FuturePlus® Systems Corporation FBDIMM INTERPOSER PROBE FS2343 Users Manual For use with Agilent T ec hnologies Logic Analyzers Revision 1.2 F uturePlus is a trademark of FuturePlus Systems Corp orat.
2 How to reach us....................................................................................................................... 4 Product Warranty ...............................................................................................
3 Symbols .................................................................................................................................. 17 Preferences ...............................................................................................
4 How to reach us For Technical Support: FuturePlus Systems Corporation 36 Olde English Road Bedford NH 03110 TEL: 603-471-2734 FAX: 603-471-2738 On the web http://www.futureplus.com For Sales and Marketing Support: FuturePlus Systems Corporation TEL: 719-278-3540 FAX: 719-278-9586 On the web http://www.
5 Product W arranty Due to wide variety of possible custo m er targe t implementations, the FS2343 FBDIMM Interposer prob e has a 30 d ay acceptance period by the custom er from the date of receipt.
6 Software License Agreement IMPORTANT - Please read this license agreeme nt carefully before opening the media envelope. Rights in the software are offer ed only on the condition t hat the customer agrees to all terms and conditions of the license agreement.
7 Introductio n Thank you for purchasing the FuturePlus Systems F S 2343 FBDI MM Interposer Logic Analyzer Probe. We think you will find the FS2343, along with your Agilent Technologies Logic Analyzer, a valuable tool for helping to chara cterize and d eb ug your FBDIMM- based systems.
8 FS2343 Probe Description The FS2343 FBDIMM Interposer Probe is based on the “Lo gic An alyzer Interface (LAI) Mode” of the Advanced Memory Buffer chip used on Fully Buffered DIMMs.
9 Probe Technical Feature Su mmary • Quick and easy conne ction betwee n a 240 pin FBDIMM connector and Agilent 1690x Logic Analyzers. • Complete and accurate state analysi s of Primary South and Secon dary No rthbound FBDIMM traffic as seen by the AMB in LAI mode on the Interposer probe.
10 Probe Set-up Probe overview The FS2343 Interposer probe uses an AMB device in “LAI” mod e and provides the appropriate FBDIMM conn ection s to an “inter posed” FBDIMM device for it to op erate within the memory bus. The LAI mode perform s 2 functions.
11 The other orientation for the probe is wit h a 90 degree bend to either it’s front (A MB) or back side. There are right angle b ra ckets provid ed to kee p the probe in this position along with the associated nyl on hardware. It is our recomm endation that the interposed FBDIMM be placed in the probe before the prob e is bent over.
12 Signal Assignments on Prob e Pods There are signal connectio ns for up to 6 different logic analyzer adapter cable s (E5378A). This prov ides the user with some flexibilit y in terms of which signals they connect to based on the type of analysis that is needed, e.
13 FBDIMM Paddle Board Connector layout Software Requirements For state analysis you must have versio n A. 02.99.00 or later Agilent OS installed on the 1690x frame. Version A.02.99.00 contains the capability for SMBus control of the prob e through the 16753/4/5/6 or 16950 cards.
14 This is what the FS2343 probe u ser sho uld use to guide them in connecting ada pter cables to analyzer card pods. If the pod connections need to be chang ed, it can be done using the Edit Probes feature, which is shown below. The Refe rence De sig nator field should be J9 through J15 from the paddle card.
15 Configuration File Labels The configuration files provided with the probe software have a number of labels defined that are useful in providing rapid identific ation of sampling position, DRAM, an d Channel Command activity in the state listing. They c an also be use d as triggers for the logic analyzer.
16 TID – single Transaction identifier bit, used in Write Config. Register Channel Command. SD - Status delay, 2 bit field used in Sync command. Allows return status data to be delayed by up to 3 frames. EL0s - The EL0s bit indicates the chan nel sh ould transition from the L0 state to the L0s state for exactly 42 frames.
17 Symbols Terms used in the FBDIMM proto col are def ined under labels that are referred to as symbols. Symbols can be used in d efining triggers or for use in default store qualifications.
18 Channel Commands - A, B, C labels Symbol Symbol Value Channel NOP 0000 000x Sync 00000 001x Soft Channel Reset 0000 010x reserved 0000 011x Read Config Reg 0000 100x Write Config Reg 0000 101x DRAM.
19 Example using symbol “Act ivate” in a trigger Preferences The Preferences option is used to set the proto col decoder for failover mode. If the Southbound or Northboun d is in failover mode, the preference s mu st be set accordingly.
20 Below is a picture of the preference options.
21 SM (SMBus) Contro l Paddle card Settings The FS2343 probe is designed so that AMB/LA I device control can be either from the 16900 logic analyzer and t he Probe Control applic ation software resid ent there, or from another FS2343 probe (slave mode).
22 Event Bus Cabling The Event Bus bits, Evbus[0:3], from other probes can be daisy chained acro ss m ultiple probes in order to provide cro s s probe cont rol of other probes. There are 2 EV cable connectors on each probe and both connectors are wired in parallel so that eithe r can be used.
23 Setup The Set-up screen provides control ove r basic probe use. • The probe Configuration se tup button all ows the user to select when they want to set up the parameters within the AMB. The choices are al way s after link training, before link training only when n eede d, or always before link training.
24 SB Commands This allows Match or Mask control over any 3 Command pattern s e ntered by the user in either hex or binary format. Furthermore, each of 3 pat terns can be searched for in either Command Slot A, B or C, or all three patterns in all 3 Command Slots.
25 Store Qualificat ion This section controls the op eration of the Qual Flag, Qual Stop Delay, and Qual Period Delay. It allows the user to select from 32 di fferent events for the definition of Qual Start and Qual Stop. These settings control the st ate of the Store_qual flag for non -filtered frames.
26 Trigger Events This capability allows the Probe user to define each of the AMB’s logic a nalyzer Triggers [0:10] to be set to one of 32 different event cond itions seen by the AMB. It is important to note that not all LAITrig[0:10] signals are available to the logic ana lyzer.
27 Event Bus This feature controls the operation of the Event Bus signals EV[0:3] whi ch can be use d for communication and triggering betwe en probes in an FBDIMM Channel.
28 State Analysis Operation For proper state analysi s the user mu st cho o se the correct configuration file to load depending on what type of analysis is d e sired, such as analyzing both North bou nd and Southbound activity or just one dire ction .
29 After the probe has been configured, the tri gger fo r the analyzer m ust be set. To set the trigger for the analyzer go to the setup menu bar and select “Advanced Trigger”. On the next window that pops up specify what you want the analyzer to trig ger on.
30 State Display Offline Analysi s Offline analysis allows a user to be able to analyze a trace offline at a PC so it fre es up the analyzer for another person to use the analyzer to captu re data.
31 For data from a 16900 analyzer, open the .ala file usin g the File, Open menu selections and browse to the desired .ala file. After clicking “next” you must browse for the fast binary data file you want to import. Once you have located the file and clicked start import, the data should a ppea r in the listing.
32 After the decoder has loaded, select Pre f eren ce s from the overview screen and set the preferences to their correct value in order to decode the trace prope rly.
33 Appendix FS2343 Paddle Sig nal to Lo gic Ana lyzer Conne ctor and Ch annel Mappi ng The following table shows how the FS2 343 Pro be connects FBDIMM AMB sig nals to the logic analyzer pods and channel s through the 100 pin Samtec connectors. Note that the configuration files described earlie r use various combination s of these Pod connections.
34 Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name NB_L4_B5_11 Odd D9 43 44 Even D.
35 J11 Pods 1(Odd) and 2 (Even) Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name Gr.
36 Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name NB_L11_B1_7 Odd D13 59 60 Even .
37 J15 Pod 1(Odd) Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name Ground 1 2 Groun.
38 Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name TRIGGER1 Odd D14 63 64 Even D14.
39 J12 Pods 1(Odd) and 2 (Even) Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name Gr.
40 Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name Ground 61 62 Ground TRIGGER1 Od.
41 J10 - Pods 1(Odd) and 2 (Even) Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name .
42 Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name Ground 61 62 Ground SB_L6_B2_8 .
43 J13 Pods 1(Odd) and 2 (Even) Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name Gr.
44 Signal name/Logical Signal Name Logic A nalyzer channel number SA MTE C Pin number SA MTE C Pin number Logic A nalyzer channel number Signal Name/Logical Signal name SB_L4_B0_6 Odd D13 59 60 Even D.
45 General Inf ormation This chapter provides addi tional reference information including th e cha racteristics and signal connections for the FS2343 FBDI MM Interposer Probe. The following operating characteristics are not specificatio ns, bu t are typical operating characteristics.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Agilent Technologies FS2343 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Agilent Technologies FS2343 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Agilent Technologies FS2343 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Agilent Technologies FS2343 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Agilent Technologies FS2343, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Agilent Technologies FS2343.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Agilent Technologies FS2343. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Agilent Technologies FS2343 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.