N
Supply Dispensing
1 External Supply Hose Opening
Number of dry supply compartments
3 0 or 5 (optional)
Number of liquid supply connections (OPL only)
Liquid supply connection size 5/16 in. (8 mm)
5/8 in. (15.9 mm)
51 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT



Consult the supply vendor instructions for operational details about supply injections.
Refer to Figure 33 and Figure 34.
Machines connected to 200VAC provide L1 and L2 fused outputs rated at 3 amps which may be used to power 208 – 240VAC supply pumps.
Machines connected to 400VAC do not provide L1 and L2 outputs. An external power source must be provided to power the chemical supply pump.
Do not use L1 or L2 with the common line to deliver 120VAC to chemical injection supply pumps if the machine is equipped with a control transformer.
F232135 52 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Terminals SUPPLY 1 through SUPPLY 5 provide 120VAC or 240VAC fused at 500mA. Refer to decal at external supply terminal strip to determine whether washer-extractor provides 120VAC or 240VAC. These terminals may be used to provide signals to chemical injection supply system but must not be used to provide power to actual pump.

Consult chemical injection supply system instructions for operational details.

1 Strain Relief for Liquid Chemical Supply Lines 2 Supply Dispenser Lid 3 Dry Supply Insert 4 Dry Supply Cups 5 Four Way Water Valve 6 Supply Dispenser
1 Strain Relief for Liquid Chemical Supply Lines 2 Supply Dispenser Lid 3 Dry Supply Cups 4 Dry Supply Insert 5 Four Way Water Valve 6 Supply Dispenser
53 F232135 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

c. Close the door without locking it and attempt
to start the machine. The machine should not start with the door unlocked.
d. Close and lock the door and start a cycle.
Attempt to open the door while the cycle is in progress. The door should not open.
If the door lock and interlock are not functioning properly, call a service technician.
a. Open the loading door.
For coin-operated machines, press the round button on the door handle and turn the door handle downward.
For machines intended for use in on-premises laundries, press and hold the door-unlock button on the left side of the control panel. Press the round button on the door handle and turn the door handle downward.
b. Attempt to start the machine with the door
open. The machine should not start with the door open.
F232135 54 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Instalación
Montaje fijo en gabinete Consulte la página 61 para la identificación de
modelos
Guarde estas instrucciones para referencia en el futuro. (Si esta máquina cambia de dueño, asegúrese de que este manual vaya con la misma).
Pieza No. F232135R6
Junio 2005


I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.
Invia la prima domanda: risponderanno altri possessori o il nostro team.