Manuale d’uso / di manutenzione del prodotto QuickScan QD2100 del fabbricante Datalogic
Vai alla pagina of 28
QuickScan TM i QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Quick Reference Guide.
Datalogic AD C, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 © 2008 - 2013 Datalogic, Inc. An Unpublished Work - All rights reserved .
Quick Reference Guide i Datalogi c ADC, Inc. QUICKSCAN TM PRODUCT SERIES END USER LICENS E AGREEMENT Notice to End User: The Datalogi c Product y ou have acquir ed contains embedded Software, which is integral to the product 's operation.
ii QuickScan TM i receipt or use of the source cod e to any Sof tware . 2.2 End User shall not co py , modify , deco mpile, di sassemb le, re v erse engi- neer , or ot herwise reprodu ce or reman uf a.
Quick Reference Guide iii responding to End User's pr oblem repor ts accordi ng to Datalog ic's standard assistance pract ices. Dat alogic do es not w arran t that the product wil l meet End.
iv QuickScan TM i HAS BEEN ADVISED OF THE POSSIBILITY OF SU CH DAMAGES . 9. Government Restricted Right s; International Use. 9.1 Use, duplic ation, or disclosure of th e Softwa re by the U. S. Go vernment is subject to the restrictio ns for computer software developed at private expe nse as set f orth in the U .
Software Product Policy Quick Reference Guide v Software Product Policy Datalogic r eserves the right to ship its pr oducts with the latest versio n of software/firm - ware available. This provid es our customers with the very latest in Datalogic software technology .
vi QuickScan TM i NO TES.
Connect/Disconnect Cable Quick Reference Guide 1 Connect/Disconnec t Cable Con nect Host Interface Keybo ard Wedge Inter f ace RS-232 Inter face USB Inter face IBM 46xx Interface 1 2.
2Q u i c k S c a n TM i Aim and S can 3 012345 012345 65° 65°.
Parts of the Im ager Quick Reference Guide 3 Parts of the Imager Scanning Modes The imager can operate in one of several scanning modes: Tr i g g e r S i n g l e — When the trigger is pulled, scanni.
4Q u i c k S c a n TM i Always On — No trigger pull is required to read a barcode. Scanning is continually on. If the trigger is pulled, the reader acts as if it is in Trigger Single Mode. Double Read Timeout 1 prevents undesired multiple reads while in this mode.
Scanning Modes Quick Reference Guide 5 Scanning Modes — continued Scan Mode = Flashing Scan Mode = Alwa ys On Scan Mode = Stand Mode Scan Mode = T rigger Object Sense.
6Q u i c k S c a n TM i T roubleshooting Prob lem Possible Cause Possib le Solutions Nothing happens when the scan button is pulled. No power to the imager. Check system power . Ensure power supply is connected. Interface or po wer cables are loose. Ensure all cable connec- tions are secure.
LED and Beeper Indicati ons Quick Reference Guide 7 LED and Beeper In dications The imager’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. A “Green Spot” also lights to indicate a good read. The tables below list these indi- cations.
8Q u i c k S c a n TM i Programmi ng Ba rcode s For your convenience, this gu ide includes the programming barcodes required to configure th e imager for use with different interface (terminal/host) types. See the Product Reference Guide (PRG) for more complete in- formation about programming an d configurable features.
Programming Barcodes Quick Reference Guide 9 RS-232 Interface To use an RS-232 interface, scan the barcode for the desired RS-232 host typ e. Select RS-232 Standard Select RS-232 Wincor Nixdor f Selec.
10 QuickScan TM i USB Inte rface The imager attaches directly to a USB host, or a powered USB hub, and is powered by it. No addition al power supply is re- quired. When using a USB interface, the imager auto-detects the USB and defaults to the HID keyboard interface.
Programming Barcodes Quick Reference Guide 11 Keyboard W e dge Interface To use a Keyboard Wedge interf ace, scan the barcode for the desired keyb oard type. Select KBD-A T (A T , PS/ 2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard K ey Encoding) Select KBD-A T -NK (IBM A T PS2 with standard ke y encoding b ut without e xternal kbd.
12 QuickScan TM i Keyboard W edge Inter fa ce — c ontinued Select KBD-XT (PC/XT w/Standard K ey Encod ing) Select KBD-IBM-3153 (f or IBM T er minal 3153) Select KBD-IBM-M (f or IBM T erminals 31xx, .
Ergonomic Recommendations Quick Reference Guide 13 Ergonomic Recommend ations • Reduce or eliminate r epetitive motion • Maintain a natural position • Reduce or eliminate ex cessive force • Ke.
14 QuickScan TM i Hin wei s Benutzen Sie nur eine von Datalogic genehmigte Stromver- sorgung. Die Modelle erfordern eine Stromquelle der Klasse II oder III mit einer Leistungsbegrenzung (LPS).
Replacing the Sc an Windo w Quick Reference Guide 15 Replacing the Sc an Window If the Scan Window becomes scratched, broken or contaminat- ed with heavy dust, fix it by removing the Nose Boot and clean- ing or installing a new window . Datalogic offers a re placement window as an orderable accessory.
16 QuickScan TM i Imager Labeli ng Labels are shown here to illustrate their location only. Please view the labels on your product for actual details. W aste Electrical and Electronic Equipment ( WEEE) Statement English For information about the disposal of Waste Electrical and Elect ronic Equipment (WEEE), please refer to t he website at www.
Imager Labeling Quick Reference Guide 17 In order to obtain serv ice under the Factory Wa rranty, Cus tomer mus t notify Data logic of th e claimed def ect before the expiration o f the applicab le Warranty period and obtain fro m Datalogic a return autho rization n umber (RMA) for return of th e product to a designate d Datalogic service cen- ter.
18 QuickScan TM i QuickScan i QD2100 China RoHS PART 部件名称 Lead (Pb) Mercur y (Hg) Cadmium (Cd) Hexavalen t Chromium (Cr(VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE.
DECLAR ATION OF CO NFORMIT Y EC-82 Rev.:1 Pag.: 1 di 1 Datalogic ADC, Inc. 959 Terry Street Eugene, Oregon 97 402 USA La presente dichiarazione di conformità è rilasciata sott o la res ponsa bilità es clusiv a di Data logic A DC, Inc . per: This Declaration of Conform ity is issued under the sol e responsibility of Datalogic ADC , Inc.
Datalogic ADC, Inc. 959 Terry Street | Eugen e | OR 97402 | USA Telephon e: (1) 541-683-5 700 | Fax: (1 ) 541-345- 7140 820045914 (Rev. F) August 2013 www.datalogic.com © 2008 - 2 013 Datalogic, Inc. • All r ights reser ved. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Datalogic QuickScan QD2100 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Datalogic QuickScan QD2100 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Datalogic QuickScan QD2100 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Datalogic QuickScan QD2100 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Datalogic QuickScan QD2100, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Datalogic QuickScan QD2100.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Datalogic QuickScan QD2100. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Datalogic QuickScan QD2100 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.