Manuale d’uso / di manutenzione del prodotto GREEN LIGHT GLPX-HSW-FT del fabbricante Crestron
Vai alla pagina of 16
GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Introduction CRESTRON GREEN LIGHT EXPRESS power swi tching cabinets com e pre-configured with GLXP swit ching modules already i nstalled. The cabinets onl y require installat ion and wiring of feed and load circuit s.
Power Switching Cabinet GLPX- HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Physical Description This section shows the dim ensions of the CRESTR ON GREEN LIGHT EXPRESS power switching cabi nets.
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Dimensions of GLPX-HSW-FT-8 , -12, -16 Power Switc hing Cabine ts (Inte rnal View) 23 1/2" (597 mm) 18 15/16” (481 mm) (2X) .
Power Switching Cabinet GLPX- HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Dimensions of GLPX-HSW-FT-20, -24, -28, -32 Powe r Switching Cabinets (Front, Side and Bottom View) 16 1/8” (409 mm) 39 5/8” (1.
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Dimensions of GLPX-HSW-FT-20, -24, -28, -32 Powe r Switching Cabine ts (Inte rnal Vie w) 2 1/8” (55 m m) (2X) Ø 5/16” (Ø 8 mm).
Power Switching Cabinet GLPX- HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Installation Observe the following wh en installing the cabinet: • The cabinet must be mounted by a licensed electrician in accordance w ith all national and local codes. Refer to the diagram below for specific requirem ents.
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Wiring NOTE: All wiring must be installed in accordance w ith all local and national electrical codes. NOTE: Refer to the torque settings specifi ed on pages 8 and 9. CRE GLXP low profile switchi ng modules instal led.
Power Switching Cabinet GLPX- HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Feed-Through and Load Wiring (Section A) ION: Bypass jumpers are provided on each output to allo w testing and to prot ect the m odules during CAUT installation. The ju mper shor ts the L and SW terminals so that the load circuit is energized when is on.
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Control Wiring (Section B) The bottom of the cabinet contains Cresnet connections for interfacin g to the rest of the Crestron control system and a power port to provide an alternat e source of 24 volt power to the m odules.
Power Switching Cabinet GLPX- HSW-FT CRESTRON GREEN LIGHT ® EXPRESS NET Port Wiring When wiring the supplied NET connectors for connect ion to a Crestron control sy stem or other device on t he Cresnet network, use Crestron certifie d wire such as CRESNET-NP or CRESNET-P.
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Testing Ma Ligh To t and t rele NO ram ma y change the settings if the Override m ode is not enabled . nual Control ting modul es can be manually controlled from the front panel. oggle the output between off and on, ta p the appropriate ON/OFF button.
Power Switching Cabinet GLPX- HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Problem Solving Troubleshooting ituations. If further assistance i s required, please TROUBLE The following table provides correct ive action for possible t r ouble s contact a Crestron customer service representative.
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Appendix A: Setting Module Net IDs The following pro cedure will normally be performed by an authorized Crestron representative as p.
Power Switching Cabinet GLPX- HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Appendix B: Specifications Specifications for the GLXP m odules are listed i n the following table.
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT This page is intentionally left blank. Installation Guide – DOC. 6888B GREEN LIGHT ® EXPRESS Power Sw itching Cabinet GLPX-HSW-FT.
Power Switching Cabinet GLPX- HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandi se may be returned for credi t, ex change or service without pri or authorization from CRESTRON. To obtain warranty service for CRESTRON product s, contact an authorized CRESTRON dealer.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Crestron GREEN LIGHT GLPX-HSW-FT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Crestron GREEN LIGHT GLPX-HSW-FT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Crestron GREEN LIGHT GLPX-HSW-FT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Crestron GREEN LIGHT GLPX-HSW-FT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Crestron GREEN LIGHT GLPX-HSW-FT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Crestron GREEN LIGHT GLPX-HSW-FT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Crestron GREEN LIGHT GLPX-HSW-FT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Crestron GREEN LIGHT GLPX-HSW-FT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.