Manuale d’uso / di manutenzione del prodotto CARRIER ASPASICCA012 del fabbricante Carrier
Vai alla pagina of 24
® Owner's Manual US Air-cooled, Prepackaged Automatic Standby Generators Models: ASPASICCA007 (6 kW NG, 7 kW LP) ASPASICCA012 (12 kW NG, 12 kW LP) ASPASICCA015 (13 kW NG, 15 kW LP) © Not intended for use as Primary Power in place of utility or in life-support applications.
INTRODUCTION Thank you for purchasing this model of the Carrier product line. This model is a compact, high performance, air-cooled, engine-driven generator designed to automatically supply electrical power to operate critical loads during a utility power failure.
Table of Contents Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators Introduction ........................ Inside Front Cover Read This Manual Thoroughly .............................. iFC Contents ....................................................
SAFETY RULES IMPORTANT SAFETY INSTRUCTIONS Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators SAVE THESE INSTRUCTIONS - The manufacturer suggests that these rules for safe operation be copied and posted near the unit's installation site. Safety should be stressed to all operators and potential operators of this equipment.
IMPORTANT SAFETY INSTRUCTIONS Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators SAFETY RULES /A ELECTRICAL HAZARDS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock.
o • o GENERAL NFORMATON Section 1 -- General Information Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators _Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regulations.
Section 1 -- General Information Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators GENERAL INFORMATION 1.4 THE GENERATOR Figure 1.1 - 7 kW, Single Cylinder GH-410 Engine Exhaust Enclosure Oil Data Dipsiick ', Decal , , ', , Conirol _0 /' C / GFCI .
o • o GENERAL NFORMAT ON Section 1 -- General Information Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators 1.5 SPECIFICATIONS 1.5.1 GENERATOR Model Rated Max.
Section 1 -- General Information Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators GENERAL INFORMATION Should the primary fuel need to be changed to LP gas, the fuel system needs to be reconfigured. See Section 1.9 for instructions on reconfiguration of the fuel system.
GENERAL INFORMATION Section 1 -- General Information Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators 1.10 BATTERY INSTALLATION Fill the battery with the proper electrolyte fluid if necessary and have the battery fully charged before installing it.
Section 2 -- Operation Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators OPERATION Servicing of the battery is to be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
OPERATION Section 2 -- Operation Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators 2.3 AUTOMATIC TRANSFER OPERATION To select automatic operation, do the following: 1. Make sure the transfer switch main contacts are set to their UTILITY position, i.
Section 2 -- Operation Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators OPERATION 2.5 MANUAL TRANSFER OPERATION 2.5.1 TRANSFER TO GENERATOR POWER SOURCE To start the generator and activate the transfer switch manually, proceed as follows: 1. Set the generator's AUTO/OFF/MANUAL switch to OFF.
OPERATION Section 2 -- Operation Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators NOTE: The exerciser will only work in the AUTO mode and will not work unless this procedure is performed. The exerciser will need to be reset every time the 12-volt battery is disconnected and then reconnected.
Section 3 -- Maintenance Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators POS__ iNSTALLATiON STAR.UP ADJUSTMENTS Figure 3.1 - Generator Control Panel ' EX EEHNAL I 0UTLET FUSE z _ GFCI 75A ...... _ C_RGU_T AUTO OFF MAN BREAKER 12 VDC SYST O i i • i i SET EXERCISE ACCESSORY TIME OUTLET 75A MAX 3.
MAINTENENANCE Section 3 -- Maintenance Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators Figure 3.4 - Oil Drain Hose and Filter Low OH Switch HighT_ _Switch ¢ OH FHter 3.4 CHANGING THE OIL FILTER Change the engine oil filter as follows: 1. With the oil drained, remove the old oil filter by turning it counterclockwise.
Section 3 -- Maintenance Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators MAINTENENANCE Figure 3.7 - Setting the Spark Plug Gap SET PLUG GAP AT 0.76 mm (.030 inch) - 7 kW 0.508 mm (.020 inch) - 12 kW & 15 kW 3.7 BATTERY MAINTENANCE The battery should be inspected per the "Service Schedule," Section 4.
MAINTENENANCE Section 3 -- Maintenance Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators Figure 3.8 - Coofing Vent Locations [] D t °_ WARNING /dR INTAKF _The exhaust from this product gets extremely hot and remains hot after shutdown. High grass, weeds, brush, leaves, etc.
Section 4 -- Service Schedule Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators SERVICE 4.1 SERVICE SCHEDULE ATTENTION: It is recommended that all service work be performed by the nearest Carrier Dealer.
TROUBLESHOOTING Section 5 - Troubleshooting Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators 5.1 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION The engine will not crank. 1. Fuse blown. 1. 2. 2. 3. 3. 4. 4. * 5. 5. Loose, corroded or defective battery cables.
Section 6 -- Warranty Carrier Air-cooled 7 EW, 12 EW and 15 EW Generators CARRIER "TWO YEAR" LIMITED WARRANTY FOR "PREPACKAGED EMERGENCY AUTOMATIC STANDBY GENERATORS" For a period .
Section 6 - Warranty Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The California Air Resources Board (CARB) and Generac Power Systems, Inc. (Generac) are pleased to explain the Emission Control System Warranty on your new engine.
Section 6 - Warranty Carrier Air-cooled 7 EW, 12 EW and 15 EW Generators EMISSION CONTROL SYSTEM WARRANTY Emission Control System Warranty (ECS Warranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines.
® PART NO. 0F6902 CATALOG NO. OMASPAS07-2 REV. * (6/01/05) PRINTED IN U.S.A..
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Carrier CARRIER ASPASICCA012 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Carrier CARRIER ASPASICCA012 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Carrier CARRIER ASPASICCA012 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Carrier CARRIER ASPASICCA012 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Carrier CARRIER ASPASICCA012, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Carrier CARRIER ASPASICCA012.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Carrier CARRIER ASPASICCA012. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Carrier CARRIER ASPASICCA012 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.