IDEALLY I NSTALL IN T HE C ENTRE OF CEILIN G AT L EAST 3 00mm FROM L IGHT FITTINGS LOCATE IONISATION A LARMS AWAY FROM KITCHENS TO PREVENT NUISANCE ALARM S ENSURE L IVE MAINS IS CORRECTLY CONNECTED TO.
1.1 Installation Guide 2.
2. Alarm Removal SLIDE AL AR M OFF BA SE WI TH T HE S CREW DRIVER STILL IN SER TE D, PUSH TH E LO WE R HALF OF TH E ALARM AW AY F ROM THE SCRE WD RIVER, I N TH E DIRECTION OF THE ARROW ON THE COVER HO.
2. HOW MANY ALARMS TO INSTALL - CATEGORIES & GRADES - The advice here follows the guidance in British Standard BS 5839-Part 6: 2004 in general (for further information see the BS standard itself).
for dwellings where occupants may be at high risk (e.g. elderly) OPTIMUM PROTECTION LD1 Optimum Protection LD1: As LD2, but in addition Smoke or Heat Alarms should be located in all rooms and other areas of the dwelling. (apart from toilets or bathroom) Multi Storey Dwelling LD1 Heat Alarms located in: (Heat Alarms must be within 5.
for dwellings where occupants may be at high risk (e.g. elderly) OPTIMUM PROTECTION LD1 Optimum Protection LD1: As LD2, but in addition Smoke or Heat Alarms should be located in all rooms and other areas of the dwelling. (apart from toilets or bathroom) Multi Storey Dwelling LD1 Heat Alarms located in: (Heat Alarms must be within 5.
for dwellings where occupants may be at high risk (e.g. elderly) OPTIMUM PROTECTION LD1 Optimum Protection LD1: As LD2, but in addition Smoke or Heat Alarms should be located in all rooms and other areas of the dwelling. (apart from toilets or bathroom) Multi Storey Dwelling LD1 Heat Alarms located in: (Heat Alarms must be within 5.
2.2 Selecting Alarm Type 1 Optical Smoke Alarms are recommended due to their excellent response to smouldering fires. If there is likely to be problems with steam, contamination or dust build-up, or if there is significant risk of a fast burning clean fire an Ionisation Smoke Alarm should be fitted.
Improved Audibility The effectiveness of Category LD2 and LD3 systems can be significantly enhanced if an additional Smoke Alarm (interconnected) is installed in the master bedroom. This will help ensure that a responsible person will quickly be alerted to a fire and can arrange for an orderly evacuation of children and other vulnerable occupants.
Wall mounting of smoke alarms (only): If ceiling mounting is impractical, smoke alarms may be mounted on a wall, provided that: a) the top of the detection element is between 150mm and 300mm below the.
• Do not locate in insect infested areas . Small insects getting into the smoke detector chamber can cause intermittent alarms. Insects and contamination on the Heat Alarm sensor can increase its response time. 4. INSTALLATION The Alarm is designed to be permanently mounted, using it’s own built-in terminal block to connect it to the mains.
Note: BS 5839-6 2004 gives the folowing recommendations regarding the mains supply to be used in a Grade D system (The Ei141RC/146RC/161RC/166RC Smoke Alarms and Ei144RC/164RC Heat Alarms can be used in a Grade D system). The power supply for the Alarms should be derived from the public electricity supply to the dwelling.
We strongly recommend that you check for the following before connecting the alarm : • check for Live and Neutral using a two probe tester. • check for Live using a neon tester. • check that the Interconnect wire is NOT connected to Live, Neutral or Earth.
prevent air draughts affecting the smoke/heat entering the alarm. If the hole is too large or the alarm does not seal it, it should be sealed with silicone rubber or equivalent. 6. Replace the wiring cover. Check the alarm battery is connected (Ei141RC/144RC/146RC only).
In the UK it is recommended that the following coloured cores are used (for example with triple flat 6243Y cable). 230V supply Brown Neutral Grey - sleeved blue at terminations Interconnect Black The interconnect wire (minimum 0.75mm 2 cable) must be treated as if it was Live.
5. ACCESSORIES Alarm System Control Switch Ei1529RC: The Syst em Contr ol Switc h is recommended for systems with three or more Smoke / Heat Alarms. It a llo ws the user to perform the following functions from a remote location: LOCATE - If alarms sound press Locate to allow source of alarm to be identified.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Ei Electronics Ei141RC è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Ei Electronics Ei141RC - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Ei Electronics Ei141RC imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Ei Electronics Ei141RC ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Ei Electronics Ei141RC, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Ei Electronics Ei141RC.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Ei Electronics Ei141RC. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Ei Electronics Ei141RC insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.