1 Section 61245201L1-5, Issue 3 61245201L1-5C FNID and T200 FNID Fractional T1 Network Interface Device Installation and Maintenance CONTENTS 1. GENERAL ............................................................................ 1 2. INSTALLATION ...
2 Section 61245201L1-5, Issue 3 61245201L1-5C With the exception of the physical dimensions of the units, the FNID and T200 FNID units are functionally identical. The FNID terminates local loop DSL signals originating from the Central Office (CO) unit and transforms the DSL signal into fractional T1 signals to be delivered to the customer.
3 Section 61245201L1-5, Issue 3 61245201L1-5C 3. CONNECTIONS All connections of the FNID are made through card edge connectors. Table B gives the card edge pin assignments for the FNID circuit pack.
4 Section 61245201L1-5, Issue 3 61245201L1-5C 5. CONTROL PORT OPERATION The FNID provides a faceplate-mounted DB9 connector that supplies an RS-232 interface for connection to a controlling terminal. The pinout of the DB9 is illustrated in Figure 4. The terminal interface operates at data rates from 2.
5 Section 61245201L1-5, Issue 3 61245201L1-5C From the Main menu the following screens can be accessed. 1. Current System Status 2. Performance History 3.
6 Section 61245201L1-5, Issue 3 61245201L1-5C A measure of signal quality for each HDSL loop is displayed in graphic form on the bottom right and left of the screen.
7 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 5. Introductory Menu Screen ADTRAN 901 Explorer Boulevard Huntsville, Alabama 35806-2807 For Information or Technical Support, Normal Support Hours ( 7am - 7pm CST ) or Emergency Support Hours ( 7x24 ) Voice Toll Free: 800.
8 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 7. Current System Status Screen FT1-DP CURRENT SYSTEM STATUS FNID NETWORK (DSL) ELAPSED TIME 00:08:18 CUSTOMER (DSL) ---------------------- -------.
9 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 9. Loopback Options Screen LOOPBACK OPTIONS FT1-DP FNID _____ _____ | | | | | | | | —-->| | | |<—- | | | | NET | |<===================.
10 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 11. Provisioning Options Screen PROVISIONING ___________________________________________________ ______________________ | | | | PROVISIONS CURRENT SETTINGS | HARDWARE SETTINGS | | ------------------------------------------ | ----------------- | | 1.
11 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 13. DSL Deployment Guidelines 6. DSL DEPLOYMENT GUIDELINES The ADTRAN FT1 DSL system is designed to provide Fractional DS1-based services over loops designed to comply with Carrier Service Area (CSA) guidelines.
12 Section 61245201L1-5, Issue 3 61245201L1-5C 7. TROUBLESHOOTING PROCEDURES Table E is a troubleshooting guide for the FNID. 8. MAINTENANCE The ADTRAN FNID requires no routine maintenance. In case of equipment malfunction, use the faceplate Bantam jack connectors to help locate the source of the problem.
13 Section 61245201L1-5, Issue 3 61245201L1-5C Loop Interface: Modulation Type ................................................. 2B1Q Mode .................................................................... Full Duplex, Echo Cancelling Number of Pairs .
A-1 Section 61245201L1-5, Issue 3 61245201L1-5C Appendix A FT1 Loopbacks 1. GENERAL This Appendix is an overall reference to the loopback capabilities of the ADTRAN Fractional T1 system. Included in this Appendix is a description of the FT1 loopbacks and the methods for activating the FT1 loopbacks.
A-2 Section 61245201L1-5, Issue 3 61245201L1-5C There is one loopback available to the FT1 Repeaters. The FT1 Repeater Network loopback is a digital loopback toward the CO as shown in Figure A-4. The loopbacks are initiated by the DDS latching loopback codes for NEI Position 1 (N1000001) for FT1 #1 or NEI Position 2 (N100001) for FT1 Repeater # 2.
A-3 Section 61245201L1-5, Issue 3 61245201L1-5C 3. LOOPBACK ACTIVATION/DEACTIVATION This section describes loopback activation and deactivation methods for the ADTRAN Fractional T1 system. Loopback activation and deactivation is controlled with the push-button located on the front panel, through craft interface, or latching loopback codes.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il ADTRAN T200 FNID è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del ADTRAN T200 FNID - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso ADTRAN T200 FNID imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul ADTRAN T200 FNID ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il ADTRAN T200 FNID, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del ADTRAN T200 FNID.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il ADTRAN T200 FNID. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo ADTRAN T200 FNID insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.