SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. DIRECT VENT FIREPLACE BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEA SE KEEP THESE I.
2 FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIR O” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst.
T able of Contents 3 Safety Precautions........................................................................................................2 T able of Contents........................................................................................
4 DIRECT VENT ONLY: This type is identied by the prex DV . This appliance draws all of its air f or combustion from outside the dwelling, through a specially designed v ent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.
.
Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.
2. Start the pilot by pr essing the gas control knob and turning it to PILOT . While holding the gas control knob in, press the piezo ignitor sever al times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (see Figure 3).
8 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating E) T urn on all electrical power to the unit. NOTE: Check that all burner holes are lit. TO TURN GAS FIREPLACE OFF: Flip switch to OFF to turn off burners only .
Maintenance And Ser vice R OUTINE M AINTENANCE : At least once a year , run through the following procedures to ensure the system is clean and working properly . Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything.
10 Maintenance And Ser vice C LEANING D ECORATIVE S URFACES : P ainted and porcelain f aces should be wiped with a damp cloth periodically . If a plated f ace has been purchased, it should be unpacked/unwr apped carefully to avoid getting anything on the surface of the nish, including cleaners, polish and nger prints.
11 F UEL C ONVERSION : Maintenance And Ser vice TO BE INST ALLED BY A QU ALIFIED SERVICE A GENCY ONL Y Please read and understand these instructions before installing.
12 Maintenance And Ser vice b) Insert a 5 / 32 ” or 4 mm Allen wrench into the hexagonal key- way of the screw (see Figure 11), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt.
13 Maintenance And Ser vice Red o-ring is not visible Red o-ring is visible LPG Configuration 8. R einstall the burner , brick panels, log set, embers, and glass door . Also refer to S ECONDARY I NSTALLATION - I NSTALLING L OG S ET AND E MBERS in your Owner ’ s Manual.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y I NTRODUCTION : This section of the owner’s manual is for the use of qualied technicians only . Fireplace placement, hearths, facing, mantels, and venting terminations will be cov ered, as wel l as the gas and electric systems.
Mount the two framing mount brackets on each side and secure the replace to framing with screws or nails (ref er to Figure 16). The br ackets will al low for a ” (13 mm), ” (16 mm), ” (19 mm) thick nishing wall. The wall may be nished up to the replace facing with combustible material.
3" (76mm) 12" (305mm) 6" (152mm) 14" (356mm) T op of unit 3” (76mm) mantle 10" (254mm) mantle Combustible front face 3 / 4 " (19mm) facing board Figure 23. Combustible Mantel Clearances for Fascia or Insets. Initial Inst alla tion QUALIFIED INST ALLERS ONL Y 16 A shelf may be installed abov e the unit.
17 1 In accordance with the current CSA B149, Natur al Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFP A 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the r equirements of the gas supplier .
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y 18 Figure 25: Wire Spacers. it to the inner wall frame using four (4) 1” wood screws. If a wall is greater than 8” (203mm) in depth, the clearance above the ex must be 4” (111mm) 6.
Flue Pipe Adaptor W all Framing W all Thimble Fire Stop Exhaust 4" Flex Pipe Combusion Air 6 5 / 8 " Flex Pipe Wire Spacers Horizontal V ent T ermination 19 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Figure 27: Installation of Fireplace Horizontal Vent Kit.
EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct V ent GS starting collar in conjunction with Secure V ent, Direct - T emp, and Ameri V ent Direct venting systems. Use of these systems with the Direct V ent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance.
21 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y V ENTING : This replace has been tested and certied for use with SIMPSON DURA VENT DIRECT VENT T YPE “GS” PIPE FOR GAS STOVES , SECURIT Y CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, AMERICAN MET AL PRODUCTS AMERIVENT DIRECT and DIRECT - TEMP SELKIRK MET ALBESTOS .
V e n t R e s t r i c t o r P o s i t i o n 20’ (6.10m) 25’ (7.62m) 30’ (9.14m) 32’ (9.75m) 41 3 / 4 ” (106cm) from floor 0’ (0m) 0’ (0m) 15’ (4.57m) 15’ (4.57m) 17’ (5.18m) 5’ (1.52m) 5’ (1.52m) 10’ (3.05m) 10’ (3.05m) Figure 31.
23 W all framing Horizontal wall termination W all thimble fire stop Exhaust flex pipe Combustion air outer pipe Elbow Initial Inst alla tion QUALIFIED INST ALLERS ONL Y H ORIZONTAL T ERMINATION : NOTES: 1.
24 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Step 3. T o install the Round Support Box/W all Thimble in a at ceiling, cut a 10 inch (25.4 cm) square hole in the ceiling, centered in the hole dril led in Step 2. Frame the hole as shown in Figure 29.
25 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y STEP 5. Cut hole in the roof center ed on the small hole placed in the roof from Step 2. The hole should be of sufcient size to meet minimum requirements for Clearance to Combustibles, as specied.
NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (914 mm), to avoid excessive stress on the elbows, and possible separ ation. W all straps are a vailable for this purpose (see Figure 36).
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y I NSTALLATION O F E LECTRICAL W IRING F OR T HE O PTIONAL F AN K IT : Figure 39. Wiring Diagram For Gas Valve.
28 Initial Inst alla tion G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping ma y make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stov e is equipped with a certied exible pipe located on the right side of the unit terminating in a ” male NPT tting.
29 Figure 41: This is how the re box looks with only the grate and Optional Brick P anels in place. The burner has three (3) locator pins for the logs. Second ar y Inst alla tion L OG S ET AND E MBER I NSTALLATION : The placement of the logs is not arbitr ary .
Second ar y Inst alla tion Figure 44: The right log has two (2) holes in it that will rest over the two (2) locator pins pointed out in Figure 43. Figure 45: The front end of the right/center log has a notch in it that is to rest around the right/center post of the grate.
31 Second ar y Inst alla tion Figure 47: Once the logs are in place the embers can be placed onto and around the burner to create a realistic look. Bags of ceramic ber embers and rock wool are provided. The ceramic ber comes in chunks that are about 2 inches (5.
32 Second ar y Inst alla tion O PTIONAL C ERAMIC B RICK P ANEL I NSTALLATION : Baffle Ledge Turn off the gas control knob and allow the unit to cool. Please ensure that your ceramic panels have not been damaged.
Second ar y Inst alla tion QUALIFIED INST ALLERS ONL Y O PTIONAL F AN K IT I NSTALLATION : The optional fan is thermostatically controlled and it wi ll not operate if the appliance is cold. A few minutes after the appliance is lit and the v ariable speed control is set at a desired setting, the fan will automatically turn on.
Figure 56. Install Fan Control Box. Figure 57. Plug In Fan Kit. 34 Second ar y Inst alla tion Installation of Kit: 1. Ensure the appliance is turned off and cool. 2. Remo ve the bottom louv ers. 3. Place fan in lower area of unit behind the contr ols (see Figure 54).
T rouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for . The gas valv e may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degr ees above ambient temperature.
P ar ts List Reference Number Part Description Part Number 1 120°F Cer amic F an T emperatur e Sensor EC -001 2 Thermocouple EC -009 2 Spark Electrode with I gnitor Cable EC -011 2 Thermopile EC -012 2 Pilot Orice NG Threaded EC -019 2 Pilot Orice LP Threaded EC -020 2 Pilot Gasket EC -021 3 S .
P ar ts List - Options Reference Number Part Description Part Number 17 Brick Panels (set of 3) 50-926 18 Louvre Set - Brushed Antique Copper (set of 2) 50-951 18 Louvre Set - Brushed Nickel (set of 2.
38 P ar ts Diagr am .
W arr anty Sherwood Industries Ltd. offers a Limited Lifetime W arranty on this gas product. This Limited Lifetime W arr anty covers the appliance for a period of seven years from the date of installation. This warr anty applies only to the original owner in the original location.
40 Inst alla tion Da t a Sheet The following information must be recorded by the installer f or warr anty purposes and f uture ref erence. NAME OF OWNER: _________________________________________ ADDR.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Enviro DV36 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Enviro DV36 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Enviro DV36 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Enviro DV36 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Enviro DV36, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Enviro DV36.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Enviro DV36. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Enviro DV36 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.