Manuale d’uso / di manutenzione del prodotto SLC-5 U-BR1TE III del fabbricante ADTRAN
Vai alla pagina of 14
Section 61102040L4-5, Issue 2 61102040L4-5B 1 1. GENERAL This practice provides installation and maintenance information for the ADTRAN SLC-5 U-BR1TE III w/ PWR and DDS Loopbacks (U-BR1TE III).
Section 61102040L4-5, Issue 2 61102040L4-5B 2 • Loopback release in response to TIPs generated from the network direction per TR62310. • Remap all subsequent DS0 DP loopback codes into respective eoc loopbacks to loopback respective downstream U-Repeaters, TRISDN elements, and U-BR1TES when optioned for 1B+D, or 2B+D.
Section 61102040L4-5, Issue 2 61102040L4-5B 3 C A U T I O N C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. The U-BR1TE III will function with any ISDN 2B1Q U-interface that is ANSI T1.601 compliant.
Section 61102040L4-5, Issue 2 61102040L4-5B 4 NOTE When the U-BR1TE III is optioned for B1 or B2, the SLC-2000 slot must be provisioned for D only. If the U-BR1TE III is optioned for 2B, then the SLC-2000 slot must be provisioned for B1+D. Physical Requirements The U-BR1TE III occupies one physical slot in the SLC-5 or SLC-2000 channel bank.
Section 61102040L4-5, Issue 2 61102040L4-5B 5 e p y T e c i v r e S e c i v r e S n o i t p On o i t p O n o i t p O n o i t p On o i t p O 1 - 1 W S ) 1 B () 1 B ( ) 1 B ( ) 1 B () 1 B ( 2 - 1 W S ) .
Section 61102040L4-5, Issue 2 61102040L4-5B 6 Figure 5 displays the position switch settings at ISDN network locations. Figure 5. Position Switch Settings at Network Locations for ISDN Applications 2-.
Section 61102040L4-5, Issue 2 61102040L4-5B 7 Figure 6. SLC-5 U-BR1TE III IDSL/DDS Circuit Diagram 4W DS0 DP or OCU DP T1 T1 D4 AB C D E D4 RT 4W DS0 DP or DCS 2-Wire Local Loop 2-Wire Local Loop 4W D.
Section 61102040L4-5, Issue 2 61102040L4-5B 8 Front Panel Features The RJ-45 jack allows front panel test access for local or downstream loopbacks. The address select knob (SW3) determines which element is being looped back. Table 3 lists the loopback options.
Section 61102040L4-5, Issue 2 61102040L4-5B 9 To initiate a point-to-point test, perform the following: 1. Connect the DS0 digital tester to the RJ-45 jack. 2. Configure the test set for Near Logic and 64kbps. 3. Select the desired test direction and bearer channel using the address select knob.
Section 61102040L4-5, Issue 2 61102040L4-5B 10 When the U-BR1TE III operation is normal, the ADR7 position of SW1 does not have a function. NOTE This test option is only available on power up of the U-BR1TE III.
Section 61102040L4-5, Issue 2 61102040L4-5B 11 DS0 DP Loopback eoc Remapping Upon receipt of subsequent DS0 DP loopback codes when the D channel is disabled, the U-BR1TE III remaps the subsequent DS0 DP loopback sequences into the respective ISDN eoc loopback messages.
Section 61102040L4-5, Issue 2 61102040L4-5B 12 Remote End Initiated LBK Tests The U-BR1TE supports loopbacks generated from the IDSL OCU-R which allow testing to be performed without coordination with the CO or test center.
Section 61102040L4-5, Issue 2 61102040L4-5B 13 Figure 11. IDSL/DDS Trouble Codes MOS 9Ah Channel Bank Open 2-wire Loop DSU IDSL OCU-R U-BR1TE Customer Premises ASC 9Eh Channel Bank ASC 9Eh Open 4-Wire.
Section 61102040L4-5, Issue 2 61102040L4-5B 14.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il ADTRAN SLC-5 U-BR1TE III è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del ADTRAN SLC-5 U-BR1TE III - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso ADTRAN SLC-5 U-BR1TE III imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul ADTRAN SLC-5 U-BR1TE III ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il ADTRAN SLC-5 U-BR1TE III, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del ADTRAN SLC-5 U-BR1TE III.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il ADTRAN SLC-5 U-BR1TE III. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo ADTRAN SLC-5 U-BR1TE III insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.