TRS 3064 Installation, Operation and Maintenance of the Airflex@ Timing Rotorseal and Cam Limit Switch Revised: Feb. 1, 1982.
1.0 Operation Throughout this manual, there are a number of Hazard Warnings that must be read and understood in order to prevent possible personal injury and/or damage to the equipment. Carefully read these warn- ings. They are included to protect you! 1.
Figure 1 illustrates the cams assembled in the timing section of both devices and their relationships. 1 Cam No. 2 Cam Insert No. 3 Cam No. 4 Cam insert No.
Cam No. 3 (28 and 28A) monitors the effective- ness of the press braking system at the top of the stroke. When cam No. 3 is positioned according to Paragraph 2.3, deviations in stopping position greater than + 15” from top dead center will be detected.
2.1.2. To a) b) c) d) e) f) g) h) i) j) mount the timing rotorseal: Make sure that the air tube “O” rings (2) are in place. Install the plastic insert (37A) in the head of the drive screw (37). Install drive screw. Tighten the screw, being careful not to distort the end plate (36).
Before mounting the timer, check to be sure its direction of rotation corresponds to that of the shaft. Fasten the flange to the shaft with lockwashers and cap screws. Refer to appropriate paragraph and mount second timer. W iring instructions are given in Paragraph 2.
m) Retighten the jam nuts (30) and repeat Steps “f”, “g” and “h”. n) Repeat this procedure as necessary to ob- tain the desired stopping position. 2.3.2 Long Operation: This feature is provided so an adjustment can be made to extend the LS4 open time and accommodate presses with long strokes and/or slow crankshaft speeds.
Breaker Point Opening Gap: This gap is preset at the factory on new units at time of assembly. A gap setting of .040” to .050” must be maintained at all times. The opening gap must be checked regularly and reset when required. To inspect for proper opening gap: a) b) c) d) e) h) i) j) k) Position the crankshaft at top dead center.
o) P) q) r) s) t) u) v) w) Align No. 5 cam with previously establish- ed top stop mark by rotating cam adjusting knob. Maintain No. 5 cam alignment by holding adjusting knob. Rotate No. 3 cam so that indicator groove lines up with the fiber cam follower on LS3 breaker point.
.
Item No. - 6. 20. 22. 23. 24. 25. 26. 27. 28. 28A 29. 30. 31. 32. 33. 33A 34 38. 40. 41. 42. 45. 46. 47. Part No. Description 302276 159 x 41 139 x 12 See table C See table C 201854 See table C 201869.
FOOT MOUNTED CAM LIMIT SWITCH Part No. for Optional Cam No. 3 (Item No. 28A), is as follows: 203002 (For clockwise and clockwise 30” dwell) 203087 (for c’clockwise and c’clockwise 30” dwell) Eaton Corporation Airflex Division Cleveland, Ohio 44144 PWNTED IN u.
PDF form at Form ML-31 8 Revised September 3, 1997 Eaton Cor poration Airflex Division 9919 Clinton Road Cleveland, Ohio 44144 Printed in U.S.A. EAT ON PROD UCT WARR ANTY Subject to t he c ondit io ns.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Eaton TRS 3064 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Eaton TRS 3064 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Eaton TRS 3064 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Eaton TRS 3064 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Eaton TRS 3064, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Eaton TRS 3064.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Eaton TRS 3064. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Eaton TRS 3064 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.